Description
1. Introduction
The Omron M7 Intelli IT AFib (HEM-7380T1-EBK) is one of the most advanced upper-arm blood pressure monitors in the Omron range for self-monitoring of blood pressure and home screening for arrhythmias. It combines the clinically validated accuracy of Omron Healthcare with smart functions that make measurement easier and improve follow-up of hypertensive patients: detection of atrial fibrillation with each measurement, 360° Intelli Wrap cuff, triple measurement with average and Bluetooth connectivity with the OMRON Connect app.
It is the recommended choice for pharmacies, orthopaedic shops, home care services and health education programmes that need a reliable device to document patient progress and share reports with healthcare professionals.
2. Technical explanation of the equipment
The device uses the oscillometric method of non-invasive measurement: during controlled cuff deflation it detects oscillations of the arterial wall and converts them into digital values for systolic and diastolic pressure and pulse rate. The Intellisense™ technology regulates inflation pressure using fuzzy logic and an electric pump, detects irregular heartbeats and automatically decides whether the result is reliable or should be repeated, showing only accurate readings.
The preformed 360° Intelli Wrap cuff (arm circumference 22-42 cm, in nylon and polyester) wraps the entire circumference of the arm, so the reading is accurate from any position. The monitor incorporates a cuff placement guide, body movement detector, advanced positioning sensor and hypertension indicator. Thanks to the Intellisense AFib algorithm, it analyses the heart rhythm with each measurement and alerts to possible atrial fibrillation, recommending repeating the measurement and consulting a doctor. The AFib alert should be interpreted as screening: only a doctor can confirm the diagnosis by ECG.
The readings are synchronised via Bluetooth with the OMRON Connect app (iOS and Android), which allows monitoring parameters, creating personalised programmes, downloading and sharing data, and comparing each measurement with previous readings.
3. Technical Specifications
Product data
| Brand | OMRON |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II A |
| CND | Z1203020501 |
| EAN | 4015672113923 |
Main characteristics
| Parameter | Specification |
|---|---|
| Model / Reference | Omron M7 Intelli IT AFib / HEM-7380T1-EBK |
| Set type | Automatic digital arm blood pressure monitor (oscillometric method) |
| Measurement method | Oscillometric with Intellisense technology (intelligent inflation by fuzzy logic) |
| Sleeve | Preformed 360° Intelli Wrap, arm circumference 22-42 cm, with placement guide; materials nylon and polyester |
| Atrial fibrillation detection (AFib) | Yes, with each measurement |
| Pressure range | 0 mmHg to 299 mmHg ± 3 mmHg |
| Pulse range | 40 to 180 beats/min ± 5% of the reading |
| Inflation / Deflation | Electric pump controlled by fuzzy logic / Automatic pressure release valve |
| Memory | 100 × 2 users, with date and time (+ guest mode) |
| Average function | Average of the last 3 measurements taken within 10 minutes |
| Comparison of measurements | Yes, against previous readings |
| Positioning sensor | Yes (advanced) |
| Body movement detection | Yes |
| Cuff placement guide | Yes |
| Hypertension indicator | Yes (alert if values exceed E.H.S. standards for home self-measurement: systolic 135 and/or diastolic 85) |
| Connectivity | Bluetooth + OMRON Connect app |
| Power supply | 4 AA batteries, 1.5 V (6 V DC, 4 W); approximately 1,000 measurements |
| Protection against electric shock | Internally powered ME equipment (with batteries) |
| Weight (console + cuff, without batteries) | 460 + 163 g |
| Size | 191 × 120 × 85 mm |
| Clinical validation | Yes (check validations on the manufacturer’s website) |
4. Equivalences and Cross-References
Omron Healthcare does not publish an official cross-reference table authorising the direct replacement of the M7 Intelli IT AFib with models from other brands. The following cross-references have been checked against technical data sheets and official catalogues of the respective manufacturers and must be verified field by field (cuff, memory, connectivity, arrhythmia detection and clinical validation) before any substitution in tenders.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level |
|---|---|---|---|
| Omron | M4 Connect AFib | HEM-7155T-EBK | Comparable by category (not interchangeable 1:1): same AFib family with Bluetooth and OMRON Connect app; differs in memory (2×60 vs 2×100) and without TruRead function. |
| Omron | M6 Comfort AFib | HEM-7380-E | Comparable by category (not interchangeable 1:1): same technical base with AFib on each measurement and 2×100 memory, but without Bluetooth connectivity. |
| Omron | M3 Comfort AFib | HEM-7196-FLE | Comparable by category (not interchangeable 1:1): same AFib screening with Intelli Wrap cuff 22-42 cm; 2×60 memory and without Bluetooth. |
| Beurer | BM 64 | 65400 | Comparable by category (not interchangeable 1:1): advanced arrhythmia detection with triple measurement and 22-42 cm cuff; Beurer’s own validation algorithm. |
| Microlife | BP B3 AFIB | BP B3 AFIB | Comparable by category (not interchangeable 1:1): AFIBsens technology with conical cuff 22-42 cm; without Bluetooth or multi-user mode. |
There is no equivalence table validated by the manufacturer that cross-references the HEM-7380T1-EBK with other brands; consult the technical department of Cahnos before using this reference in tender documents or competitions.
5. Selection tips and variants of interest
Recommended profile: hypertensive patients, people with a history of cardiovascular disease or over 65 years of age who wish to carry out home screening for atrial fibrillation with digital recording of readings, as well as pharmacies, orthopaedic shops and home care services that need to document patient progress.
Check the cuff size: the included Intelli Wrap covers arms from 22 to 42 cm, the most common range in adults. An inappropriate cuff overestimates or underestimates readings.
Variants within Omron: if connectivity and AFib detection are not required, the M3 Comfort (HEM-7155-E) offers an Intelli Wrap cuff 22-42 cm and memory 2×60. For AFib screening without Bluetooth, the M6 Comfort AFib (HEM-7380-E) maintains memory 2×100 and triple average. If electrocardiographic recording is also needed, the Omron Complete (HEM-7530T-E3) combines blood pressure and 1-lead ECG with possible AFib analysis.
Reliable usage protocol: sit with your back supported and feet on the floor, place the cuff at heart level and do not talk or move during the measurement; the device warns if it detects movement or incorrect cuff fit. If a possible AFib warning appears, repeat the measurement and consult your doctor.
For institutional orders, tenders and purchasing centres, contact the technical-commercial department of Cahnos: we have the official technical data sheet, the manufacturer’s manual and the conformity documentation to validate the reference HEM-7380T1-EBK in specifications and tenders.











Reviews
There are no reviews yet.