Description
1. Introduction
The nitrile examination gloves SensiCare® Free from Medline offer the end user a latex-free solution without chemical accelerators, which minimises the risk of skin deterioration and adverse allergic or cutaneous reactions, both type I (latex) and type IV (chemical accelerators). It is the safest option for healthcare professionals who need a reliable barrier without sacrificing comfort, tactile sensitivity and dexterity throughout the working day. A product from the Medline family, available in sizes from extra small (XS) to extra large (XL).
2. Technical explanation
This single-use examination glove is made of nitrile, a synthetic copolymer that reproduces the elasticity and resistance of natural latex without containing its allergenic proteins. Its Accelerator Free formulation eliminates the chemical accelerators commonly used to speed up the manufacturing process, bind the raw materials and ensure a durable and elastic glove; by omitting them, the risk of contact dermatitis on sensitive skin is significantly reduced. The glove offers a comfortable fit, reliable grip and excellent tactile sensitivity, with a thickness of 0.07 mm at the palm, 0.09 mm at the finger and 0.05 mm at the cuff, and a length of 241 mm. It is certified as personal protective equipment (PPE), tested in accordance with EN455, with resistance to viral penetration according to EN374-5 and suitable for food contact. It is non-sterile.
3. Technical Specifications
They are generally recommended for use in areas where examination gloves are of greater importance, such as trauma units, or in areas that handle aggressive chemicals or liquid immersion. The main features and advantages are: comfortable fit, reliable grip, light blue colour, PPE certification, colour codes by size and excellent sensitivity.
Available references
| Reference | Size | Units per box | Units per pack |
|---|---|---|---|
| MDSFREE-XS | XS | 2000 | 200 |
| MDSFREE-S | S | 2000 | 200 |
| MDSFREE-M | M | 2000 | 200 |
| MDSFREE-L | L | 2000 | 200 |
| MDSFREE-XL | XL | 1800 | 180 |
Manufacturer’s specifications
| Parameter | Value |
|---|---|
| Glove material | Nitrile |
| Allergenic potential | Accelerator Free (without accelerators) |
| Chemical accelerators | None |
| EN374-5 Viral penetration | Yes |
| Tested in accordance with EN455 | Yes |
| Certified as PPE | Yes |
| Anatomical fit | No |
| Material thickness at the finger | 0.09 mm |
| Material thickness at the palm | 0.07 mm |
| Material thickness at the cuff | 0.05 mm |
| Length | 241 mm |
| Inner coating method | No |
| Suitable for food contact | Yes |
| Sterile | No |
4. Equivalences and Cross-References
The SensiCare® Free range from Medline is identified with the P-FA12K family and is marketed under the references MDSFREE-XS, MDSFREE-S, MDSFREE-M, MDSFREE-L and MDSFREE-XL, in addition to the internal code MDLP-FA12K and its variants MDLMDSFREE-XS, MDLMDSFREE-S, MDLMDSFREE-M, MDLMDSFREE-L and MDLMDSFREE-XL. In the Cahnos catalogue of nitrile examination gloves there are other comparable families by category (not interchangeable 1:1), such as the Sanic Ultra Grip series (G13861, G13871, G13881, G13891), the biodegradable Sanic gloves (G2230 to G2233), the high-sensitivity SANYC Sensitive White line (G00270 to G00274) and the extra-strong blue gloves (G10001). The differentiating advantage of the SensiCare® Free over these alternatives is its formulation without chemical accelerators, especially indicated for users with sensitive skin or contact allergies.
5. Selection tips and variants of interest
To choose the correct size, measure the circumference of the palm at the base of the fingers with a flexible tape measure: the available sizes range from XS to XL, covering from small hands to extra large. A size that is too tight limits mobility and one that is excessively wide compromises grip, so it is recommended to complete the stock with several sizes of the same family (MDSFREE-XS to MDSFREE-XL) to ensure the proper fit for all staff. This glove is the ideal choice when barrier protection is needed for users with sensitive skin, latex allergy or sensitivity to chemical accelerators, as well as in trauma areas or where aggressive chemicals are handled. It is a single-use, non-sterile product, and is sold on quotation; consult your Cahnos sales advisor for terms and availability.