Description
Sterile tungsten loop electrode for gynaecological surgery
The sterile tungsten loop electrode is the reference accessory for loop electrosurgical excision procedures on the cervix (LEEP/LLETZ) and cervical conization. Its precision design, with high-quality tungsten wire, allows the gynaecology specialist to make clean, controlled cuts with minimal carbonisation, obtaining intact tissue samples for histopathological examination.
Designed for hospital and gynaecology practice use, this single-use electrode eliminates reprocessing times and guarantees optimal sterility conditions in every procedure. It is part of the manufacturer’s range of electrosurgical accessories and is supplied in an individual sterile case, in a box of 10 units.
Technical explanation of the procedure
The loop electrode is mounted on a cauterisation scalpel or electrosurgical pencil and is used in the LEEP (Loop Electrosurgical Excision Procedure) or LLETZ (Large Loop Excision of the Transformation Zone) procedure, the standard technique for the diagnosis and treatment of precancerous lesions of the cervix.
Tungsten wire has a melting temperature much higher than that of stainless steel, allowing it to maintain the shape and integrity of the loop throughout the excision, even at high power settings. The result is a more stable cut, a more precise resection depth and a smaller lateral coagulation zone on the removed specimen. The tips are removable and interchangeable: they attach securely to the end of the cauterisation pencil and are compatible with most cauterisation scalpels on the market, simplifying the rotation of loop sizes according to each patient’s needs.
Technical specifications
| Parameter | Specification |
|---|---|
| Electrode type | Loop electrode |
| Loop material | Tungsten wire |
| Use | Disposable, single-use |
| Sterility | Yes, individual sterile presentation |
| Handle attachment | Removable and interchangeable tips |
| Compatibility | Cauterisation scalpels of all brands (standard connector) |
| Clinical application | LEEP/LLETZ, cervical conization, gynaecology |
| Presentation | Box of 10 units |
Available references
| Reference | Loop dimensions | Units per box |
|---|---|---|
| SP200-L31S | 10 x 10 mm | 10 |
| SP200-L45S | 15 x 12 mm | 10 |
| SP200-L37S | 20 x 12 mm | 10 |
| SP200-L35S | 20 x 15 mm | 10 |
Equivalences and cross-references
There is no official equivalence table validated by the manufacturer that cross-references this reference with codes from other brands; it is recommended to consult the technical department before using this information in a tender or surgical protocol. The following alternatives have been verified in catalogues and authorised distributors, and are comparable at category level but not interchangeable 1:1 without prior verification of connector, loop geometry and dimensions.
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| CooperSurgical | LEEP/LLETZ Electrode (tungsten wire, large radius loop) | R2015 (20 x 15 mm / 2.0 x 1.5 cm) | Comparable by category (not interchangeable 1:1) | Tungsten loop of 20×15 mm, sterile, universal shaft of 3/32″ (2.3 mm) and handle length of 12 cm; compatible with most generators. Verify connector and loop profile before replacing. |
| Medtronic | Tungsten Sterile Loop Electrode (LLETZ) | E1561 (20 x 15 mm) | Comparable by category (not interchangeable 1:1) | Tungsten loop electrode of 20×15 mm, sterile and single-use; same material and clinical purpose. Confirm shaft diameter and loop tolerance in the official datasheet. |
| Medgyn (Thomas Medical) | LEEP/LLETZ Electrode, tungsten, sterile, disposable | LE-11-205 (20 x 15 mm) | Comparable by category (not interchangeable 1:1) | Tungsten loop of 20×15 mm, sterile and disposable; verify standard 3/32″ connector and actual loop dimensions in the manufacturer’s documentation. |
In the sector there are also homologous reference families, such as the UtahLoop range from Utah Medical Products (pure tungsten loops with integrated SAFE-T-GAUGE ruler for depth control) and the loop electrodes from Medline itself (SP200 series, to which this product belongs). None of them publishes an official cross-reference with the SP200 series. There is no equivalence table validated by the manufacturer; consult the technical department at Cahnos before using any substitution in a tender or surgical protocol.
Selection tips and variants of interest
The loop size should be chosen according to the extent of the transformation zone and the anatomy of the cervix: for small lesions or partial excisions, the 10×10 mm loop (SP200-L31S) is recommended; for medium-sized resections, the 15×12 mm (SP200-L45S) or 20×12 mm (SP200-L37S) loops; and for large or single-pass conizations, the 20×15 mm (SP200-L35S), which maximises the resected tissue in a single pass.
As the tips are interchangeable, a single cauterisation pencil can be used with all four loop sizes, allowing the department to have the full SP200 range without multiplying the material. Note that each loop is single-use: calculate stock according to your centre’s monthly volume of LEEP/LLETZ procedures. For volume purchase conditions or hospital budgets, consult your technical-commercial advisor at Cahnos.