Description
1. Commercial Introduction
The metallic neutral plate Ref. 30566 is the reusable return (neutral) electrode that your monopolar electrosurgical unit needs to work safely and professionally. Made of metal (Italy), it guarantees a low-density return path for high-frequency current, reducing the risk of burns at the point of contact with the patient. It is supplied without cable: it must be combined with the plate cable Ref. 30560, which is purchased separately and reused between patients. It is the natural replacement part for Diatermo equipment that incorporates the flat MB metallic plate.
2. Technical Explanation
In any monopolar electrosurgical procedure, the radiofrequency current that exits through the active electrode must return to the generator via a controlled path. The metallic neutral plate fulfils this function: placed over a well-irrigated muscular area away from the surgical field, it collects the return current homogeneously and avoids energy concentrations that could damage tissue. As it is a reusable metal plate without cable, connection to the generator is made via the plate cable Ref. 30560, which has a connector compatible with Diatermo MB series and the rest of the electrosurgical range. For optimal and safe performance, it should be applied to dry, intact, hairless skin, always verifying proper skin-plate contact before activating the equipment.
3. Technical Specifications
The plate is presented as a reusable metallic return electrode, without cable, for use with the plate cable Ref. 30560 (included in other references of the range as an accessory for Diatermo MB 300D and MB 400D).
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | Z12010980 |
| GMDN | 11500 |
| EAN | 8033638322253 |
4. Equivalences and Cross-References
No official equivalence table validated by the manufacturer cross-referencing reference 30566 with identical codes from other brands has been found in reliable sources; any substitution must be validated case by case with our technical department. Within the range itself, the flat MB metallic plate with cable (Ref. 30564) is the variant that incorporates the cable, and the flexible steel-rubber plates (Refs. 30555 and 30556, 120 x 210 mm, autoclavable) also require the cable Ref. 30560. For rubber plates with bipartite REM system, we offer Ref. 30574 (20 x 15 cm), which uses cable Ref. 30575.
5. Selection tips and variants of interest
Check that your electrosurgical unit is compatible with the connection of cable Ref. 30560, the same one used by Diatermo MB series and equipment that includes flexible steel plate. If you prefer a plate with the cable already incorporated, consider Ref. 30564 (flat MB metallic plate with cable). For greater anatomical adaptability, the autoclavable flexible steel-rubber plates (Refs. 30555 and 30556) serve the same purpose with the same cable 30560. Check the condition of the metallic surface after each use, clean the plate following the manufacturer’s instructions and replace it if there are any cracks, deformations or loss of conductivity. For volume orders or special B2B conditions, consult our technical-commercial team at Cahnos.






Reviews