High-Level Disinfectant Instrunet Anioxyde 1000 Peracetic Acid 5 L – Phéra System for Clinical, Surgical Instruments and Endoscopes

95,22 €

High-level disinfectant Instrunet Anioxyde 1000 in a 5-litre container with activator, based on the Phéra system for extemporaneous production of peracetic acid. Aldehyde-free alternative, does not fix proteins and highly compatible with heat-sensitive material, endoscopes and medical-surgical instruments: complete microbicidal spectrum in just 5 minutes of contact and active solution for up to 14 days with control using test strips. Price per unit. Ref. CAH2917.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
CAH2917

Description

Instrunet Anioxyde 1000 Instrument Disinfectant 5 Lts

Anioxyde 1000 is the professional reference solution for high-level cold disinfection of clinical instruments, medical-surgical material, endoscopes and heat-sensitive medical devices. Thanks to the Phéra system, it generates peracetic acid extemporaneously and in a controlled manner, without the need for aldehydes, ensuring effective disinfection that is safe for materials and respectful of staff and patients.

How does Anioxyde 1000 work?

Anioxyde 1000 uses the patented Phéra system, which produces peracetic acid in the immersion bath itself by mixing the base solution with the corresponding activator. The result is a high-level disinfectant solution with approximately 1500 ppm of peracetic acid, stable for 14 days and verifiable with specific control strips. Being formulated without aldehydes, it does not fix residual proteins and, as it does not contain acetic acid, it has a neutral pH and excellent compatibility with metals, rubbers, lenses and polymers of endoscopic equipment.

Technical specifications

Characteristic Specification
Active ingredient Peracetic acid generated in situ (Phéra system); 1500 ppm after activation, control threshold 900 ppm
Disinfection level High level / cold chemical sterilant for heat-sensitive material
Microbicidal spectrum Bactericidal, fungicidal, virucidal, mycobactericidal and sporicidal in 5 minutes of contact
Type of disinfection High level, effective against a wide range of pathogens
Field of application Clinical and surgical instruments, endoscopes, medical-surgical material and medical devices
Compatible materials Heat-sensitive materials and endoscopic equipment; non-corrosive, does not fix proteins
pH Neutral (5.5–7.0)
Directions for use Prior cleaning and rinsing; mix base and activator; wait 30 minutes for activation; immerse for 5 minutes; rinse with sterile or filtered water and dry
Bath stability 14 days after activation, with periodic control using peracetic acid strips
Presentation 5-litre container (base solution + activator bottle)
Regulation CE marking as a medical device, in accordance with Directive 93/42/EEC

Equivalences and cross-references

Anioxyde 1000 belongs to the high-level disinfection range of Laboratorios Anios (Ecolab), distributed in Spain by Instrunet. It is the aldehyde-free alternative to glutaraldehyde, so in the Cahnos catalogue its direct equivalent in spectrum and application is the disinfectant Steranios 2% glutaraldehyde (ref. CAH5168) and the high-level disinfectant Opaster’Anios based on OPA at 0.55% (ref. CAH4838). To complete the reprocessing circuit, prior cleaning with the enzymatic detergent Aniosyme Sinergy (ref. CAH4840) or the cleaning disinfectant Aniosyme x3 (ref. CAH2922) is recommended, as well as surface disinfection of the room with Surfanios Premium (ref. CAH5059).

Selection tips and variants of interest

Anioxyde 1000 is the ideal choice when high-level cold disinfection is needed for instruments that cannot withstand heat, with short contact times and simple bath control using peracetic acid test strips. Before each cycle, carry out prior cleaning with an enzymatic detergent and abundant rinsing to remove organic residues that may interfere with the disinfectant action; check the bath concentration before starting and after interruptions, and replace it within the 14-day useful life. For high reprocessing volumes, consider complementing the range with 1-litre formats of enzymatic detergents (Jet Plus ref. CAH4071 or Enzimático GPL ref. CAH3903) and, if you need special institutional purchasing conditions or technical advice, our technical-commercial team at Cahnos is at your disposal.

Additional information

Active ingredient

Peracetic acid generated in situ (Phéra system)

Disinfection level

High level / cold chemical sterilant

Active concentration

1500 ppm after activation (control threshold: 900 ppm)

Microbicidal spectrum

Bactericidal, fungicidal, virucidal, mycobactericidal and sporicidal in 5 minutes

Contact time

5 minutes

Activation time

30 minutes after mixing base and activator

Bath stability

14 days after activation

Control

Peracetic acid test strips (not included)

Presentation

5-litre container with activator (2-component system)

Application

Clinical and surgical instruments, endoscopes, heat-sensitive materials and medical devices

Compatibility

Heat-sensitive materials and endoscopic equipment; aldehyde-free, does not fix proteins, neutral pH

Regulatory standard

CE marking, medical device (Directive 93/42/EEC)