Description
1. Commercial Introduction
Keep your sphygmomanometer always operational with the original replacement cuff for obese patients (Ref. 32849). This is the spare part recommended by the manufacturer to obtain reliable blood pressure measurements on large adult arms, a segment where a standard size distorts readings. Its construction in nylon, completely latex-free, with internal TPU bladder and PVC tubes, ensures uniform inflation and clinically reliable sealing performance for clinics, health centres, pharmacies and emergency services.
2. Technical explanation of the component
The cuff is the component of the blood pressure monitor that wraps around the patient’s arm to measure blood pressure non-invasively. When inflated, the internal bladder temporarily occludes the brachial artery and, when pressure is released in a controlled manner, allows detection of Korotkoff sounds (auscultatory method) or oscillations of the arterial wall (oscillometric method). For the measurement to be reliable, the bladder should cover approximately 40% of the arm circumference and the cuff must fit snugly, without folds or slack. This model incorporates a thermoplastic polyurethane (TPU) bladder that distributes pressure evenly and two independent PVC tubes for equipment connection: one carries the inflated air from the bulb to the bladder and the other transmits pressure to the manometer. Its 2-tube configuration makes it compatible with the dual-connection aneroid sphygmomanometers in the range.
3. Technical Specifications
Original manufacturer replacement cuff, calibrated, according to data verified in the manufacturer’s catalogue (Product_DB.csv).
| Characteristic | Specification |
|---|---|
| Product | Cuff for obese patients with bladder and 2 tubes |
| Material | Nylon, latex-free (latex free) |
| Chamber | TPU (thermoplastic polyurethane) |
| Tubing | PVC |
| Tube configuration | 2 tubes |
| Colour | Blue (Blue) |
| Model / size | Adult large |
| Cuff measurements | 62 x 17.5 cm (62×17.5) |
| Arm circumference | 34 – 51 cm |
| Calibration | Calibrated (calibrated) |
| Compatibility | Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton… |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| 32849 | Cuff for obese patients with bladder and 2 tubes, blue nylon, 62×17.5 cm, arm 34-51 cm (SKU Cahnos GM32849, this item) | 1 pc |
Product data
| Value | Value |
|---|---|
| Manufacturer | GIMA |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | I |
| CND | C99 |
| GMDN | 34978 |
| EAN | 8023279328493 |
4. Equivalences and Cross-References
This cuff corresponds to factory reference Ref. 32849 (SKU Cahnos GM32849), verified in the manufacturer’s catalogue. It is the 2-tube replacement in size for obese patients recommended by the manufacturer for the dual-connection aneroid sphygmomanometers of the Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire and Dayton families.
No equivalency table validated by the manufacturer has been found in reliable sources that declares this cuff as interchangeable 1:1 with cuffs from other blood pressure monitor brands: each manufacturer uses its own connectors, tube lengths and connection sizes. Any substitution between brands must be confirmed in advance with the technical-commercial department of Cahnos, verifying the 2-tube connection system, the connector diameter and the size of the specific device.
Within the same cuff family, the following related references with the same 2-tube configuration are identified:
| Reference | Description | Related items |
|---|---|---|
| GM32835 (Ref. 32835) | Premium cuff for obese patients, 2 tubes, 63×17.5 cm, arm 34.3 – 50.8 cm | Premium variant of the same size |
| GM32915 (Ref. 32915) | Adult large cuff, 2 tubes, 16×63 cm, arm 34.3 – 51 cm | One-piece size variant |
| GM32832 (Ref. 32832) | Premium adult cuff, 2 tubes, 54×15 cm, arm 25.4 – 40.6 cm | Standard size variant |
| GM32914 (Ref. 32914) | Adult one-piece cuff, 2 tubes, 14.5×54 cm, arm 26 – 41 cm | Construction and size variant |
| GM49707 (Ref. 49707) | Spare TPU bladder with 2 tubes, adult size, box of 5 units | Replacement for the internal bladder |
5. Selection tips and variants of interest
Select the size according to the actual circumference of the patient’s arm (measured at the midpoint between the shoulder and elbow): this cuff covers 34 to 51 cm and is the appropriate choice for large adult arms. A cuff that is too small causes overestimated readings and one that is too loose underestimates them, so the correct size is decisive in clinical practice.
Check compatibility: this model is 2-tube and designed for dual-connection aneroid sphygmomanometers (Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton). If your blood pressure monitor is single-tube (for example, Sirio, London, Boston, Roma 1T, Tokyo, Madrid, Ri-san, Precisa or Minimus) or from another manufacturer, it is not interchangeable without prior technical verification.
Periodically inspect the condition of the Velcro, the TPU bladder and the connection connectors; replace the cuff at signs of wear, air leaks or loss of adhesion to maintain measurement reliability. For large orders you can request a quote: consult our technical-commercial department of Cahnos for conditions, availability and delivery times.







Reviews
There are no reviews yet.