Description
1. Commercial Introduction
The adult cuff with bladder and 1-tube connection is the ideal original replacement to keep the single-connection aneroid sphygmomanometers of the manufacturer’s range operational. Made of calibrated nylon, completely latex-free and with an internal thermoplastic polyurethane (TPU) bladder and PVC tube, this cuff offers uniform inflation, a reliable seal and accurate blood pressure readings in daily clinical practice. A robust, hygienic and durable solution for medical practices, primary care, hospitals, pharmacies and emergency services, as well as for measurement equipment maintenance services.
2. Technical explanation
The cuff is the component of the blood pressure monitor that surrounds the patient’s arm and, when inflated, temporarily occludes the brachial artery to allow measurement of systolic and diastolic blood pressure, both by auscultatory method (Korotkoff sounds) and in equipment that detects oscillations of the arterial wall. Its internal bladder must distribute pressure evenly and maintain airtightness to ensure reliable values: an inappropriate size or a deteriorated cuff distorts the measurements.
This model incorporates a single-tube TPU bladder, with a single PVC conduit that connects the inflation bulb and the manometer of the device. It is a calibrated, latex-free cuff designed for single-connection aneroid sphygmomanometers of the Sirio, London, Boston, Roma 1T, Tokyo, Madrid, Ri-san, Precisa and Minimus families.
3. Technical Specifications
Calibrated nylon cuff, latex-free, with TPU bladder and PVC tube in 1-tube configuration, adult size. Data verified in the manufacturer’s catalogue.
| Characteristic | Detail |
|---|---|
| Product | Adult cuff with bladder and 1 tube |
| Cuff material | Nylon, latex-free (latex free) |
| Bladder | TPU (thermoplastic polyurethane) |
| Tubing | PVC |
| Tube configuration | 1 tube |
| Calibration | Calibrated |
| Colour | Blue / Red / Black |
| Model / size | Adult (Adult) |
| Size cm | 49 x 15 |
| Arm circumference | 26 – 40 cm |
| Compatibility | Sirio, London, Boston, Roma 1T, Tokyo, Madrid, Ri-san, Precisa, Minimus… |
Available references
| Reference | Colour | Sales unit |
|---|---|---|
| GM32842 | blue nylon | 1 pc |
| GM32844 | red nylon | 1 pc |
| GM32845 | black nylon | 1 pc |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device (medical device) |
| Device class | I |
| CND | C99 |
| GMDN | 34978 |
4. Equivalences and Cross-References
This cuff corresponds to factory references 32842 (blue nylon), 32844 (red nylon) and 32845 (black nylon), verified in the manufacturer’s catalogue. It is the 1-tube replacement in adult size indicated by the manufacturer for single-connection aneroid sphygmomanometers of the Sirio, London, Boston, Roma 1T, Tokyo, Madrid, Ri-san, Precisa and Minimus families.
No validated equivalence table from the manufacturer has been found in reliable sources that declares this cuff as 1:1 interchangeable with cuffs from other blood pressure monitor brands: each manufacturer uses its own connectors, tube lengths and connection sizes. Any substitution between brands must be confirmed beforehand with the technical-commercial department of Cahnos, verifying the 1-tube connection system, the connector diameter and the size of the specific device.
Within the 1-tube cuff family itself, the following related references are identified: the 2-tube version of the same size and fit (Refs. GM32843 blue and GM32850 black, also 49×15 cm and 26-40 cm), the premium cuff with 1-tube TPU bladder in adult size (Ref. GM32830, 54×15 cm), the 1-tube cuff for obese patients (Ref. GM32848, 62×17.5 cm) and the 1-tube TPU replacement bladder for adults (Ref. GM49706), as well as the range of one-piece cuffs with integrated bladder (Refs. GM32910 to GM32915).
5. Selection tips and variants of interest
Select the size according to the actual circumference of the patient’s arm (measured at the midpoint between the shoulder and the elbow): this adult cuff covers 26 to 40 cm. A cuff that is too small causes overestimated readings and one that is too loose underestimates them, so the correct size is decisive in clinical practice.
Check compatibility: this model is 1-tube and is designed for single-connection aneroid sphygmomanometers (Sirio, London, Boston, Roma 1T, Tokyo, Madrid, Ri-san, Precisa, Minimus). If your blood pressure monitor is dual-tube (Minor, Yton line, Roma 2T, Dallas, Big Ben, Empire, Dayton), you must choose the 2-tube configuration (Refs. GM32843 / GM32850).
Choose the reference by colour according to your needs: blue nylon (Ref. GM32842), red nylon (Ref. GM32844) or black nylon (Ref. GM32845), which facilitates identification by service or professional in shared-use environments. Periodically inspect the condition of the TPU bladder, the PVC tube and the closure; replace the cuff at signs of wear, air leaks or loss of airtightness to maintain the reliability of measurements. For large orders you can request a quote: consult our technical-commercial department of Cahnos for conditions, availability and delivery times.








Reviews