Description
1. Commercial Introduction
The premium cuff with TPU bladder and 1 tube (ref. 32830) is the original high-resistance replacement for single-connection aneroid sphygmomanometers. Its construction in high-quality 210D nylon, with an internal thermoplastic polyurethane (TPU) bladder and Velcro closure, offers a robust, hygienic and durable solution for medical practices, primary care, emergency services, nursing units and home care. As a factory-made part, the cuff retains the fit, comfort and inflation behaviour required by the original equipment, ensuring continuity of care for your fleet of blood pressure monitors.
2. Technical explanation
The cuff (armband) is the component of the sphygmomanometer that wraps around the arm and, when inflated, temporarily occludes the brachial artery to allow measurement of systolic and diastolic blood pressure. Its internal bladder must distribute pressure evenly and maintain airtightness so that the device correctly detects oscillations of the arterial wall and calculates reliable values.
This model from the Premium range incorporates a TPU bladder (blister) that distributes pressure evenly over the limb, and the assembly has passed durability tests of up to 10,000 cycles. Its configuration of 1 tube makes it compatible with single-connection aneroid sphygmomanometers from the Sirio, London, Boston, Roma 1T, Tokyo, Madrid, Ri-san, Precisa and Minimus families. An inappropriate size or a deteriorated cuff distorts pressure values; therefore, replacing the cuff with the original replacement of the correct size is essential for measurement accuracy.
3. Technical Specifications
| Characteristic | Detail |
|---|---|
| Product | Premium cuff with TPU bladder and 1 tube |
| Material | High-quality 210D nylon |
| Bladder (blister) | TPU (thermoplastic polyurethane) |
| Closure | Velcro |
| Colour | Dark grey (dark grey). Other colours available: royal blue, teal (teal), ceil blue and pink |
| Model / size | Adult |
| Cuff measurements | 54 x 15 cm |
| Arm circumference | 25.4 – 40.6 cm |
| Tube configuration | 1 tube |
| Durability | Tested up to 10,000 cycles |
| Compatibility | Sirio, London, Boston, Roma 1T, Tokyo, Madrid, Ri-san, Precisa, Minimus… |
Available references
| Reference | Colour | Sales unit |
|---|---|---|
| GM32830 | Dark grey (dark grey) | 1 pc |
| GM49750 | Royal blue (royal blue) | 1 pc |
| GM49751 | Teal (teal) | 1 pc |
| GM49752 | Ceil blue (ceil blue) | 1 pc |
| GM49753 | Pink | 1 pc |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 32830 (also 49750, 49751, 49752, 49753 depending on colour) |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | C99 |
4. Equivalences and Cross-References
This cuff corresponds to the factory reference Ref. 32830 (SKU Cahnos GM32830), verified in the manufacturer’s catalogue. It is the 1 tube replacement in adult size indicated by the manufacturer for single-connection aneroid sphygmomanometers from the Sirio, London, Boston, Roma 1T, Tokyo, Madrid, Ri-san, Precisa and Minimus families.
No equivalence table validated by the manufacturer has been found in reliable sources declaring this cuff as interchangeable 1:1 with cuffs from other blood pressure monitor brands. Cuffs from other manufacturers use their own connectors, tube lengths and connection sizes, so any replacement must be confirmed in advance with the technical-commercial department of Cahnos, verifying the connection system (1 tube), the connector diameter and the size of the specific device.
Within the range itself, the following related references from the same Premium line are identified:
| Reference | Description | Related items |
|---|---|---|
| GM32832 (Ref. 32832) | Premium cuff with TPU bladder, 2 tubes, 210D nylon, adult, 54×15 cm | Connection variant (2 tubes) of the same Premium line |
| GM32835 (Ref. 32835) | Premium cuff with TPU bladder, 2 tubes, adult large, 63×17.5 cm | Size variant of the same Premium line |
| GM49707 (Ref. 49707) | Spare TPU bladder with 2 tubes, adult size, box of 5 units | Replacement for the internal bladder |
5. Selection tips and variants of interest
Select the size according to the actual arm circumference (measured at the midpoint between the shoulder and the elbow): this adult cuff covers from 25.4 to 40.6 cm. A cuff that is too small causes overestimated readings and one that is too loose underestimates them, so choosing the correct size is decisive in clinical practice.
Check compatibility: this model is 1 tube and is designed for single-connection aneroid sphygmomanometers (Sirio, London, Boston, Roma 1T, Tokyo, Madrid, Ri-san, Precisa, Minimus). If your blood pressure monitor is dual-tube (Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton), you should opt for the 2-tube configuration (ref. GM32832).
The Premium range is available in several colours (dark grey, royal blue, teal, ceil blue and pink), which facilitates identification by service or professional in shared-use environments. For arms with a large circumference (34.3 – 50.8 cm), it offers the adult large size from the same premium line in 2 tubes (ref. GM32835), and for the internal bladder there is the TPU replacement (ref. GM49707).
Maintenance: periodically inspect the condition of the Velcro, the TPU bladder and the connection connector; replace the cuff if there are signs of wear, air leaks or loss of adhesion to maintain the reliability of measurements. For large orders you can request a quote: consult our technical-commercial department at Cahnos for terms and availability.