Description
1. Introduction
The reusable monopolar ball electrodes from REGER are the ideal active tip for contact coagulation in electrosurgery systems. Manufactured by REGER Medizintechnik GmbH (Germany), they are part of the manufacturer’s standard range of HF electrodes and offer consistent performance cycle after cycle thanks to their reusable and autoclavable construction at 134 °C. A cost-effective and reliable solution for operating theatres, minor surgery clinics, dermatology and ambulatory surgery centres.
2. Technical explanation
In monopolar electrosurgery, the electrosurgical generator applies high-frequency current to the tissue through the active electrode, and the circuit is closed via the neutral (dispersive) plate placed on the patient. The ball tip (sphere) concentrates energy on a rounded surface, designed for contact coagulation, desiccation and controlled fulguration: it achieves effective haemostasis of small vessels and bleeding beds with less carbonisation and less lateral thermal damage than needle or blade tips. These REGER electrodes are suitable for high-frequency (HF) and radiofrequency (RF) generators, with a maximum voltage of 4.3 kVp. The Ø 2.4 mm shaft incorporates hexagonal anti-rotation protection, which prevents the tip from rotating inside the electrode holder handle and ensures stable orientation during the surgical procedure. The product is reusable and sterilised in an autoclave at 134 °C.
3. Technical Specifications
Common features of the REGER ball electrode family with Ø 2.4 mm shaft:
| Characteristic | Value |
|---|---|
| Brand / Manufacturer | REGER Medizintechnik GmbH (Germany) |
| Model | Ball |
| Shaft diameter | Ø 2.4 mm |
| Shaft | With hexagonal anti-rotation protection |
| Maximum voltage (Umax) | 4.3 kVp |
| Compatibility | HF and RF generators |
| Type of use | Reusable |
| Sterilisation | Autoclave (134 °C) |
Manufacturer’s specifications:
| Characteristic | Value |
|---|---|
| Model | Ball |
| Maximum voltage (Umax) | 4.3 kVp |
4. Equivalences and Cross-References
The references shown below belong to the same family from manufacturer REGER (ball electrodes with Ø 2.4 mm shaft) and differ in sphere diameter, shape (straight or angled) and length. Within REGER’s standard range of HF electrodes there is also the family of ball electrodes with Ø 4 mm shaft (series 214, 240 and 271), with similar configurations for other connection needs. No 1:1 equivalence table validated by the manufacturer with other brands is available; reusable ball electrodes from other manufacturers (e.g. 2.38 mm / 3/32″ shaft) may be comparable by category, but must be validated field by field before any substitution. Please consult our technical department if you need to verify compatibility with your electrode holder handle.
5. Available references
| REGER reference | Size | Units per pack | Compatible with |
|---|---|---|---|
| 305-1 | Sizes Ø 2 mm | 5 | |
| 305-2 | Sizes Ø 4 mm | 5 | |
| 305-3 | Diameter Ø 6 mm | 5 | |
| 305-8 | Diameter Ø 2 mm · Angled | 5 | |
| 305-9 | Diameter Ø 4 mm · Angled | 5 | |
| 344-1 | Diameter 2 mm · Length 90 mm | 1 | HF and RF generators |
| 344-2 | Diameter 4 mm · Length 90 mm | 1 | HF and RF generators |
6. Selection tips and variants of interest
Choose the ball diameter according to the clinical indication: Ø 2 mm spheres provide fine, precise coagulation; Ø 4 mm spheres offer a balance between contact surface and control; and Ø 6 mm spheres cover larger areas. For lateral access or irregular contour fields, the angled versions 305-8 (Ø 2 mm) and 305-9 (Ø 4 mm) improve ergonomics without straining the surgeon’s wrist. References 344-1 and 344-2 have a length of 90 mm and are supplied in single-unit packaging. All variants share the Ø 2.4 mm shaft with hexagonal anti-rotation protection and are reusable and autoclavable at 134 °C. For institutional quotations, consumable replenishment or custom configurations, please contact our technical-commercial team at Cahnos.





Reviews