Sterile Micro Polyisoprene Surgical Glove, Powder-Free SensiCare PI Micro – Size 5.5 | Box of 50 Pairs (Ref. MSG9655)

72,25 €

Sterile micro polyisoprene surgical glove, powder-free SensiCare PI Micro, made from ISOLEX synthetic polyisoprene with a powder-free polymer inner coating. Its micro format (low thickness) offers superior tactile sensitivity and quick donning even with damp hands, while maintaining the fit and performance of latex without the risk of type I allergy. Size 5.5, ideal for small hands. Presentation in box of 50 pairs (100 units). Ref. MSG9655. Suitable for operating theatre, precision surgery and hospital purchasing groups; see special volume conditions.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
MSG9655

Description

1. Introduction

The SensiCare PI Micro sterile powder-free polyisoprene glove in size 5.5 is the choice of the professional who needs a thin, sterile, powder-free glove with maximum tactile sensitivity in high-demand procedures. Manufactured from ISOLEX polyisoprene, it reproduces the elasticity, fit and feel of natural latex while eliminating the risk of latex protein allergy (type I allergy). Its powder-free finish and inner synthetic polymer coating facilitate donning, eliminate talc and reduce the risk of contamination of the surgical field and irritation on sensitive skin. Presented in a dispenser box of 50 pairs, it is the ideal solution for operating theatres, precision surgery departments and hospital purchasing centres.

2. Technical Explanation

ISOLEX polyisoprene is a synthetic latex (cis-polyisoprene) whose mechanical behaviour is very similar to that of natural rubber: high elasticity, excellent recovery and tensile strength, but free from the protein impurities responsible for sensitisation. The micro format refers to a reduced thickness compared to the standard glove of the same family —0.20 mm at the finger—, designed for maximum precision surgeries such as neurosurgery, vascular surgery, ophthalmology or plastic surgery, where every tenth of a millimetre of feel counts. Its inner synthetic polymer coating allows rapid donning even with damp hands, while the anatomical cuff with bead prevents the glove from rolling down towards the palm. Being sterile, single-use and powder-free, it meets the requirements of a surgical glove: reliable barrier, controlled AQL and suitability for aseptic environments. It is a class IIa medical device intended for barrier protection in surgery and invasive procedures.

3. Technical Specifications

Data verified against the official technical data sheet of the SensiCare PI Micro series (references MSG96xx).

Characteristic Specification
Material Synthetic polyisoprene ISOLEX, 100 % natural latex-free
Finish Micro (low thickness), powder-free, smooth surface (EN 455-3 / ISO 21171)
Inner coating Powder-free synthetic polymer (facilitates donning)
Colour Cream
Mould design Anatomical, straight fingers and independent thumb
Cuff design Anatomical with anti-roll bead
Sterility Sterile by gamma radiation (SAL 10⁻⁶), single-use
Class Class IIa medical device (MDR), compliant with EN 455-1/2/3
Size 5.5
Presentation Dispenser box of 50 pairs (100 units) · 4 boxes per carton (200 pairs)
Reference MSG9655

Thicknesses of the series (ASTM D3577, minimum 0.10 mm):

Zone Thickness
Finger 0.20 mm
Palm 0.18 mm
Cuff 0.15 mm

Mechanical and barrier performance of the series: breaking force before ageing (EN 455-2, ≥ 9 N) of 13.1 N; breaking force after accelerated ageing (7 days at 70 °C, ≥ 9 N) of 12 N; absence of holes (EN 455-1) with AQL 0.65; viral penetration passed (ISO 16604 / ASTM F1671); latex protein-free (EN 455-3 / ASTM D5712); ZDEC and ZMBT accelerators below detectable limits; chemical resistance EN 16523-1 and cytostatics ASTM D6978. Shelf life: 35 months from date of manufacture. Store in a dry place, protected from direct sunlight, heat sources, humidity and ozone.

Size variants of the SensiCare PI Micro series:

Size Reference Presentation
5.5 MSG9655 Box of 50 pairs
6.0 MSG9660 Box of 50 pairs
6.5 MSG9665 Box of 50 pairs
7.0 MSG9670 Box of 50 pairs
7.5 MSG9675 Box of 50 pairs
8.0 MSG9680 Box of 50 pairs
8.5 MSG9685 Box of 50 pairs
9.0 MSG9690 Box of 50 pairs

4. Equivalences and Cross-References

The following references are sterile synthetic polyisoprene surgical gloves, powder-free and in size 5.5, presented in 50 pairs per box. They match in material, size, sterility and finish, but each manufacturer applies its own formulation, thickness and coating, so they are classified as comparable by category and not interchangeable 1:1 without prior technical validation.

Manufacturer / Brand Family / Model Code / SKU (size 5.5) Equivalence Level Technical Differences / Remarks
Ansell GAMMEX Non-Latex PI Micro 20685955 (EU: 340057055) Comparable by category (not interchangeable 1:1) Micro polyisoprene approx. 15% thinner than standard, micro-textured surface and anti-roll cuff technology (SureFit); verify thicknesses and coating
Mölnlycke Biogel PI UltraTouch 41155 Comparable by category (not interchangeable 1:1) Polyisoprene approx. 15% thinner than standard Biogel PI, with Biogel coating for donning with wet or dry hands; straw colour, micro-textured surface and beaded cuff
Hartmann Peha-isoprene latexfree 942717 Comparable by category (not interchangeable 1:1) Ultra-thin 100% synthetic polyisoprene, micro-rough surface and inner polymeric coating; achieves an AQL level of 0.65
Sempermed Syntegra IR SIR550 Comparable by category (not interchangeable 1:1) Polyisoprene with fully anatomical shape and curved fingers, multi-layer inner synthetic coating; indicated for emergency, ophthalmology and paediatrics

There is no equivalence table validated by the manufacturer for this product; always check dimensions, thicknesses, coating, standards (EN 455-1/2/3/4, MDR) and compatibility with the procedure before using any of these references as a substitute in a tender or purchasing process.

5. Selection tips and variants of interest

  • Allergy or sensitivity: powder-free polyisoprene eliminates type I latex allergy; if there is contact dermatitis (type IV), tolerance to residual accelerators should be confirmed, which in this series are below detectable limits.
  • Procedure type: the micro format is reserved for maximum precision surgeries (neurosurgery, vascular, ophthalmology or plastic surgery); for general surgery you may opt for the standard glove of the same range (SensiCare PI Evolution, ref. MSG9555 in size 5.5) at a more contained cost.
  • Double gloving: if using the double gloving technique, the dark green inner glove with puncture indicator is the recommended safety option.
  • Size and fit: size 5.5 fits very small hands; check the fit on a pair before confirming the order.
  • Volume purchasing: special volume conditions and scheduled delivery times are offered to purchasing groups and hospitals; request a quote from our sales team.

Additional information

Material

ISOLEX synthetic polyisoprene (100% natural latex-free)

Size

5.5

Finish

Micro (low thickness), powder-free

Inner coating

Powder-free synthetic polymer

Sterilisation

Gamma radiation (SAL 10⁻⁶)

Use

Sterile, single-use

Product class

Class IIa medical device (MDR)

Finger thickness

0.20 mm

Palm thickness

0.18 mm

Cuff thickness

0.15 mm

AQL holes

0.65 (EN 455-1)

Breaking force

13.1 N (before ageing) / 12 N (after ageing)

Regulatory standard

EN 455-1/2/3, ISO 16604, ASTM F1671, ASTM D3577, EN 16523-1, ASTM D6978

Presentation

Box of 50 pairs (100 units); 4 boxes per carton

Reference

MSG9655

Color

Beige

Documentation

Reviews

There are no reviews yet.

Be the first to review “Sterile Micro Polyisoprene Surgical Glove, Powder-Free SensiCare PI Micro – Size 5.5 | Box of 50 Pairs (Ref. MSG9655)”

Your email address will not be published. Required fields are marked *