Description
1. Commercial Introduction
Maintain the accuracy of blood pressure readings in patients with large arm circumferences with this nylon cuff for obese patients, an original replacement of Italian manufacture (Ref. 32849). Made of durable nylon, completely latex-free, with a TPU bladder and PVC tubes, it is the double-tube spare part designed for dual-connection aneroid sphygmomanometers such as Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire and Dayton. A reliable, durable and correctly sized solution for practices, hospitals, primary care and medical equipment maintenance services.
2. Technical explanation of the component
The cuff is the component of the sphygmomanometer that surrounds the patient’s arm to measure blood pressure non-invasively. When inflated, the internal bladder temporarily occludes the brachial artery and, when pressure is released in a controlled manner, allows detection of Korotkoff sounds (auscultatory method) or oscillations of the arterial wall (oscillometric method). For the measurement to be reliable, the bladder should cover approximately 40% of the arm circumference and the cuff must fit snugly, without folds or slack.
This model incorporates a thermoplastic polyurethane (TPU) bladder that distributes pressure evenly and two independent PVC tubes: one carries the air inflated from the bulb to the bladder and the other transmits the pressure to the gauge. In adult large size, with dimensions of 62 x 17.5 cm, it is indicated for arm circumferences of 34 to 51 cm, the recommended range for obese patients. Its 2-tube configuration makes it compatible with the dual-connection aneroid equipment indicated by the manufacturer.
3. Technical Specifications
Calibrated nylon cuff for obese patients, latex-free, with TPU bladder and PVC tubes, in a 2-tube configuration. Data verified in the manufacturer’s official catalogue.
| Product | Cuff for obese patient with bladder, 2 tubes |
| Model / size | Adult large |
| Colour | Blue (nylon) |
| Measurements | 62 x 17.5 cm |
| Arm circumference | 34 – 51 cm |
| Cuff material | Nylon, latex-free (latex free) |
| Internal bladder | TPU (thermoplastic polyurethane) |
| Tubing | PVC, 2 tubes |
| Closure | Velcro |
| Calibrated | Yes |
| Compatible with | Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton… |
| Sales unit | 1 piece |
4. Equivalences and Cross-References
This cuff corresponds to factory reference 32849 (SKU Cahnos BRL32849), verified in the manufacturer’s official catalogue. It is the 2-tube replacement in the size for obese patients indicated by the manufacturer for the dual-connection aneroid sphygmomanometers of the Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire and Dayton family.
There is no equivalence table validated by the manufacturer declaring this cuff interchangeable 1:1 with cuffs from other blood pressure monitor brands: each manufacturer uses its own connectors, fitting diameters, tube lengths and bladder dimensions. Any substitution between brands must be confirmed beforehand with our technical-commercial department, verifying the 2-tube connection system, the fitting diameter and the size of the specific equipment. On the market there are large-arm cuffs for obese patients in the lines of brands such as Riester, Spengler, KaWe or ABN, but without a documented official reference cross-reference: consult the technical department before use in tenders.
Within the same family and 2-tube configuration, the catalogue offers related variants: the black nylon version in the identical size (Ref. 32841), the premium 2-tube version in dark grey (Ref. 32835, 63 x 17.5 cm), the one-piece adult large 2-tube cuff (Ref. 32915, 16 x 63 cm) and the TPU replacement bladder in adult size with 2 tubes (Ref. 49707).
5. Selection tips and variants of interest
Check that the patient’s arm circumference falls within the range of 34 to 51 cm: an inappropriate cuff distorts blood pressure measurements (a small cuff overestimates readings and a loose one underestimates them).
Verify that your blood pressure monitor or monitor uses a 2-tube connection; this model is designed for equipment such as Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire and Dayton. If your equipment is single-tube, consider the 1-tube version in the same size (Ref. 32848), designed for single-connection equipment.
Periodically check the condition of the TPU bladder, the tubes and the Velcro closure: replace it in the event of leaks, deformation or wear to preserve the accuracy of readings. If you manage a fleet of blood pressure monitors, keep this spare part in stock together with the rest of the sphygmomanometry family available in the Cahnos catalogue. For large orders you can request a quote: request a quotation from our technical-commercial team, who will advise you on supply conditions and volumes.