1. Product Presentation
We present the original FIAB connection cable (Ref. F7922/24) for reusable neutral plates, an essential accessory for completing the monopolar circuit of your electrosurgery with maximum reliability. With a length of 500 cm and a double 4 mm plug, this cable connects the return plate directly to the electrosurgical unit and allows the neutral electrode to be reused in multiple procedures after cleaning.
It is the usual choice in operating theatres, minor surgery consulting rooms, dermatology, dentistry and veterinary clinics that wish to reduce healthcare waste and the recurring cost of single-use electrodes, while maintaining a safe and stable return contact.
2. Technical explanation
In monopolar electrosurgery, the high-frequency current exits through the active electrode (pencil), passes through the patient’s tissue and must return to the generator via a low current-density path: the neutral plate or return electrode. The quality of that path depends both on the plate and on the cable that connects it to the electrosurgical unit.
This FIAB F7922/24 cable guarantees that connection with a double 4 mm plug configuration, suitable for reusable neutral plates equipped with a 4 mm socket. The plate-cable assembly ensures a low and stable contact impedance, an essential condition to avoid current density concentrations that could lead to burns on the patient.
It is a reusable accessory: it must be cleaned after each use, visually inspected (without cuts, cracks or deterioration of the insulation) and its continuity periodically checked before each procedure.
3. Technical Specifications
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F7922/24 |
| Packaging | Single unit |
| Units per box (web) | 1 |
Product features
| Characteristic | Value |
|---|---|
| Brand / Manufacturer | FIAB / FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Connection cable for reusable neutral plate (return electrode) |
| Length | 500 cm |
| Connector | Double 4 mm plug |
| Type of use | Reusable |
| Compatibility | Reusable neutral plates FIAB with 4 mm socket: F7930 (with REM system) and F7915 (without REM) |
Available references
| Reference | Description | Length |
|---|---|---|
| F7922/24 | Cable with double 4 mm plug | 500 cm |
4. Equivalences and Cross-References
This cable belongs to the FIAB range of connection cables for reusable neutral plates. Depending on the generator connector installed in your centre, it can be completed with these references from the same commercial family:
| Reference | Description |
|---|---|
| F7922 | Universal cable, 6.3 mm mono jack connector, with junction box, 500 cm |
| F7922/WB | Cable with 6.3 mm mono jack connector, without junction box, 500 cm |
| F7922/4 | Cable with 4 mm plug, 500 cm |
| F7922/24 | Cable with double 4 mm plug, 500 cm |
| F7923 | Valleylab type cable (ESU with REM), 500 cm |
| F7923/F | Valleylab type cable (ESU without REM), 500 cm |
| F7924 | Special 6.3 mm mono jack cable for ERBE (ACC, ICC, VIO, T), 500 cm |
This cable is intended for use with the reusable silicone neutral plates of the same range: the F7930 plate (200 x 150 mm, 250 cm², with REM system and 4 mm socket) and the F7915 plate (without REM system, same 4 mm socket). There is no official equivalence table validated by the manufacturer with cables from other brands; before any replacement, confirm with the technical department the compatibility of the connector with your generator.
5. Selection tips and variants of interest
Check the connector of your equipment: the F7922/24 reference uses a double 4 mm plug. If your generator requires a single 4 mm plug, consider the F7922/4 reference; for a 6.3 mm mono jack connector, the references F7922 (with junction box) or F7922/WB (without junction box).
Other configurations: if your equipment uses a Valleylab-type connector, consider references F7923 (with REM) or F7923/F (without REM); for ERBE generators of the ACC, ICC, VIO and T series, reference F7924.
Compatible plate: use it with FIAB reusable plates with 4 mm socket (F7930 with REM or F7915 without REM) to ensure a stable return contact.
Maintenance: clean the cable after each use with the products indicated by the manufacturer, dry it completely and avoid sharp bends; check the insulation and continuity before each procedure and replace it at any sign of degradation.
Institutional purchases: for operating theatre supplies or volume orders with special B2B terms, contact our technical-commercial department.





Reviews