Cable for reusable electrosurgical plates (Ref. 30560) – Connection for steel-rubber plates 30555, 30556 and 30566

50,35 €

Reusable connection cable from the manufacturer (Ref. 30560 / SKU GM30560), designed to connect the reusable steel-rubber electrosurgical plates of references 30555, 30556 and 30566 to the electrosurgical unit, safely closing the monopolar return circuit. An essential replacement accessory to keep your reusable neutral plates operational in the operating theatre, minor ambulatory surgery and veterinary clinic. Class II B medical device, supplied as a unit; contact our technical-commercial team for B2B terms and volume agreements. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM30560

Description

Cable for reusable electrosurgical plates (Ref. 30560)

1. Commercial Introduction

The connection cable Ref. 30560 is the reusable accessory that services the steel-rubber electrosurgical plates of references 30555, 30556 and 30566, ensuring the safe return of the high-frequency current in any procedure using a monopolar electrosurgical unit. An Italian reference brand in medical equipment, this cable allows you to keep using your centre’s reusable neutral plates, reducing the cost per procedure and healthcare waste compared with disposable consumables. For large orders you can request a quote: contact our technical-commercial team for B2B terms, supply lead times and volume agreements.

2. Technical explanation

In monopolar electrosurgery, the high-frequency current emitted by the active electrode (handle or pencil) must return to the generator through the neutral plate or dispersive electrode placed on the patient. The plate cable transmits this return current from the plate to the electrosurgical unit, ensuring a firm and stable electrical connection that keeps the current density low in the skin-plate contact area, an essential requirement to avoid thermal burns and allow the correct operation of return monitoring systems. As it is a reusable accessory for rubber, steel-rubber and reusable metal plates, it must be checked periodically to detect cuts, bends, insulation wear or loss of conductivity, replacing it before each procedure if any deterioration is found.

3. Technical Specifications

Manufacturer GIMA
Manufacturer reference 30560
SKU Cahnos GM30560
Product type Connection cable for reusable electrosurgical plates (steel-rubber and metal)
Compatibility Plates Ref. 30555, 30556 and 30566
Use Reusable
Sales unit 1 pc
Device type Medical device (Medical device)
Device class II B
EAN 8033638324721

Available references

Reference Description Sales unit
30560 Cable for reusable plates (30555, 30556, 30566) 1 pc
30555 Reusable steel-rubber plate (uses cable 30560) 1 pc
30556 Reusable steel-rubber plate (uses cable 30560) 1 pc
30566 Reusable metal neutral plate without cable (requires cable 30560) 1 pc

4. Equivalences and Cross-References

Reference 30560 (SKU Cahnos GM30560) is the manufacturer’s original catalogue designation for this reusable plate cable. No official equivalence table validated by the manufacturer and cross-referencing this reference with 1:1 cables from other brands has been found in reliable sources; any replacement with cables from other manufacturers must be validated field by field (connector type, length and compatibility with the plate and the generator) with the technical department of Cahnos. Within the electrosurgery range itself, this cable is complemented by the flexible steel-rubber plate (Ref. 30555/30556), the reusable metal plate (Ref. 30566) and other connection cables such as Ref. 30563 (for disposable plates with tab) and Ref. 30575 (for REM plates). As homologous families in the sector that must be evaluated with the technical data sheet in hand before any replacement, the cables and neutral plates of Aesculap (B. Braun), Medtronic-Covidien (Valleylab), Erbe, BOWA and Leonhard Lang (Skintact) are cited.

5. Selection tips and variants of interest

Always check that the connector of this cable is compatible with the plate socket of your electrosurgical unit and with the reusable plate you are going to use (Ref. 30555, 30556 or 30566). If you work with disposable plates with tab, the appropriate cable is Ref. 30563 (universal mono jack connector, 6.3 mm, 5 m); if you use bipartite rubber REM plates, Ref. 30574 requires the Ref. 30575 cable. To complete the equipment in your operating theatre, Cahnos offers monopolar handles, electrodes, cables, neutral plates and pedals from the range; contact our technical-commercial team to configure your electrosurgery system and request B2B terms.

Additional information

Manufacturer reference

30560

Product type

Connection cable for reusable electrosurgical plates

Compatibility

Plates ref. 30555, 30556 and 30566

EAN

8033638324721

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Tipo uso

Reusable

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateMultilingüe PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF