Description
The disposable electrosurgery electrode Ref. F4640 incorporates a trapezoidal loop of 30 × 5 mm made of 0.2 mm tungsten wire, mounted on a 2.38 mm stainless steel shaft. Its wide-sail, shallow-depth design allows broad, regular excisions with an excellent balance between clean cutting and controlled coagulation. Each unit is supplied sterile, individually packaged, in a box of 24 units designed for stock rotation in gynaecology, colposcopy and operating theatre settings.
Technical explanation of the product and procedure
The loop electrode operates in monopolar electrosurgery: the radiofrequency current from the electrosurgical generator is concentrated in the tungsten wire of the loop and allows cutting and coagulating tissue simultaneously. Tungsten provides rigidity and dimensional stability when hot, preventing the loop from deforming during excision and reducing thermal damage to the specimen margins. It is the reference electrode type in loop electrosurgical excision procedures (LEEP/LLETZ) in colposcopy, for excision of the cervical transformation zone and obtaining a histological sample with assessable margins.
The connector’s hexagonal locking system prevents the electrode from rotating during use, and the high-impact plastic (HIPS) anti-shock protector ensures professional safety. The 2.38 mm (3/32″) shaft is the universal standard for most disposable and reusable electrosurgical pencils.
Technical specifications
| Tip shape | Trapezoidal loop (trapezoidal sail), 30 × 5 mm |
| Loop material | Tungsten, Ø 0.2 mm wire |
| Shaft material | AISI stainless steel |
| Shaft diameter | 2.38 mm (3/32″) |
| Total length | 135 mm ± 3% |
| Insulation / protection | High-impact plastic (HIPS) anti-shock protector, latex-free |
| Compatibility | Electrosurgical pencils with universal 2.38 mm (3/32″) connection |
| Type of use | Disposable, single-use |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 24 units, individual sterile packaging |
| Regulatory classification | Medical device class IIb, in accordance with Directive 93/42/EEC and amendments |
| Expiry | 4 years from production date if stored correctly |
| Storage | Temperature 0 to +50 °C; relative humidity 20–80% |
| Product reference | F4640 |
Equivalences and cross-references
No other manufacturer offering the exact 30 × 5 mm format in a trapezoidal tungsten loop with a 2.38 mm shaft has been identified in official sources; therefore, there is no manufacturer-validated equivalence table; consult the technical department before using in a tender.
As homologous families comparable at category level (not 1:1 interchangeable), verified against their manufacturers’ official catalogues, the following lines of disposable tungsten loops for LEEP/LLETZ are identified:
- Bovie (Aspen Surgical) — LLETZ Loop Electrodes: refs. ES44 (15 × 5 mm), ES47 (25 × 10 mm) and ES49 (20 × 10 mm). Tungsten loop, 3/32″ (2.3 mm) shaft, sterile; they differ in width/depth and in packaging (5 units).
- Megadyne (Ethicon) — LLETZ Loop Electrodes: refs. 0420 (10 × 5 mm, purple), 0410 (10 × 7 mm, orange) and 0440 (20 × 10 mm, red). Fine tungsten loop with Y construction and distal insulation; box of 12 units.
- CooperSurgical — LEEP Large-Radius Loop Electrodes: refs. R2510 (25 × 10 mm) and R2008 (20 × 8 mm), 12 cm shaft, pack of 5; large-radius geometry for broad excisions.
- MedGyn — Disposable Electrodes: refs. 028069 (10 × 5 mm) and 028070 (10 × 7 mm), tungsten wire on a 2.3 mm stainless steel shaft, pack of 5.
- DTR Medical — Colposcopy LLETZ Loop Electrodes: refs. LEC1131005-LP (10 × 5 mm) and LEC1132010-RE (20 × 10 mm), 130 mm shaft, pack of 10, with colour coding.
In all cases, the compatibility of the connector with the electrosurgical pencil in use and the suitability of the geometry for the clinical indication must be checked in the corresponding manufacturer’s technical data sheet.
Selection tips and variants of interest
- Geometry: the 30 × 5 mm format (width 30 mm, depth 5 mm) is designed for broad, shallow excisions of the cervical transformation zone.
- Size selection: if the lesion is smaller or has an irregular outline, within the same family the formats F4641 (23 × 13 mm, reverse curved) and F4642 (17 × 12 mm, triangular) are available, sharing the 2.38 mm shaft platform and tungsten loop.
- Compatibility: verify that the electrosurgical pencil in your inventory accepts the universal 2.38 mm (3/32″) connector.
- Consumption and storage: the box of 24 units facilitates stock management; store between 0 and +50 °C with relative humidity of 20–80% and respect the 4-year expiry date.
- Clinical validation: before replacing with another brand, confirm in the alternative product’s IFU the compatibility, sterility and regulatory classification (MDR/93-42-EEC).