Description
1. Commercial Introduction
Disposable electrosurgical plates are the return electrode (neutral plate) essential for completing the monopolar circuit of your electrosurgical unit. This version for adult patients incorporates solid gel adhesive and is supplied without cable, allowing the connection cable Ref. 30563 to be reused between patients and optimising the cost per procedure. Ideal for operating theatres, major ambulatory surgery, minor surgery clinics and veterinary clinics working with electrosurgical generators with tabbed plates.
2. Technical explanation
In monopolar electrosurgery, the high-frequency current emitted by the active electrode (handle or pencil) passes through the patient’s tissue and must return to the generator via the neutral plate or dispersive electrode. If the skin-plate contact is poor or the conductive surface is insufficient, the current density at the return point increases and, with it, the risk of thermal burn. The solid gel of this plate ensures a uniform distribution of current and stable adhesion to the body contour, keeping the current density low in the contact area. As it is supplied without cable, it must be connected using the cable Ref. 30563 (GM30563), a universal bipolar cable of 5 m with forceps for disposable plates with a 22-25 mm tab and a universal mono jack connector of 6.3 mm, compatible with numerous electrosurgical generators on the market (Aesculap, Bovie, Martin, Philips, Erbe, Ritter/Mdt, Soxil and others).
3. Technical Specifications
Single-use return plate, intended for adult patients, individually packaged.
| Characteristic | Specification |
|---|---|
| Manufacturer | GIMA |
| Plate type | Disposable single-use return electrode (neutral plate) |
| Population | Adult |
| Adhesive gel | Solid gel |
| Cable | Not included; requires cable Ref. 30563 (GM30563) |
| Packaging | Individual (all plates and cables are packed separately) |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | K02010201 |
| GMDN | 58494 |
Available references
| Reference | Sales unit |
|---|---|
| GM30489 | Box of 100 units |
| GM30492 | Box of 25 units |
4. Equivalences and Cross-References
Reference 30489 (SKU Cahnos GM30489) and its variant GM30492 (box of 25 units) are the original designations from the manufacturer’s catalogue for this disposable return plate with solid gel without cable. No 1:1 equivalence table validated by the manufacturer has been found in reliable sources that cross-references this reference with codes from other brands; any substitution must be validated field by field (conductive surface, gel type and connector compatibility with the installed generator). Within the catalogue itself, this plate is part of the family of disposable return electrodes with tab connection that uses the cable Ref. 30563 (GM30563), which serves the disposable plates with tab of Refs. 30490-30495. As related references from the same family, the bipartite REM plate (Refs. 30488/30493) and the non-woven REM plates (Ref. 30495) are cited, which incorporate a contact monitoring system, as well as the plates with integrated cable Ref. 30476 and Ref. 30478 for other generator configurations.
5. Selection tips and variants of interest
As this is a plate without cable, complete the set with the connection cable Ref. 30563 (GM30563), reusable between patients. Check that your electrosurgical unit accepts disposable plates with tab (22-25 mm tab) and that the cable connector is compatible with the plug of your generator. Choose the format according to your consumption volume: the box of 100 units (GM30489) is the most cost-effective option for hospital surgical scheduling, while the box of 25 units (GM30492) suits clinics and minor surgery centres. If your generator has a socket with contact control (REM system), consider the REM variant of the same family for continuous monitoring of contact impedance. Always apply the plate to dry, intact, hair-free skin, on a well-irrigated muscular area away from bony prominences, pacemakers or metal implants; check the integrity of the individual packaging before each use. Single-use product, not reusable: request B2B conditions and supply times from our technical-commercial team. For large orders you can request a quote.






Reviews