Nasal oxygen cannula ref. 34172 – Oxygen therapy nasal cannula, class IIa medical device (not suitable for ref. 33698)

0,86 €

The nasal oxygen cannula (ref. 34172) is a nasal cannula system for low-flow oxygen therapy, designed for the safe and comfortable administration of supplemental oxygen in adults in hospitals, clinics, care homes and home care. Spectacle-type assembly with stable fixation, nasal prongs with constant flow and connection to flowmeters, concentrators and cylinders. Medical device of class IIa, non-sterile, single-use. Not suitable for use with reference 33698. Sales unit: 1 unit. References: Ref. 34172 · SKU Cahnos GM34172.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM34172

Description

1. Introduction

Nasal oxygen cannulas The manufacturer ref. 34172 (SKU Cahnos GM34172) are the professional solution for low-flow oxygen therapy in patients requiring a constant and well-tolerated supply of supplemental oxygen. Their spectacle-type design, with stable fixation on the head, keeps the nasal prongs in the correct position during therapy and improves comfort in prolonged treatments. They are a medical device, ready to be incorporated into the usual oxygen administration circuits of your centre: hospitals, emergency departments, wards, care homes and home oxygen therapy.

2. Technical explanation of the device

Nasal oxygen cannulas (occhiali ossigeno / nasal cannulas) are the most widespread low-flow oxygen administration system in clinical practice: two nasal prongs are placed in the patient’s nostrils and oxygen reaches the nasal distributor from the source (flowmeter, concentrator or cylinder) through the connecting tube. The spectacle-type assembly incorporates an additional fastening that stabilises the device without pressing on the septum, reducing displacement and favouring tolerance in long-term therapies. It is a single-use, disposable, non-sterile medical device that must be replaced according to the centre’s protocol to prevent cross-contamination.

3. Technical Specifications

Reference 34172
SKU Cahnos GM34172
Product type Nasal oxygen cannula (oxygen therapy nasal cannulas)
Use Low-flow oxygen therapy
Compatibility Not suitable for use with reference 33698

Product data

Manufacturer GIMA
Sales unit 1 pc
Device type Medical device
Device class II A
CND R0301020301
GMDN 35201
EAN 6970741240130

4. Equivalences and Cross-References

There is no official equivalence table published by the manufacturer cross-referencing reference 34172 with products from other brands. The following references are listed as comparable at category level (adult oxygen therapy nasal cannulas), verified in other manufacturers’ catalogues; they are not interchangeable 1:1 and must be validated field by field with the technical department before any substitution.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Observations
P.J. Dahlhausen & Co. GmbH Adult oxygen nasal cannula (prongs), standard connector 01.000.01.750 Comparable by category (not interchangeable 1:1) Adult cannula with 210 cm tube, straight tip, DEHP/DOP-free, non-sterile; differs in fixation design and presentation.
Medline (Hudson RCI / Teleflex) Softech Plus adult, Star Lumen tube 1870 Comparable by category (not interchangeable 1:1) Adult cannula without DEHP with anti-kink five-channel tube of 210 cm, standard connector, flow rate 4 l/min; differs in fixation design and presentation.
Salter Labs (AirLife) Adult soft nasal cannula, 7 ft tube 16SOFT-7-50 Comparable by category (not interchangeable 1:1) Flexible PVC with curved prongs and three-channel safety tube of 2.13 m, flow up to 6 l/min; differs in design and presentation.

There is no equivalence table validated by the manufacturer for this reference; consult the technical department of Cahnos before using this information in a tender or stock substitution.

5. Selection tips and variants of interest

Before placing the order, confirm the compatibility of the nasal cannula with your centre’s supply system: reference 34172 is not suitable for use with reference 33698, so you must verify the oxygen source, flowmeter, concentrator or humidifier with which it will be combined. For patients requiring longer tubing runs or systems with anti-kink tubing, nasal cannulas from the OS/12 families (e.g. OS/12A of 160 cm, OS/12AL with flexible tubing or OS/12ATL of 4.5 m) available in the catalogue may be considered. Always use a new nasal cannula per patient to prevent cross-contamination, respect the prescribed flow rate and store the product in a cool, dry place. For quotations and B2B volume conditions, contact our technical-commercial team at Cahnos.

Additional information

Manufacturer reference

34172

Product type

Nasal oxygen cannula (oxygen therapy nasal cannulas)

Use

Low-flow oxygen therapy, single-use

Compatibility

Not suitable for use with reference 33698

CND code

R0301020301

GMDN code

35201

EAN

6970741240130

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II a

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Nasal oxygen cannula ref. 34172 – Oxygen therapy nasal cannula, class IIa medical device (not suitable for ref. 33698)”

Your email address will not be published. Required fields are marked *