We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Paediatric disposable foam electrosurgical plate (return electrode), 148 x 90 mm (72 cm²), without REM system, 300 cm cable and Valleylab-type connection — box of 25 units (Ref. F7805PW/V)

50,31 €

Paediatric foam electrosurgical plate, Ref. F7805PW/V, with an active surface area of 72 cm² (148 x 90 mm), without REM system, integrated 300 cm cable and Valleylab-type connection, presented in a box of 25 units with individual packaging. The hydrogel adhesive on a polyethylene foam backing ensures anatomical adaptation to the paediatric patient, low contact impedance and uniform current distribution at the return point during monopolar electrosurgery. Single-use, non-sterile and latex-free product, indicated for operating theatres and ambulatory surgery with Valleylab-type pin generators without requiring a split plate.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7805PW/V

Description

Paediatric foam return electrode with Valleylab-type connection

The paediatric foam electrosurgical plate (Ref. F7805PW/V) is the essential neutral return electrode for completing the monopolar circuit of any high-frequency electrosurgery unit when operating on paediatric patients. Measuring 148 x 90 mm with an active surface area of 72 cm², it features an integrated 300 cm cable with a Valleylab-type connection, making it directly usable with generators that use this plug standard without requiring a split plate.

It is supplied in a box of 25 units with individual heat-sealed packaging that protects the conductive hydrogel until the moment of use: the consumption format chosen by hospitals, clinics and ambulatory surgery centres that require a reliable, consistent supply with permanent stock for their surgical scheduling.

How the return plate works and why it is important

In any procedure using a monopolar electrosurgical unit, the high-frequency current exits through the active electrode (handle or pencil), passes through the patient’s tissue and must return to the generator via a low current-density path. The neutral plate collects this current in a controlled manner: if contact is incorrect or the surface area is insufficient, the current density at the return point increases and, with it, the risk of thermal burn to the patient.

This plate is constructed with polyethylene foam backing and conductive hydrogel adhesive, which favours adaptation to the paediatric patient’s body contour and uniform skin contact. It belongs to the non-REM system series: it does not activate the generator’s return monitoring control (REM), so it must be used with conventional equipment without requiring a split plate, always selecting the lowest possible energy level. The 300 cm cable with Valleylab-type connection offers freedom of plate placement on the patient during the procedure.

Technical specifications

Characteristic Value
Reference / SKU F7805PW/V
Product type Disposable return plate (electrode) for monopolar electrosurgery
Population Paediatric
Measurements 148 x 90 mm
Active surface 72 cm²
Support Polyethylene foam
Conductive adhesive Hydrogel
Safety system Without REM (does not activate the generator’s REM control)
Cable length 300 cm
Connection Valleylab type
Use Single-use (disposable, non-sterile)
Latex-free Yes
Presentation Box of 25 units with individual packaging
Regulatory classification CE medical device

Paediatric range of the foam family (148 x 90 mm)

All references share the same foam backing and hydrogel adhesive; the difference lies in the REM system and the method of connection to the generator.

Reference Measurements Active surface REM Cable Connection
F7805P 148 x 90 mm 78 cm² No No TAB (tabs)
F7805PW/V (this product) 148 x 90 mm 72 cm² No 300 cm Valleylab
F7820P 148 x 90 mm 72 cm² Yes No TAB (tabs)
F7820PW/V 148 x 90 mm 72 cm² Yes 300 cm Valleylab

Equivalences and cross-references

There is no official equivalence table validated by the manufacturer that cross-references this reference with codes from other brands. The comparisons shown below are functional comparisons verified against official documentation from each cited manufacturer (Nissha catalogue and Medtronic website) and should not be treated as 1:1 interchangeable without validation from the technical department.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Nissha Medical Technologies (SWAROPLATE) NON-Split Diathermy Pad, Children, Valleylab-NONREM connector 1262H / 6000840N (1262H-SWARO-V1-8-96) Comparable by category (not interchangeable 1:1) Non-split plate (without REM) for children (> 5 kg and < 15 kg), polyethylene foam backing (PE foam), hydrogel adhesive and Valleylab-NONREM connector with cable. The dimensions differ (144 x 90 mm vs. 148 x 90 mm) and the total surface area (115 cm² vs. 72 cm² active surface). Code and attributes verified in the manufacturer’s official catalogue.
Medtronic / Covidien (Valleylab) Valleylab™ REM PolyHesive™ II Patient Return Electrode paediatric/infant with cable E7510-25 (box of 25) Comparable by category (not interchangeable 1:1) Return plate for paediatric/infant patients (< 13.6 kg / 30 lb) with integrated 2.7 m (9 ft) cable and Valleylab-type connector. The monitoring system differs (REM/split plate vs. without REM), the substrate (PolyHesive™ II adhesive hydrogel vs. polyethylene foam) and the cable length (2.7 m vs. 300 cm). Code verified on the official Medtronic website and in authorised distribution catalogues.

Although the cited products coincide in function (return without REM control, paediatric population, Valleylab-type connector and single-use), they differ in substrate, exact dimensions, active surface area or monitoring system, so they are not 1:1 interchangeable. Other homologous families in the sector that should be evaluated with their technical data sheet in hand before any substitution: paediatric neutral plates from AESCULAP (B. Braun), Skintact series from Leonhard Lang, BOWA Medical, EMED and GIMA; always checking field by field: dimensions, active surface area, hydrogel type, REM system, physical connector and compatibility with the installed generator.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.

Selection tips and variants of interest

  • Check the connector on your electrosurgical unit: this reference F7805PW/V requires a Valleylab-type socket and does not activate the generator’s REM control, so it is suitable for conventional equipment without requiring a split plate.
  • If you prefer a cable-free plate with tab connection (TAB), the equivalent option in the same size is the F7805P (148 x 90 mm, 78 cm², without REM), which can be used with the reusable cables F7902 (universal 6.3 mm jack), F7903 (Valleylab type) or F7904 (for Erbe), reducing the cost per procedure.
  • For generators equipped with a REM system, the alternative with return control in the same size is the F7820PW/V (148 x 90 mm, 72 cm², with REM, 300 cm cable and Valleylab connection) or the F7820P (TAB connection).
  • Other populations without REM: adults with F7805W/V (202 x 101 mm, 132 cm², 300 cm cable, Valleylab) or F7805 (TAB connection); neonates with F7805N (88 x 74 mm, 36 cm², TAB).
  • To expand compatibility, the adapters F4828 (from Valleylab-type connection to 4 mm plug) and F4829 (to 6.3 mm plug) can be used.
  • Instructions for use: always apply to dry, intact, hair-free skin, on a well-perfused muscular area away from pacemakers, metal implants or bony prominences. Check the integrity of the individual packaging and the expiry date before each use. Do not reuse or cut the plate: it is a single-use, non-sterile product.

Additional information

Material

Polyethylene foam backing with conductive hydrogel adhesive

Measurements

148 x 90 mm

Active surface

72 cm²

Safety system

Without REM (does not activate the generator's REM control)

Cable length

300 cm

Connection

Valleylab type

Use

Single-use (disposable, non-sterile)

Presentation

Box of 25 units with individual packaging

Compatibility

Electrosurgical generators with Valleylab-type socket without requiring a split plate (REM system)

Regulatory classification

CE medical device

Reference

F7805PW/V

Product type

Disposable return plate (electrode) for monopolar electrosurgery

Support

Polyethylene foam

Adhesive

Conductive hydrogel

Tipo paciente

Paediatric

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Paediatric disposable foam electrosurgical plate (return electrode), 148 x 90 mm (72 cm²), without REM system, 300 cm cable and Valleylab-type connection — box of 25 units (Ref. F7805PW/V)”

Your email address will not be published. Required fields are marked *