Reusable FIAB adapter for disposable neutral plate, from Valleylab-type connection to 4 mm plug — Ref. F4828

Price on request

Reusable adapter FIAB Ref. F4828 for disposable neutral electrodes: converts the Valleylab-type connection of the plate into a standard 4 mm plug, expanding the compatibility of your electrosurgical unit with single-use return plates. Robust, reusable and easy-to-clean connection accessory, suitable for operating theatre, minor surgery and sterilisation centre. It also has the 6.3 mm plug variant (Ref. F4829).

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-F4828
Brand
FIAB

Description

1. Product Presentation

The reusable adapter FIAB Ref. F4828 is the connection accessory that allows the use of disposable neutral plates with Valleylab-type connection in electrosurgery equipment whose return socket is a standard 4 mm plug. It is a small piece but with a decisive function in the safety of the monopolar circuit: it guarantees a firm and stable connection interface between the return electrode (plate) and the electrosurgical generator, avoiding false contacts and impedance drops during the procedure.

It is a reusable component, which makes it an economical and sustainable solution compared to the integrated wiring of disposable plates with cable: with a single adapter, plates from different manufacturers can be connected, as long as they share the same connection standard.

2. Technical explanation of the accessory

In any monopolar electrosurgical unit procedure, the high-frequency current exits through the active electrode (handle or pencil), passes through the patient’s tissue and must return to the generator through the neutral electrode or return plate. For this return to be safe, the connection between the plate and the equipment must be electrically correct and mechanically stable: any slack or connector incompatibility can increase the circuit impedance and, with it, the risk of local heating or burns to the patient.

This FIAB adapter precisely resolves the interface between two standards: on the one hand, the female socket type Valleylab, present on widely used disposable neutral plates with cable; on the other, the 4 mm plug, the usual return socket on numerous electrosurgical generators. As it is a reusable element, it must be inspected before each use to verify the integrity of the connector and the cleanliness of the contacts, and reprocessed according to the manufacturer’s instructions.

3. Technical Specifications

Characteristic Value
Reference FIAB F4828
Product type Reusable adapter for disposable neutral plate (electrode)
Inlet connection Valleylab type (female socket for disposable plate)
Outlet connection 4 mm plug
Use Reusable
Packaging Single unit
Units per box (web) 1

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer that cross-references the F4828 reference with codes from other brands; the Valleylab-type connection standard is widespread in the market for disposable return electrodes (plate families from Medtronic-Covidien/Valleylab, Aesculap, BOWA or Erbe, among others), so this adapter can help expand the compatibility of plates from different origins as long as the connector physically matches. For any replacement or mixed electrosurgery fleet, consult our technical-commercial department to validate the compatibility of the connector with your generator and with the plate in use.

5. Selection tips and variants of interest

Always check the type of return socket on your electrosurgical unit before choosing the adapter: if your generator uses a 4 mm plug, this F4828 reference is the one indicated for disposable plates with Valleylab-type connection. If your equipment uses a 6.3 mm bipolar plug, the equivalent option in this same family is Ref. F4829, and for cableless plates with tab (TAB) connection, the reusable adapter cables F7902 (universal 6.3 mm), F7903 (Valleylab type) or F7904 (for ERBE) can be used. Complete your system with the disposable return plates FIAB from the F7805/F7820 series and always check the condition of the adapter before each procedure.

Additional information

Brand

FIAB

Packaging

Single unit

Manufacturer reference

F4828

Product type

Reusable adapter for disposable neutral plate

Inlet connection

Valleylab type

Outlet connection

4 mm plug

Presentation

Single unit

Units per box

1

Manufacturer

FIAB SpA (Vicchio, Florence, Italy)

Tipo uso

Reusable