Description
1. Commercial Introduction
The sterile 28G lancets (ref. 23916) are the reference consumable for self-monitoring of blood glucose and daily work in clinics, health centres, pharmacies and laboratories that perform capillary puncture. Their fine needle allows the required blood drop to be obtained with a quick, controlled puncture and minimal discomfort, making them a very well-tolerated option even in patients with frequent punctures or sensitive skin. Compatible with the lancing device (ref. 23919) and with most devices on the market, they simplify stock management and unify the sample collection routine at the point of care.
2. Technical explanation
Capillary puncture is the standard method for obtaining small amounts of blood for glucose meters, test strips and point-of-care analysers (POCT). These lancets are loaded into a puncture device or lancing device: the sterility protection is removed, the lancet is inserted into the device and, via the trigger mechanism, the fine 28G needle makes a superficial, controlled incision in the fingertip, facilitating the formation of the required blood drop. They have been expressly indicated by the manufacturer for use with code 23919 and with most lancing devices on the market. Each unit is sterile and single-use, avoiding the risk of cross-contamination between patients; the box and instructions are multilingual and include Spanish.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 23916 |
| SKU Cahnos | GM23916 |
| Needle gauge | 28G (fine needle) |
| Sales unit | Box of 100 units |
| Device type | Medical device (Medical device) |
| Device class | II A |
| CND | V010402 |
| EAN | 8023279239164 |
| Condition of use | Sterile, single-use, disposable |
| Intended use | Capillary puncture for blood glucose monitoring and point-of-care testing |
| Compatibility | Lancing device Ref. 23919 and most lancing devices on the market |
| Languages of the box and instructions | Multilingual (GB, FR, IT, ES, PT, DE, PL, CZ, SE, RO, SK, NL, DK, FI, EE, HR, HU, LT, LV, NO, SI, BG, GR and Arabic) |
Available references
| Reference | Description | Presentation |
|---|---|---|
| 23916 (GM23916) | Sterile 28G lancets for lancing device (this product) | Box of 100 units |
| 23919 (GM23919) | Lancing device / compatible puncture device, adjustable tip with 10 depth settings | Unit |
4. Equivalences and Cross-References
There is no 1:1 equivalence table validated by the manufacturer that relates reference 23916 to exact codes from other brands. This is a universal-design lancet for capillary puncture devices, so within the Cahnos catalogue the following references are identified as comparable by function and use (not interchangeable without technical validation):
- GM23921 (ref. 23921): sterile 32G lancets for lancing device 23919, same range and purpose with a finer gauge.
- GM23919 (ref. 23919): reusable automatic lancing device, associated puncture device.
- 1110104 / 0658015-1: plastic blood lancet 23G of universal design for puncture devices.
- SLN2816: 28G safety lancet with 1.6 mm blade, comparable by category (single-dose format with safety mechanism, not interchangeable with lancing device).
- GM24455 and GM24465: automatic safety lancets 28G (round and square), comparable by category in capillary puncture.
For any substitution or use in technical specifications with a closed specification, consult the technical department of Cahnos to validate gauge, depth and compatibility.
5. Selection tips and variants of interest
Choose these 28G lancets when you need a reliable and economical replacement format for lancing devices commonly used in blood glucose monitoring. Their fine gauge provides a good balance between sample volume and comfort, being suitable for frequent punctures and sensitive skin. For an even finer gauge and minimal discomfort, consider the 32G variant (ref. 23921). To complete your puncture system, combine this consumable with the automatic lancing device (ref. 23919, SKU GM23919). If your centre prioritises the prevention of accidental needlestick injuries and works in single-dose format, consider the automatic safety lancets in the range (refs. GM24455, GM24465) or the safety lancets from other manufacturers in the catalogue. Remember that they are single-use devices: dispose of them in a sharps container in accordance with current healthcare waste regulations and always follow the manufacturer’s instructions for use. For large orders you can request a quote: contact our technical-commercial team for terms and volumes.