Description
1. SensiCare® PI surgical gloves from Medline
The SensiCare® PI surgical gloves from Medline are sterile polyisoprene gloves, latex-free and powder-free, providing the user with the performance of natural latex without the risk of an allergic reaction. Thanks to their exclusive synthetic polyisoprene formulation with a chemical structure practically identical to that of latex, they offer the same degree of comfort, elasticity and flexible movement, with an excellent anatomical fit and a very natural tactile sensation. They are the ideal choice for operating theatres, hospital purchasing centres and all types of aseptic environments where a reliable sterile barrier and high comfort are required during long-duration procedures.
2. Technical Explanation
Polyisoprene is a synthetic elastomer (cis-polyisoprene) whose mechanical properties replicate those of natural rubber: high elasticity, excellent recovery and tensile strength, but free from the allergenic latex proteins responsible for type I sensitisation. These sterile surgical gloves also eliminate powder, which helps increase staff safety and reduce the transmission of germs in the surgical field. Their inner polymer coating (E-Z Glide technology) allows easy donning even with damp hands, while the rolled and tight cuff adheres to the surgical gown and prevents the glove from slipping during use. The anatomical mould design reduces hand fatigue during prolonged procedures and the smooth cream-coloured finish offers a comfortable grip. It is tested for permeability to chemotherapy agents and meets the barrier and safety requirements of a quality surgical glove.
3. Technical Specifications
Available references
| Reference | Size | Units per box | Units per pack |
|---|---|---|---|
| MSG9055 | 5.5 | 200 | 50 |
| MSG9060 | 6 | 200 | 50 |
| MSG9065 | 6.5 | 200 | 50 |
| MSG9070 | 7 | 200 | 50 |
| MSG9075 | 7.5 | 200 | 50 |
| MSG9080 | 8 | 200 | 50 |
| MSG9085 | 8.5 | 200 | 50 |
| MSG9090 | 9 | 200 | 50 |
Technical data
| Manufacturer | Medline |
|---|---|
| Family code | P-DY94C |
| Material | Synthetic polyisoprene (Isolex formulation) |
| Allergenic potential | Latex-free |
| Finish | Powder-free, cream colour, smooth finish |
| Inner coating | Yes · Polymer coating (E-Z Glide) |
| Anatomical fit | Yes |
| Cuff design | Beaded and fitted, anti-slip |
| Thickness at the finger | 0.23 mm |
| Thickness at the palm | 0.20 mm |
| Thickness at the cuff | 0.17 mm |
| Extra length | 295 mm |
| Viral penetration | Tested to EN 374-5 |
| Glove standards | Tested in accordance with EN 455 |
| Certified as PPE | Yes |
| Sterility | Sterile, single-use |
| Presentation | Box of 200 units · Pack of 50 units |
| Available sizes | 5.5, 6, 6.5, 7, 7.5, 8, 8.5 and 9 |
4. Equivalences and Cross-References
The following references belong to other manufacturers and are classified as comparable by category (sterile surgical glove of synthetic polyisoprene, powder-free and latex-free), not interchangeable 1:1 without prior technical validation, since each manufacturer applies its own formulation, thickness and coating. Always check thicknesses, coating and standards against the technical data sheet of each brand.
| Manufacturer / Brand | Family / Model | Code / SKU (by size) | Equivalence level |
|---|---|---|---|
| Ansell Healthcare | GAMMEX Non-Latex PI | 20685755 – 20685790 | Comparable by category (not interchangeable 1:1) |
| Mölnlycke Health Care | Biogel PI | 40855 – 40890 | Comparable by category (not interchangeable 1:1) |
| Hartmann | Peha-isoprene latexfree powder-free | 942717 – 942724 | Comparable by category (not interchangeable 1:1) |
| Sempermed | Syntegra IR | SIR550 – SIR900 | Comparable by category (not interchangeable 1:1) |
There is no equivalence table validated by the manufacturer for this product; always compare dimensions, thicknesses, coating, standards (EN 455, MDR) and compatibility with the procedure before using any of these references as a substitute in a tender or purchasing process.
5. Selection tips and variants of interest
- Size selection: the series is available in sizes 5.5 to 9. If the fit is loose, consider the next size down in the same series (e.g. from 7 to 6.5, ref. MSG9065); if it is tight, go up a size (e.g. from 7 to 7.5, ref. MSG9075).
- Latex allergy: powder-free polyisoprene eliminates type I allergy; if contact dermatitis (type IV) is present, confirm tolerance to residual accelerators with the manufacturer’s technical data sheet.
- Precision surgery: if the procedure requires an even finer gauge, within the same Medline family the micro polyisoprene line (SensiCare® PI Micro, references MSG96xx) can be considered for greater tactile dexterity.
- Double gloving technique: for high-risk surgeries this type of glove can be combined with perforation detection systems, increasing safety against micro-perforations.
- Storage: store in a cool, dry place, protected from direct sunlight, heat sources, humidity and ozone, in its original packaging until use.
- Purchasing for centres: as this is a product on quotation, special conditions are offered for purchasing centres and hospitals by volume and scheduled delivery times; request a quote from our commercial team.





Reviews