Description
1. Introduction
The reusable conization electrodes of Ø 2.4 mm from REGER Medizintechnik are active monopolar electrodes designed for electrosurgical excision of the cervix (cervical conization, LEEP/LLETZ techniques) and for soft tissue surgery with high-frequency current. Their Teflon-insulated tungsten needle ensures a clean and stable cut, with minimal carbonisation and excellent preservation of the specimen for histopathological examination. Being reusable and autoclavable at 134 °C, they help optimise the cost per procedure in gynaecology clinics, colposcopy and minor surgery theatres. They are sold on quotation, without public price display.
2. Technical explanation
In monopolar electrosurgery, the active electrode concentrates the current emitted by the high-frequency electrosurgical generator at the point of contact with the tissue, which returns through the neutral plate. The geometry of the conization loop delimits the resection area and allows a cone of tissue to be extracted with defined margins, controlling both cutting and haemostasis. The tungsten wire withstands temperatures much higher than steel without deforming, maintaining the shape of the loop throughout the procedure and reducing lateral thermal damage.
The Ø 2.4 mm shaft incorporates anti-twist hexagonal protection, which secures the electrode to the electrode holder handle and prevents accidental rotation during use. The needle is Teflon-insulated, which protects adjacent tissues and concentrates the energy at the active tip. They are suitable for high-frequency (HF) and radiofrequency (RF) generators, with a maximum permissible voltage of 500 Vp.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Model | Conization electrode (Konisationselektrode) |
| Shaft diameter | 2.4 mm |
| Length | 105 mm |
| Tip length | 25 mm |
| Tip material | Tungsten needle insulated in Teflon |
| Use | Reusable |
| Sterilisation | Autoclavable at 134 °C |
| Protection | Anti-twist hexagon (hexagon anti-twist protection) |
| Compatibility | HF and RF generators |
| Maximum voltage (Umax) | 500 Vp |
| Units per pack | 1 |
Available references
| REGER reference | Loop width | Units per pack | Compatible with |
|---|---|---|---|
| 364-0 | 10 mm | 1 | HF and RF generators |
| 362-0 | 15 mm | 1 | HF and RF generators |
| 363-0 | 20 mm | 1 | HF and RF generators |
Data verified according to the catalogue of REGER Medizintechnik (reger-medical.de) and the Cahnos-Catalog-Loader.
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that cross-references the 364-0, 362-0 and 363-0 references with codes from other brands. These references are offered as a functional comparison of verified category against official sources, never as direct 1:1 interchangeable items. In the sector there are homologous families of reusable conization electrodes with Ø 2.4 mm shaft and tungsten loop from manufacturers such as Erbe, KLS Martin, Bovie (Aspen Surgical) and Söring, in addition to the sterile disposable LEEP/LLETZ ranges from CooperSurgical and Megadyne. Before using any substitution in tenders or surgical protocols, consult the technical department of Cahnos and compare shaft diameter, connector, fixation system and dimensions with the manufacturer’s data sheet.
5. Selection tips and variants of interest
Select the loop width according to the extent of the lesion and the desired cone: the 364-0 (10 mm) is the option for small cones or partial excisions; the 362-0 (15 mm) covers most medium-sized conizations; and the 363-0 (20 mm) is reserved for large cones in a single pass. Before purchasing the handle, verify that it accepts a Ø 2.4 mm shaft and the anti-twist hexagonal system.
Remember that they are reusable: sterilise them in an autoclave at 134 °C after each use and periodically check the condition of the tungsten needle, as deformation or wear of the Teflon insulation compromises the quality of the excision. If you have a handle with a Ø 4 mm connector, the same manufacturer offers the Ø 4 mm shaft conization family (references 264-0, 262-0 and 263-0). For hospital purchases, tenders or volume conditions, consult your technical-commercial advisor at Cahnos.