We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

US bipolar cable for MB 240-380 electrosurgical unit – 3 m, American connector (Ref. 30618)

85,50 €

High-flexibility silicone bipolar cable 3 m long with US connector (American 2-pin) for bipolar forceps (ref. 30618). Compatible with the MB 240 and MB 380 electrosurgical units and with generators from the leading brands (Valleylab, Conmed, Codman, Olympus). Autoclavable at 134 °C for at least 20 cycles; ethylene oxide (EtO) sterilisation is recommended to maximise its service life. Reusable Class I medical device (sales unit: 1 unit). For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM30618

Description

1. Commercial Introduction

The US bipolar cable for MB 240-380 (ref. 30618) is the connection accessory that your electrosurgery department needs to ensure reliable, precise and safe bipolar coagulation in the operating theatre. Made of high-flexibility silicone, it offers excellent handling during the procedure and great resistance to continued use, making it the ideal complement for the bipolar forceps in the range and from the leading brands on the market.

For large orders you can request a quote: ask our technical-commercial team for a quotation to confirm availability and supply conditions.

2. Technical Explanation

In bipolar electrosurgery, the current flows only between the two branches of the forceps, with no need for a patient plate, which reduces the risk of collateral damage to adjacent tissues. This cable transmits energy from the electrosurgical unit to the bipolar forceps thanks to its US connector (American 2-pin standard), designed for equipment with an American-type forceps input.

The cable is made of high-flexibility silicone and has a length of 3 metres, enough for comfortable mobility of the surgeon without strain on the connections. It is autoclavable at 134 °C for a minimum of 20 cycles, and ethylene oxide (EtO) sterilisation is recommended to maximise its service life. The box and manual are multilingual (15 European languages, Arabic and Japanese).

3. Technical Specifications

Connector US (American 2-pin standard)
Cable length 3 m (10″)
Material High-flexibility silicone
Sterilisation Autoclavable at 134 °C (minimum 20 times); EtO recommended for maximum service life
Brand/model compatibility MB 240, MB 380; VALLEYLAB, CONMED, CODMAN, OLYMPUS
Additional compatibility (with ref. 30642) MB 122, MB 160, MB 200, MB 202

Product data

Manufacturer GIMA
Manufacturer reference 30618
Sales unit 1 pc
Device type Medical device
Device class I
CND L1899
EAN 8964000208748

4. Equivalences and Cross-References

Within the same family, the version with European connector (EU) for these same MB 240 and MB 380 electrosurgical units corresponds to reference 30632. For other equipment fleets, it offers US bipolar cables compatible with the MB 120F/200D/F/250/300D/400/400D ranges (ref. 30637) and MB 80D/120D/160D (ref. 30644), as well as the equivalent EU versions (refs. 30640 and 30617) and the 2-pin EU cable for MB 122, MB 132, MB 160, MB 200 and MB 202 (ref. 30643). The set with the Ref. 30642 adapter extends the compatibility of this cable to the MB 122, MB 160, MB 200 and MB 202 models.

This cable is the recommended accessory for insulated bipolar forceps with US connector, such as the Adson forceps of 12.1 cm (ref. 30620), completing the bipolar coagulation system.

5. Selection tips and variants of interest

To select the right bipolar cable, first check the connector type of your electrosurgical unit: choose the version with US connector (ref. 30618) for equipment with an American forceps input and the version with EU connector (ref. 30632) for European standards. Also confirm the model of your generator: this cable directly covers the MB 240 and MB 380 and the Valleylab, Conmed, Codman and Olympus equipment, and with the 30642 adapter it extends its compatibility to the MB 122, MB 160, MB 200 and MB 202.

Complete your system with insulated bipolar forceps and other accessories from the electrosurgery range. Our technical-commercial team will advise you to confirm the most suitable reference for your equipment fleet.

Additional information

Manufacturer reference

30618

Device type

Medical device (medical device)

CND code

L1899

EAN

8964000208748

Connector

US (2-pin, American)

Material

High-flexibility silicone

Sterilisation

Autoclavable at 134 °C (min. 20 cycles); EtO recommended

Compatibility

GIMA MB 240, MB 380; VALLEYLAB, CONMED, CODMAN, OLYMPUS

Additional compatibility

With ref. 30642: GIMA MB 122, MB 160, MB 200, MB 202

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

I

Longitud

300 cm

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “US bipolar cable for MB 240-380 electrosurgical unit – 3 m, American connector (Ref. 30618)”

Your email address will not be published. Required fields are marked *