Description
1. Introduction
The SensiCare PI Evolution surgical glove size 7.5 is the ideal solution for professionals seeking the feel, elasticity and fit of latex without the risks of natural rubber proteins. Made from high-performance synthetic polyisoprene (ISOLEX formulation), it offers a reliable sterile barrier, excellent tactile sensitivity and sustained comfort even during long procedures.
Each box contains 50 sterile single-use pairs, powder-free, with a synthetic polymer inner coating that facilitates donning even with slightly damp hands. The reference MSG9575 in size 7.5 allows the surgical block to be standardised with a product line of recognised quality for general surgery and invasive procedures.
2. Technical Explanation
Polyisoprene is a synthetic elastomer whose molecular structure replicates that of natural latex, resulting in a flexible, resistant and highly elastic glove, but free from latex proteins, eliminating the risk of type I (immediate) sensitisation. The PI Evolution variant combines polyisoprene with neoprene to improve chemical resistance and durability, while maintaining a contained gauge, making it especially suitable for general surgery.
Its powder-free finish with a molecularly bonded synthetic polymer inner coating prevents delamination and flaking during use. The rolled and fitted cuff adheres to the surgical gown and reduces slippage. It is certified as a class IIa medical device and as a category III personal protective equipment (PPE), with proven viral penetration resistance according to EN ISO 374-5.
3. Technical Specifications
Data verified against the official technical data sheet of the SensiCare PI Evolution series (references MSG95xx).
| Parameter | Value |
| Material | Synthetic polyisoprene + neoprene (ISOLEX formulation), latex-free |
| Type | Standard surgical glove, sterile, single-use |
| Finish | Powder-free, inner coating of synthetic polymer |
| Colour / surface | Cream · smooth finish |
| Size | 7.5 |
| Cuff design | Beaded and fitted, anti-slip |
| Viral penetration | Tested to EN ISO 374-5 |
| Regulatory standard | EN 455-1 / -2 / -3 / -4 · EN ISO 21420 |
| Classification | Medical device Class IIa · PPE Category III |
| Presentation | Box of 50 pairs (100 units) |
| Reference / SKU | MSG9575 |
Dimensional data for the series (MSG95xx):
| Parameter | Value |
| Fingertip thickness | 0.23 mm |
| Palm thickness | 0.20 mm |
| Cuff thickness | 0.17 mm |
| Length | 295 mm |
Size variants of the SensiCare PI Evolution series:
| Size | Reference | Presentation |
| 5.5 | MSG9555 | Box of 50 pairs |
| 6.0 | MSG9560 | Box of 50 pairs |
| 6.5 | MSG9565 | Box of 50 pairs |
| 7.0 | MSG9570 | Box of 50 pairs |
| 7.5 | MSG9575 | Box of 50 pairs |
| 8.0 | MSG9580 | Box of 50 pairs |
| 8.5 | MSG9585 | Box of 50 pairs |
| 9.0 | MSG9590 | Box of 50 pairs |
4. Equivalences and Cross-References
The following references belong to other manufacturers and have been verified against sources from authorised distributors and official catalogues. They match in category (sterile polyisoprene surgical glove, powder-free), size 7.5 and format of 50 pairs, but have design differences (inner coating, texture, formulation) that prevent them from being considered interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ansell Healthcare | GAMMEX Non-Latex PI | 20685775 (EU: 340057075) | Comparable by category (not interchangeable 1:1) | Powder-free synthetic polyisoprene, SureFit anti-roll-down cuff technology and micro-textured surface; verify thicknesses and coating against ISOLEX. |
| Mölnlycke Health Care | Biogel PI | 40875 | Comparable by category (not interchangeable 1:1) | Patented Biogel hydrating inner coating; part of the double-gloving puncture indication system; AQL 0.65; micro-textured surface. |
| Hartmann | Peha-isoprene latexfree | 942721 | Comparable by category (not interchangeable 1:1) | 100% synthetic ultra-thin polyisoprene, polymeric inner coating and micro-rough surface; reaches AQL level 0.65. |
| Sempermed | Syntegra IR | SIR750 | Comparable by category (not interchangeable 1:1) | Polyisoprene with fully anatomical shape and curved fingers, multi-layer synthetic inner coating; indicated for emergency and general surgery. |
There is no equivalence table validated by the manufacturer for this product; always check dimensions, thicknesses, coating, standards (EN 455, MDR) and compatibility with the procedure before using any of these references as a substitute in a tender or purchasing process.
5. Selection tips and variants of interest
- Size selection: size 7.5 is recommended for an approximate hand circumference of 90–100 mm. If the fit is loose, consider size 7.0 (MSG9570); if tight, move to size 8.0 (MSG9580).
- Latex allergy: powder-free polyisoprene eliminates type I allergy; if contact dermatitis (type IV) exists, it is advisable to confirm tolerance to residual accelerators with the manufacturer’s technical data sheet.
- Precision surgery: if the procedure requires an even finer gauge, consider the micro polyisoprene line (SensiCare PI Micro, ref. MSG9675 in size 7.5), with greater tactile dexterity for precision surgery.
- Double-gloving technique: for high-risk surgeries, this type of glove can be combined with a coloured inner glove in puncture detection systems, increasing safety against micro-perforations.
- Storage: store in a cool, dry place, protected from direct light, ozone and heat sources, in its original packaging until use.