We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Replacement filter for EOLO nebuliser (Ref. 28095) – Box of 20 units | Aerosol therapy spare part

7,13 €

Original replacement filter for the compressor nebuliser EOLO (Ref. 28095), the replacement part that keeps the air circuit clean and protects the device’s compressor. It is supplied in a box of 20 units, the ideal format to guarantee a continuous maintenance plan in pulmonology, paediatrics, primary care practices and home use. A saturated filter reduces the air flow rate, decreases the nebulisation rate and compromises drug deposition in the airways; therefore, replacing it periodically is essential to preserve the performance of aerosol therapy and extend the compressor’s service life. Original replacement part (spare part) of the manufacturer. For large orders, you can request a quote.

Sales unit: caja de 20
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM28095

You will also find it in

Description

Original replacement filter for the EOLO nebuliser (Ref. 28095). Replacement part (spare part) of the manufacturer, specifically designed for the EOLO piston compressor nebuliser (Ref. 28097 / 28091). It is supplied in a box of 20 units to ensure continuous replacement of the device’s air filter. Product marketed by Cahnos. For large orders, you can request a quote.

1. Commercial Introduction

Keep your EOLO nebuliser in optimal condition with the original replacement filter (Ref. 28095). It is the maintenance consumable that ensures the air drawn in by the compressor reaches the nebulisation circuit clean, protecting both the mechanics of the device and the quality of the administered medication. Its presentation in a box of 20 units makes it the most practical and cost-effective option for health centres, pulmonology and paediatrics practices, pharmacies and patients who use aerosol therapy continuously at home.

2. Technical Explanation

In a compressor nebuliser, the air filter is placed between the pump’s air intake and the pneumatic circuit, retaining particles, dust and other impurities before the air passes through the nebuliser chamber. Keeping the filter in good condition and replacing it periodically according to the manufacturer’s indications prevents compressor overload, preserves the flow and outlet pressure (the EOLO operates at 1.1 bar with a flow rate of 14 l/min and generates particles smaller than 5 µm) and reduces equipment noise. A saturated or deteriorated filter reduces the nebulisation rate and compromises drug deposition in the airways, so regular replacement is a key factor for the effectiveness of aerosol therapy and the lifespan of the nebuliser.

3. Technical Specifications

Product data verified against the manufacturer’s catalogue:

Manufacturer GIMA
Manufacturer reference 28095
Sales unit Box of 20 pieces (box of 20 pcs)
Device type Spare part (spare part)
EAN 8023279280951

Available references

SKU Cahnos Reference Description
GM28095 28095 Replacement filter for EOLO nebuliser – box of 20 units (this product)

Compatibility

Equipment Reference
Piston compressor nebuliser EOLO (230 V, standard plug) 28097 (GM28097)
Piston compressor nebuliser EOLO (230 V, British plug) 28091 (GM28091)

4. Equivalences and Cross-References

Reference 28095 corresponds to the original replacement filter intended for the EOLO nebuliser (codes 28097 / 28091), according to the Product_DB catalogue. No validated 1:1 equivalence with filters from other manufacturers has been found in reliable sources: as it is a consumable of proprietary design, it is recommended to use exclusively the original reference to ensure the fit and expected performance of the device. Within the ecosystem available at Cahnos, other spare parts in the nebulisation range include the replacement filter for the Happyneb, Betaneb and Hospineb families (Ref. 28145), the 1 m PVC connection tube (Ref. 28158) and the NEB nebuliser chamber (Ref. 28140).

5. Selection tips and variants of interest

To keep the EOLO nebuliser operational and effective, periodically check the condition of the air filter and replace it according to the manufacturer’s maintenance plan; the box of 20 units allows you to plan replacement in advance without interrupting clinical activity. Complete the equipment’s spare parts supply with the original accessories from the same range: nebuliser chamber (Refs. 28139 / 28140), adult and paediatric masks (Refs. 28146 and 28147), mouthpiece and nasal piece (Ref. 28157), complete nebulisation kit (Ref. 28138) and PVC connection tube (Ref. 28158). For volumes, supplies or tenders, request a quote from your technical-commercial advisor at Cahnos.

Additional information

Manufacturer

GIMA S.p.A.

Manufacturer reference

28095

Sales unit

Box of 20 pieces (box of 20 pcs)

Device type

Spare part (spare part)

Compatibility

Piston compressor nebuliser EOLO (Refs. 28097 / 28091)

Presentation

Box of 20 units

EAN

8023279280951

Use

Periodic maintenance of the nebuliser air filter

Presentacion

Box of 20

Tipo dispositivo

Spare part

Documentation

📄 DatasheetEnglish PDF

Reviews

There are no reviews yet.

Be the first to review “Replacement filter for EOLO nebuliser (Ref. 28095) – Box of 20 units | Aerosol therapy spare part”

Your email address will not be published. Required fields are marked *