Description
1. Product Presentation
Ensure the continuity of care for your cardiology department with the ECG thermal paper pack reference 32983 (SKU GM32983). Each pack contains 300 sheets of 80×70 mm with a pre-printed orange grid and marker, ensuring clear, stable and perfectly measurable electrocardiograms in every examination. It is indicated for the electrocardiographs Esaote Biomedica P 8000 Base and Schiller AT 101, and is supplied in a box of 20 packs to ensure planned and cost-effective replenishment in clinics, emergency departments and health centres.
2. Technical Explanation
This consumable uses direct thermal printing technology: the thermal head of the electrocardiograph transfers heat to the heat-sensitive layer of the paper and generates the trace instantly, without the need for ink, toner or ribbon, which reduces equipment maintenance and maintains consistent print quality throughout the pack.
The pre-printed orange grid acts as a millimetric measurement reference: it allows the amplitude of the waves to be assessed in millivolts (mV), the duration of segments and intervals (PR, QT, RR) and the recording speeds in mm/s, facilitating the clinical interpretation of the electrocardiogram and its subsequent filing in the clinical record. The built-in marker allows the equipment to synchronise events and time reference marks on the trace.
Its PHENOL FREE formulation, completely free of phenols, guarantees maximum safety for the user and the patient, eliminating exposure to phenolic compounds and reducing the risk of premature fogging of the recording. As a medical recording paper with a measuring function, it belongs to the range of class I medical devices.
3. Technical Specifications
Technical specifications
| Characteristic | Value |
|---|---|
| Type | Pack |
| Width | 80 mm |
| Length | 70 mm |
| Sheets | 300 |
| Marker | Yes |
| Grid | Orange |
| Composition | Phenol-free thermal paper (PHENOL FREE) |
| Printing system | Direct thermal by printhead (no ink or toner) |
Compatibility (according to catalogue)
| ECG manufacturer | Compatible model |
|---|---|
| ESAOTE BIOMEDICA | P 8000 Base |
| SCHILLER | AT 101 |
Product data
| Value | Value |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 32983 |
| Sales unit | Box of 20 packs |
| Device type | Medical device (Medical device) |
| Device class | I M |
| CND | Z1302 |
| EAN | 8023279329834 |
Available references
| Reference | SKU Cahnos |
|---|---|
| 32983 | GM32983 |
4. Equivalences and Cross-References
The declared compatibility for this 80×70 mm pack is limited to the models Esaote Biomedica P 8000 Base and Schiller AT 101. There is no official equivalence table validated by the manufacturer that cross-references this exact reference with consumables from other brands, so no 1:1 equivalents are indicated. For comparative purposes by category (same 80×70 mm format, ECG thermal paper), the following references are found in reliable sources:
| Manufacturer / Brand | Format | Code / SKU | Level |
|---|---|---|---|
| LUMEDlink (distribution line) | 80×70 mm, 300 sheets, marker: yes, orange grid | CFSC012 (code 106008) | Comparable by category (not 1:1) |
| Cahnos – Block for Esaote P-8000 Base / Schiller AT-101 | 80×70 mm, 315 sheets, red grid, Z-fold | 0992026-EB | Comparable by category (not 1:1, different grid colour and number of sheets) |
| EasyTrace® (Deas S.r.l.) | 80×70 mm, 300 folded sheets | OB8070P | Comparable by category (not 1:1) |
Before any substitution in tenders or purchases, verify the width, the number of sheets, the grid colour and the presence of a marker supported by your electrocardiograph, and confirm the exact compatibility with the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
Before replenishing, check three data points on your electrocardiograph: the admissible sheet width (80 mm), the loading format (sheet pack versus roll or Z-fold) and the grid colour required to interpret the traces (orange in this reference). Also confirm the number of sheets (300) and consult the equipment manual to validate the models Esaote Biomedica P 8000 Base and Schiller AT 101 indicated by the manufacturer.
Do not confuse this consumable with other formats in the family of different width, number of sheets or presentation, which correspond to different equipment and are not interchangeable without verification:
| Reference Cahnos | Format | Declared equipment (according to) |
|---|---|---|
| GM33012 (Ref. 33012) | Pack 80×90 mm × 280 sheets · orange grid | Marquette · Hellige · GE MAC 400 / MAC 600 |
| GM33016 (Ref. 33016) | Z-Fold pack 80×70 mm × 200 sheets | Z-Fold compatible formats |
| GM32969 (Ref. 32969) | Roll 80 mm × 20 m · orange grid | Biocare, Biolight, Bioset-Horman, Comen, Contec |
| GM32958 (Ref. 32958) | Pack 112×100 mm × 300 sheets · orange grid | Cardioline Delta 3 Plus |
For services with intensive consumption, purchasing by box of 20 packs ensures continuity of supply and an optimised cost per recording. Store the paper in a cool, dry place away from direct sunlight (5–40 °C) to preserve the sensitivity of the thermal layer and prevent the trace from fogging during its time in the clinical archive. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility and a formalised quote under B2B conditions.




Reviews
There are no reviews yet.