Description
Nebjet 3A nebuliser bottle with double diffuser
1. Commercial Introduction
The Nebjet 3A nebuliser bottle from 3A Health Care is the reference nebulisation cup for administering aerosol therapy in clinics, health centres and at home. Its double-effect diffuser system, located at the base of the nebuliser, enhances nebulisation and makes the most of the medication, minimising residual volume. A reliable, easy-to-handle replacement designed for routine use and compatible with daily inhaled therapy for adult and paediatric patients.
2. Technical explanation
In a compressor nebuliser, pressurised air passes through the nebuliser bottle, where the liquid drug is fragmented into respirable microparticles. The double-effect diffuser acts as a booster system located at the base of the cup, optimising drug dispersion and generating a fine, uniform mist. The mouthpiece, supplied separately, channels the aerosol into the oral cavity, where the drug is deposited in the respiratory tract. With a respirable fraction below 5 µm of 75% and a residual volume of only 0.7 ml, the Nebjet ensures effective use of each session and optimal particle performance for reaching the deep airways.
3. Technical Specifications
Features verified against the manufacturer’s official catalogue 3A Health Care.
Particle size (MMAD)
| Operating flow | MMAD |
| 5 l/min | 2.61 µm |
| 7.5 l/min | 2.03 µm |
Technical data for the nebuliser bottle
| Parameter | Value |
| Capacity | 12 ml |
| Respirable fraction (< 5 µm) | 75 % |
| Residual volume | 0.7 ml |
| Nebulisation system | Double-effect diffuser |
| Administration mouthpiece | Supplied separately |
| Recommended use | Routine use |
4. Equivalences and Cross-References
This product corresponds to the manufacturer’s reference ABM-NEBJET-BOTELLA-NEBULIZADORA-DOBLE-143F01 from 3A Health Care, distributed by Cahnos on a quotation basis. Within the aerosol therapy catalogue, it is related to the Nebjet nebuliser ampoule with double Venturi effect (Ref. 28164, SKU GM28164), standard in the Happyneb I, Happyneb III and Betaneb equipment, as well as to the Nebjet mouthpiece (Ref. 28166, SKU GM28166) and the replacement filter (Ref. 28145). No validated 1:1 equivalence table with bottles from other manufacturers is available from reliable sources; we recommend verifying the compatibility of the cup with your compressor before replacement and consulting our technical-commercial team for any questions regarding fit or performance.
5. Selection tips and variants of interest
To choose the right nebuliser cup, consider: 1) the operating flow of your compressor: at 5 l/min an MMAD of 2.61 µm is obtained and at 7.5 l/min of 2.03 µm, both in the respirable range; 2) the capacity of 12 ml, suitable for standard doses of bronchodilators, mucolytics and saline solution; and 3) the administration mouthpiece, which must be ordered separately to complete the system. For maintenance of the nebulisation circuit, combine this replacement with the air filter and patient contact parts from the same range. Periodically check the condition of the diffuser and replace the part if it shows blockages or wear to maintain therapy effectiveness. This product is sold on a quotation basis: contact your technical-commercial advisor at Cahnos for terms, volumes or tenders.