Reusable monopolar ball electrodes (ko) with Ø 2.4 mm shaft and hexagonal anti-rotation protection, from German manufacturer REGER Medizintechnik. They are autoclavable at 134 °C and suitable for high-frequency (HF) and radiofrequency (RF) generators, with a maximum voltage of 4.3 kVp. Available in ball diameters of Ø 2, 4 and 6 mm, in straight and angled versions (references 305-1 to 305-9, packs of 5 units) and in 90 mm length versions (references 344-1 and 344-2, single-unit packaging). Ideal for contact coagulation, precision haemostasis and work on soft tissue in general surgery, dermatology and minor surgery. Sold on quotation.

International shipping. Import duties and taxes are payable by the recipient.

Reference
RGR-HF-BOLA-24

Description

1. Introduction

The reusable monopolar ball electrodes from REGER are the ideal active tip for contact coagulation in electrosurgery systems. Manufactured by REGER Medizintechnik GmbH (Germany), they are part of the manufacturer’s standard range of HF electrodes and offer consistent performance cycle after cycle thanks to their reusable and autoclavable construction at 134 °C. A cost-effective and reliable solution for operating theatres, minor surgery clinics, dermatology and ambulatory surgery centres.

2. Technical explanation

In monopolar electrosurgery, the electrosurgical generator applies high-frequency current to the tissue through the active electrode, and the circuit is closed via the neutral (dispersive) plate placed on the patient. The ball tip (sphere) concentrates energy on a rounded surface, designed for contact coagulation, desiccation and controlled fulguration: it achieves effective haemostasis of small vessels and bleeding beds with less carbonisation and less lateral thermal damage than needle or blade tips. These REGER electrodes are suitable for high-frequency (HF) and radiofrequency (RF) generators, with a maximum voltage of 4.3 kVp. The Ø 2.4 mm shaft incorporates hexagonal anti-rotation protection, which prevents the tip from rotating inside the electrode holder handle and ensures stable orientation during the surgical procedure. The product is reusable and sterilised in an autoclave at 134 °C.

3. Technical Specifications

Common features of the REGER ball electrode family with Ø 2.4 mm shaft:

Characteristic Value
Brand / Manufacturer REGER Medizintechnik GmbH (Germany)
Model Ball
Shaft diameter Ø 2.4 mm
Shaft With hexagonal anti-rotation protection
Maximum voltage (Umax) 4.3 kVp
Compatibility HF and RF generators
Type of use Reusable
Sterilisation Autoclave (134 °C)

Manufacturer’s specifications:

Characteristic Value
Model Ball
Maximum voltage (Umax) 4.3 kVp

4. Equivalences and Cross-References

The references shown below belong to the same family from manufacturer REGER (ball electrodes with Ø 2.4 mm shaft) and differ in sphere diameter, shape (straight or angled) and length. Within REGER’s standard range of HF electrodes there is also the family of ball electrodes with Ø 4 mm shaft (series 214, 240 and 271), with similar configurations for other connection needs. No 1:1 equivalence table validated by the manufacturer with other brands is available; reusable ball electrodes from other manufacturers (e.g. 2.38 mm / 3/32″ shaft) may be comparable by category, but must be validated field by field before any substitution. Please consult our technical department if you need to verify compatibility with your electrode holder handle.

5. Available references

REGER reference Size Units per pack Compatible with
305-1 Sizes Ø 2 mm 5
305-2 Sizes Ø 4 mm 5
305-3 Diameter Ø 6 mm 5
305-8 Diameter Ø 2 mm · Angled 5
305-9 Diameter Ø 4 mm · Angled 5
344-1 Diameter 2 mm · Length 90 mm 1 HF and RF generators
344-2 Diameter 4 mm · Length 90 mm 1 HF and RF generators

6. Selection tips and variants of interest

Choose the ball diameter according to the clinical indication: Ø 2 mm spheres provide fine, precise coagulation; Ø 4 mm spheres offer a balance between contact surface and control; and Ø 6 mm spheres cover larger areas. For lateral access or irregular contour fields, the angled versions 305-8 (Ø 2 mm) and 305-9 (Ø 4 mm) improve ergonomics without straining the surgeon’s wrist. References 344-1 and 344-2 have a length of 90 mm and are supplied in single-unit packaging. All variants share the Ø 2.4 mm shaft with hexagonal anti-rotation protection and are reusable and autoclavable at 134 °C. For institutional quotations, consumable replenishment or custom configurations, please contact our technical-commercial team at Cahnos.

Additional information

Medida

Medidas Ø 2 mm, Medidas Ø 4 mm, Diámetro Ø 6 mm, Diámetro Ø 2 mm · Forma angulado, Diámetro Ø 4 mm · Forma angulado, Diámetro 2 mm · Longitud 90 mm, Diámetro 4 mm · Longitud 90 mm

Units per pack

5, 1

Model

Ball

Maximum voltage (Umax)

4.3 kVp

REGER reference

305-1, 305-2, 305-3, 305-8, 305-9, 344-1, 344-2

Manufacturer

REGER Medizintechnik GmbH

Product type

Reusable monopolar ball electrode

Shaft diameter

2.4 mm

Anti-rotation protection

Hexagonal anti-rotation

Maximum voltage

4.3 kVp

Compatibility

HF and RF generators

Sterilisation

Autoclave (134 °C)

References

305-1, 305-2, 305-3, 305-8, 305-9, 344-1, 344-2

Intended use

Contact coagulation, desiccation and controlled fulguration

Tipo uso

Reusable

Reviews

There are no reviews yet.

Be the first to review “Reusable monopolar ball electrodes Ø 2.4 mm – Reg. 305 and 344 | REGER | HF/RF Electrosurgery”

Your email address will not be published. Required fields are marked *