Description
1. Product Presentation
The disposable electrosurgery pencil Ref. F4798SE/TEF from FIAB is the single-use solution your operating theatre or minor surgery room needs for procedures requiring clean cutting, reliable haemostasis and surgical smoke control. Manufactured by FIAB SpA (Vicchio, Florence, Italy), this monopolar handle combines manual cut and coagulation push-buttons, universal Valleylab-type connector, 300 cm cable and an F4046/TEF blade electrode with non-stick Teflon coating, all integrated with a suction system for evacuating the smoke generated during electrosection.
Each unit is sterile and single-use, ready to open at the time of the procedure, eliminating the risk of cross-contamination and the costs of cleaning and re-sterilisation. It is supplied in a box of 10 individually packaged units, an ideal format for operating theatre supplies, clinics and institutional purchasing.
2. Technical explanation
In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends high-frequency current through the pencil to the active electrode (the blade mounted in the handle), which concentrates the energy at the point of contact with the tissue; the circuit is completed through the neutral or dispersive plate placed on the patient. Depending on the selected waveform, the effect is cutting, coagulation or mixed.
This handle incorporates manual control with push-buttons that allow cut and coagulation to be activated without releasing the instrument. The F4046/TEF blade electrode, in surgical-grade stainless steel with Teflon (PTFE) coating, minimises the adherence of carbonised tissue and maintains constant cutting performance throughout the procedure. Its 2.38 mm (3/32″) shaft is the industry standard for electrode holders. The Valleylab-type connector guarantees compatibility with most electrosurgical generators on the market (Medtronic/Covidien and compatible), and the integrated suction system allows surgical smoke to be evacuated at the point of generation, improving field visibility and reducing staff exposure.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F4798SE/TEF |
| Manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Disposable monopolar electrosurgery pencil (handle) with push-buttons and suction system |
| System | Monopolar, cut and coagulation |
| Activation | Manual push buttons (cut / coagulation) |
| Connector | Valleylab type |
| Cable length | 300 cm |
| Electrode | F4046/TEF blade with Teflon (PTFE) coating |
| Electrode size | Ø 2.38 mm |
| Suction system | Yes (surgical smoke evacuation) |
| Sterility | Sterile, single-use |
| Packaging | box containing 10 single units |
| Units per box (web) | 10 |
4. Equivalences and Cross-References
The reference F4798SE/TEF is the original catalogue designation of manufacturer FIAB within the range of disposable push-button pencils with Valleylab connector and F4046/TEF electrode, to which it adds the suction system (vacuum system). No equivalence table validated by the manufacturer and cross-referencing this exact configuration with 1:1 codes from other brands has been found in verified sources; before any substitution, each field must be checked: electrode (type and coating), shaft diameter (2.38 mm), cable length, generator connector type, suction system, sterility and presentation.
| Manufacturer / Family | Reference | Relationship level | Observations |
|---|---|---|---|
| FIAB – disposable push-button pencil with smoke evacuator (F4046/F4050 blade, 300 cm, box of 10 units) | F4797/SE | Comparable by family (same range with smoke evacuator) | Same pencil platform with suction system; the blade differs (standard F4046/F4050 versus F4046/TEF with Teflon). |
| FIAB – disposable push-button pencil, F4046 blade, 320 cm cable, Valleylab connector (box of 50 units) | F4798 | Comparable by family (not interchangeable) | Without suction system and without Teflon coating; different cable length and presentation. |
| FIAB – disposable rocker-type pencil with F4046/TEF blade, 320 cm cable, Valleylab connector (box of 50 units) | F4795/TEF | Comparable by category | Rocker activation and without suction system. |
Consult our technical-commercial department before using any equivalence in tenders or brand substitution.
5. Selection tips and variants of interest
If your priority is to reduce tissue adherence and maintain tip cleanliness during long dissections, the F4046/TEF blade with Teflon coating on this model is the right choice; its suction system adds surgical smoke evacuation at the point of work. Always verify that your generator has a Valleylab-type socket: for equipment of another standard (Erbe, 4 mm, 3.2 mm) consult the reusable adapters from the FIAB range (F4830–F4838) or the specific connector variants.
Within the FIAB family of disposable pencils, you may consider the F4798 (push-button, F4046 blade, without suction) if you do not need smoke evacuation, or the version with evacuator F4797/SE. As complementary accessories, the sterile holster F4545 and the sterile tip cleaner F7520 are recommended. It is a sterile single-use product: do not re-sterilise or reuse. For institutional volumes, supply agreements or tenders, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.