Description
1. Introduction
Medline sterile nitrile examination gloves ensure optimal patient care when sterile technique is appropriate, without compromising the comfort and safety of the professional. They are especially suitable for minor non-invasive procedures in emergency departments, childbirth and delivery, dermatology and wound care. A reliable protection solution that combines sterility, tactile sensitivity and resistance, designed for demanding healthcare environments.
2. Technical explanation
Made from nitrile, a synthetic latex-free copolymer that eliminates the risk of allergies to natural rubber and its allergenic proteins, these gloves feature a long cuff that increases forearm coverage and protects the professional during procedures, as well as textured fingertips that improve grip and handling of instruments. Their powder-free formulation reduces the risk of particle contamination and minimises the transmission of germs in the work environment. They are sterilised by gamma irradiation and are presented ambidextrous, in pairs, in small pocket-type packaging that facilitates compliance with sterility protocols. Their reinforced finger thickness (0.14 mm) provides additional resistance in the areas of greatest wear.
3. Technical Specifications
Medline sterile nitrile examination gloves are packaged powder-free in pairs, in boxes of 300 units (packs of 50 units per inner bag). Available in sizes S, M, L and XL.
Available references
| Reference | Size | Units per box | Units per pack |
|---|---|---|---|
| MDS2297 | XL | 300 | 50 |
| MDS2294 | S | 300 | 50 |
| MDS2295 | M | 300 | 50 |
| MDS2296 | L | 300 | 50 |
Specifications
| Characteristic | Specification |
|---|---|
| Brand | Medline |
| Medline family | P-GR45M |
| Reference Cahnos (SKU) | MDLP-GR45M |
| Glove material | Nitrile |
| Allergenic potential | Latex-free |
| Chemical accelerators | Carbamates |
| Sterility | Yes |
| Sterilisation method | Gamma irradiation |
| Use | Examination, single-use, ambidextrous, powder-free |
| EN 374-5 Viral penetration | Yes |
| Tested in accordance with EN 455 | Yes |
| Certified as personal protective equipment | Yes |
| Anatomical fit | No |
| Inner coating method | No |
| Material thickness at the finger | 0.14 mm |
| Material thickness at the palm | 0.11 mm |
| Material thickness at the cuff | 0.09 mm |
| Extra length | 302 mm |
| Suitable for food contact | No |
4. Equivalences and Cross-References
This product belongs to the Medline P-GR45M family of sterile nitrile examination gloves. In addition to the main reference (SKU MDLP-GR45M), sizes are identified by the factory references MDS2294 (S), MDS2295 (M), MDS2296 (L) and MDS2297 (XL), which are also marketed under the packaging variants MDLMDS2294, MDLMDS2295, MDLMDS2296 and MDLMDS2297. Within the Medline catalogue of nitrile examination gloves, this sterile range is complemented (without being interchangeable 1:1 without validation) with other comparable lines by category: Generation Pink® gloves (family P-ZD49T) and Restore® Sense gloves with colloidal oatmeal (family P-RF31X), both non-sterile, indicated for general examination and sensitive skin respectively. Any substitution in tenders or bids must be validated size by size and property by property with the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
Select the size according to the professional’s fit: S for small hands, M for medium hands (the most common in healthcare settings), L for large hands and XL for very large hands. The glove should fit without constricting, preserving full mobility of the fingers; a size that is too tight limits dexterity and one that is excessively loose compromises grip. As this is a sterile glove for sterile technique in minor non-invasive procedures, always check the integrity of the packaging before use and follow the centre’s asepsis guidelines. For general examination without sterility requirements, the Generation Pink® nitrile examination glove range (P-ZD49T) may be considered; if greater comfort is required for sensitive skin with frequent washing, the Restore® Sense family (P-RF31X) is an alternative. For B2B volume conditions, supply agreements or validation of equivalents, contact the technical-commercial team at Cahnos; this product is sold on quotation.














Reviews