We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reusable wire loop electrode for plastic surgery REGER RGR-482-0 (6 x 2 mm · Ø 1.6 mm) – HF/RF Electrosurgery

Price on request

Active electrode with wire loop for plastic surgery from the German manufacturer REGER Medizintechnik GmbH, reference RGR-482-0 (catalogue 482-0). With a 6 x 2 mm loop and a Ø 1.6 mm shaft, it is a reusable tip that can be autoclaved at 134 °C, suitable for high-frequency (HF) and radiofrequency (RF) generators with a maximum voltage of 4.3 kVp. Ideal for precision electrosection and coagulation on soft tissue in plastic, aesthetic and minor surgery. It is supplied in a pack of 5 units and is sold on quotation: contact our technical-commercial team at Cahnos for availability and terms.

International shipping. Import duties and taxes are payable by the recipient.

Reference
RGR-482-0

Description

1. Introduction

The wire loop electrode from REGER Medizintechnik GmbH (Germany), reference 482-0 (SKU Cahnos RGR-482-0), is the reference active tip for electrosurgery in plastic and aesthetic surgery. Its wire loop design concentrates energy precisely on soft tissue, enabling fine electrosection and controlled coagulation with minimal lateral thermal damage, a decisive factor in procedures where the quality of the aesthetic result and preservation of adjacent tissues are priorities. It is a reusable electrode that can be autoclaved at 134 °C, a cost-effective and reliable solution for operating theatres, aesthetic surgery clinics and ambulatory surgery centres.

2. Technical explanation

In a monopolar electrosurgery system, the electrosurgical generator (HF or RF) applies high-frequency current to the tissue through the active electrode, which concentrates the current density at the tip to cut, coagulate or combine both effects; the circuit is closed via the neutral or dispersive plate placed on the patient. The wire loop geometry defines a reduced and homogeneous contact surface, ideal for precision work on soft tissue typical of plastic surgery: it allows fine resections, shaping and targeted haemostasis with minimal carbonisation. This electrode is suitable for high-frequency (HF) and radiofrequency (RF) generators with a maximum permissible voltage (Umax) of 4.3 kVp. As it is reusable, it is sterilised in an autoclave at 134 °C, ensuring consistent performance cycle after cycle.

3. Technical Specifications

Data verified against the official catalogue of REGER Medizintechnik GmbH (HF surgery system > HF electrodes > plastic surgery) and the Cahnos-Catalog-Loader load. The manufacturer’s specification table is preserved in full.

Manufacturer’s specifications

Characteristic Value
Measurements 6 mm x 2 mm
Diameter Ø 1.6 mm
Maximum voltage (Umax) 4.3 kVp

Product data

Field Detail
SKU Cahnos RGR-482-0
Manufacturer reference 482-0
Brand REGER
Manufacturer REGER Medizintechnik GmbH (Germany)
Product type Wire loop electrode for plastic surgery (Wire loop electrode / Spatelelektrode)
Compatibility HF and RF generators
Type of use Reusable
Sterilisation Autoclave (134 °C)
Units per pack 5
Sale Under quotation

Available references

Reference Description Measurements Units per pack Compatible with
482-0 Wire loop electrode for plastic surgery 6 mm x 2 mm 5 HF and RF generators

4. Equivalences and Cross-References

The reference RGR-482-0 is the commercial designation under which Cahnos registers the product, and 482-0 is its original code in the REGER Medizintechnik GmbH catalogue: it is the same wire loop electrode (dual coding of the same product). No 1:1 equivalence table validated by the manufacturer has been found in reliable sources that cross-references this exact configuration (loop 6 x 2 mm, shaft Ø 1.6 mm, Umax 4.3 kVp) with codes from other brands. Wire loop and spatula electrodes from other manufacturers are comparable only at category level and are not interchangeable without field-by-field verification: loop geometry and dimensions, shaft diameter, connector type, fixation system and electrical compatibility of the generator. Consult our technical-commercial department before using any equivalence in tenders or substitutions.

5. Selection tips and variants of interest

Always verify that your electrode handle accepts the shaft diameter of Ø 1.6 mm and the fixation system of this electrode before purchase. This model is supplied in a pack of 5 units and is reusable: sterilise it in an autoclave at 134 °C after each use and periodically check the condition of the wire, as deformation or wear of the loop compromises the quality of cutting and coagulation. For other needs within precision electrosurgery, REGER offers a wide range of reusable, autoclavable active electrodes available at Cahnos, such as the blade, spatula and lancet families (e.g. reference 300-0) and ball electrodes. For institutional volumes, hospital supply agreements or annual consumption terms, contact the technical-commercial team at Cahnos. This product is sold on quotation.

Additional information

Measurements

6 mm x 2 mm

Diameter

Ø 1.6 mm

REGER reference

482-0

Manufacturer

REGER Medizintechnik GmbH

Manufacturer reference

482-0

Product type

Wire loop electrode for plastic surgery

Maximum voltage umax

4.3 kVp

Compatibility

HF and RF generators

Sterilisation

Autoclave (134 °C)

Units per pack

5

Indications

Plastic and aesthetic surgery

Tipo uso

Reusable

Reviews

There are no reviews yet.

Be the first to review “Reusable wire loop electrode for plastic surgery REGER RGR-482-0 (6 x 2 mm · Ø 1.6 mm) – HF/RF Electrosurgery”

Your email address will not be published. Required fields are marked *