Description
1. Introduction
The monopolar electrodes REGER for dentistry and aesthetics are the solution from the German manufacturer REGER Medizintechnik GmbH for electrosurgery interventions on soft tissues in the dental and cosmetic field. Their Ø 3 mm shaft makes them compatible with the handles and systems of the chirurgery HF series from REGER, as well as with high-frequency (HF) and radiofrequency (RF) generators indicated by the manufacturer. A versatile and economical series, designed for reusable professional use in practice and clinic.
2. Technical Explanation
In monopolar electrosurgery, the high-frequency current is applied in a concentrated manner through the active electrode, allowing precise cuts and controlled coagulation of soft tissue with minimal thermal damage to the surrounding area. These electrodes come in two main geometries: the wire loop, ideal for excision, shaping and tissue reduction, and the needle electrode, designed for fine incisions and maximum precision work. Being reusable and autoclavable at 134 °C, they offer a long service life with the safety of hospital sterilisation, reducing the cost per procedure compared to single-use consumables.
3. Technical specifications and available references
| Characteristic | Value |
|---|---|
| Electrode type | Monopolar (HF and RF) |
| Shaft diameter | Ø 3 mm |
| Maximum voltage (Umax) | 4.3 kVp |
| Reusable | Yes |
| Sterilisation | Autoclavable (134 °C) |
| Compatibility | HF and RF generators |
| Units per pack | 5 |
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Maximum voltage (Umax) | 4.3 kVp |
Available references
| REGER reference | Model | Measurements | Units per pack | Compatible with |
|---|---|---|---|---|
| 404-0 | Wire loop | Ø 3 mm | 5 | HF and RF generators |
| 405-0 | Wire loop | Ø 5 mm | 5 | HF and RF generators |
| 406-0 | Wire loop | Ø 8 mm | 5 | HF and RF generators |
| 401-0 | Needle electrode | 0.2 mm | 5 | HF and RF generators |
4. Equivalences and Cross-References
References 404-0, 405-0, 406-0 and 401-0 form the series of dental and aesthetic electrodes REGER with Ø 3 mm shaft; they complement each other by geometry and size, without being interchangeable from a clinical point of view. The manufacturer REGER also offers an analogous family with Ø 1.6 mm shaft (references 402-0, 416-0, 417-0, 417-1, 418-0, 418-1 and 419-0) for those who need smaller diameter shafts in the same type of applications. No direct 1:1 equivalence tables with electrodes from other manufacturers have been found in reliable sources: the clamping systems and handle connectors of brands such as Erbe, KLS Martin or BOWA are specific to each manufacturer, so any substitution must be verified with the technical department before use in tendering.
5. Selection tips and variants of interest
- Ref. 404-0 (loop Ø 3 mm): indicated for excision and precision work in small areas.
- Ref. 405-0 (loop Ø 5 mm): the general-purpose size for cutting and shaping tissue in dentistry.
- Ref. 406-0 (loop Ø 8 mm): recommended for larger surfaces and rapid tissue reduction.
- Ref. 401-0 (needle 0.2 mm): for fine incisions, spot coagulation points and delicate aesthetic work.
For correct operation, always use the electrodes with the electrode holder handle suitable for the Ø 3 mm shaft diameter and respect the autoclave sterilisation cycles at 134 °C. Consult our technical-commercial team for institutional configurations, supply of complete series or customised quotations.