Description
1. Maximum tactile sensitivity in a latex-free surgical glove
The sterile micro polyisoprene glove SensiCare PI Micro size 7.5 is indicated for healthcare professionals who need a thin, sterile, powder-free glove with the greatest possible tactile sensitivity in highly demanding procedures. Made from ISOLEX polyisoprene, it reproduces the elasticity, fit and feel of natural latex while eliminating the risk of allergy to latex proteins (type I allergy). Its powder-free synthetic polymer coating facilitates donning and avoids talc, reducing the risk of contamination of the surgical field and irritation to sensitive skin.
2. Technical Explanation
ISOLEX polyisoprene is a synthetic latex emulsion (cis-polyisoprene) that offers mechanical behaviour very similar to natural rubber: high elasticity, excellent recovery and tensile strength, but free of the protein impurities responsible for sensitisation. The micro format refers to a reduced thickness compared with the standard glove of the same family, designed for precision surgeries —neurosurgery, vascular, ophthalmic or plastic surgery— where every millimetre of touch counts. Being sterile, single-use and powder-free, it meets the requirements of a surgical glove: reliable barrier, controlled AQL and suitability for aseptic environments. It is a class IIa medical device intended for barrier protection in surgery and invasive procedures.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Material | Synthetic polyisoprene ISOLEX, 100 % natural latex-free |
| Finish | Micro (low thickness), powder-free |
| Coating | Powder-free synthetic polymer (facilitates donning) |
| Sterility | Sterile, single-use |
| Size | 7.5 |
| Use | High-precision surgical and clinical |
| Presentation | Box of 50 pairs (100 units) |
| Reference | MSG9675 |
Size variants of the SensiCare PI Micro series
| Size | Reference | Presentation |
|---|---|---|
| 5.5 | MSG9655 | Box of 50 pairs |
| 6.0 | MSG9660 | Box of 50 pairs |
| 6.5 | MSG9665 | Box of 50 pairs |
| 7.0 | MSG9670 | Box of 50 pairs |
| 7.5 | MSG9675 | Box of 50 pairs |
| 8.0 | MSG9680 | Box of 50 pairs |
| 8.5 | MSG9685 | Box of 50 pairs |
| 9.0 | MSG9690 | Box of 50 pairs |
For zone-specific thicknesses (finger, palm, cuff), breaking forces and specific AQL values for this series, refer to the manufacturer’s official technical data sheet available on the product page.
4. Equivalences and Cross-References
The following references are sterile surgical gloves made of synthetic polyisoprene, powder-free and in size 7.5, supplied in boxes of 50 pairs. They match in material, size, sterility and finish, but each manufacturer applies its own formulation, thickness and coating, so they are classified as comparable by category and not interchangeable 1:1 without prior technical validation.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Ansell | GAMMEX Non-Latex PI Micro | 20685975 (UE: 340057075) | Comparable by category (not interchangeable 1:1) | Micro polyisoprene 15 % thinner, micro-textured finish and cuff anti-roll technology; verify thickness and coating |
| Mölnlycke | Biogel PI UltraTouch | 41175 | Comparable by category (not interchangeable 1:1) | Approx. 15 % thinner than standard Biogel PI, with Biogel coating for donning with wet or dry hands; straw colour and beaded cuff |
| Hartmann | Peha-isoprene latexfree | 942721 | Comparable by category (not interchangeable 1:1) | Very fine polyisoprene with micro-textured surface and inner polymeric coating; achieves AQL level 0.65 |
| Sempermed | Syntegra IR | SIR750 | Comparable by category (not interchangeable 1:1) | Polyisoprene with fully anatomical shape and curved fingers, multi-layer synthetic inner coating; indicated for emergency and precision surgery |
There is no equivalence table validated by the manufacturer for this product; always cross-check dimensions, thicknesses, coating, regulations (EN 455 / MDR) and compatibility with the procedure before using any of these references as a substitute in a tender or purchasing process.
5. Selection tips and variants of interest
To choose the right glove, consider, in this order: (1) allergy or sensitivity to latex and chemical accelerators —powder-free polyisoprene eliminates type I allergy, although it is advisable to confirm the absence of accelerators if there is type IV dermatitis—; (2) type of procedure: micro formats are reserved for maximum precision surgeries, while for general surgery you can opt for the standard glove of the same range (SensiCare PI Evolution, ref. MSG9575 in size 7.5) at a lower cost; (3) need for double gloving: if you use the double-gloving technique, the dark green inner glove with puncture indicator is the recommended safety option; (4) size and coating: check the fit and try on a pair before consolidating the order. For purchasing centres and hospitals, special conditions are offered by volume and scheduled delivery times; request a quote from our sales team.