Description
1. RIESTER RVS-100 multiparameter monitor – 1960-RRBPE
The RIESTER RVS-100 multiparameter monitor is the bedside solution designed by the German manufacturer Rudolf Riester for fast and reliable vital signs monitoring in demanding healthcare environments. This 1960-RRBPE configuration incorporates non-invasive blood pressure (NIBP), pulse oximetry (SpO2), predictive thermometer (Filac 3000) and integrated printer, making it a complete monitoring station for emergency departments, triage, consultations, examination rooms and hospital wards. Its 8″ colour TFT touchscreen with intuitive interface and integrated help function allows easy operation and immediate reading of parameters. Distributed in the healthcare channel under reference 33801, it is sold individually. For large orders, you can request a quote.
2. Technical description of the equipment
The RVS-100 combines the main non-invasive measurement techniques in a single device. Blood pressure is determined by the automatic oscillometric method of clinical quality, with adult, paediatric and neonatal modes, averaging function (2-5 readings) and dual overpressure protection (hardware and software). Pulse oximetry uses Riester Oximax technology to measure oxygen saturation (SpO2) and pulse rate with configurable averaging times (4, 8 or 16 s). Temperature is obtained via the oral predictive thermometer with results in 3-10 seconds. The device offers 3 measurement modes (Monitor, Spot-check and Triage), programmable early warning scores EWS/NEWS/MEWS, 3-level visual and acoustic alarms in accordance with IEC 60601-1-8, internal memory for 5,000 measurements, LAN connectivity (HL7) for integration with the electronic health record, 4 USB ports, RJ11 nurse call output and a lithium-ion battery with up to 11 hours of autonomy.
3. Technical specifications and tables
Product data
| Brand | Riester |
|---|---|
| Manufacturer’s reference (Riester) | 1960-RRBPE |
| Reference | 33801 |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | Z1203020201 |
Non-invasive blood pressure monitoring (NIBP)
| Parameter | Adult | Paediatric | Neonatal |
|---|---|---|---|
| Systolic pressure (SYS) | 30-270 mmHg | 30-235 mmHg | 30-135 mmHg |
| Diastolic pressure (DIA) | 10-220 mmHg | 10-220 mmHg | 10-110 mmHg |
| Mean arterial pressure (MAP) | 20-235 mmHg | 20-225 mmHg | 20-125 mmHg |
| Specification | Value |
|---|---|
| Measurement method | Automatic oscillometric |
| Cuff pressure range | 0-280 mmHg (resolution 1 mmHg) |
| Pressure accuracy | Static ±3 mmHg; clinical ±5 mmHg (standard deviation 8 mmHg) |
| Pulse rate range | 40-240 bpm (accuracy 1 bpm) |
| Initial inflation pressure | Adult 160 mmHg / Paediatric 130 mmHg / Neonatal 75 mmHg |
| Overpressure protection | Dual (hardware and software): Adult 297±3 mmHg / Paediatric 252±3 mmHg / Neonatal 147±3 mmHg |
| Alarm range | SYS, DIA, MAP: 0-300 mmHg |
Pulse oximetry (SpO2) and pulse rate
| Parameter | Value |
|---|---|
| SpO2 measurement range | 0-100 % (resolution 1 %) |
| SpO2 accuracy | ±2 % (70-100 %); ±3 % (40-69 %); not specified (0-39 %) |
| SpO2 alarm range | 0-100 % |
| Averaging time | 4 s, 8 s, 16 s |
| Pulse rate range | 20-250 bpm (resolution 1 bpm) |
| Pulse rate accuracy | ±1 % or ±1 bpm (whichever is greater) |
Predictive thermometer (Filac 3000)
| Parameter | Value |
|---|---|
| Oral fast mode (without fever) | 3-5 seconds |
| Oral fast mode (with fever) | 8-10 seconds |
| Oral standard mode | 6-10 seconds |
| Accuracy | 35.5-42 °C ± 0.1 °C (± 0.2 °F) |
Monitor, connectivity and power supply
| Specification | Value |
|---|---|
| Display | 8″ colour TFT touchscreen, high sensitivity, integrated help function |
| Displayed parameters | SYS, DIA, MAP, pulse, temperature, plethysmogram |
| Early warning scores | EWS, NEWS, MEWS and 5 customisable profiles |
| Alarms | Visible LEDs (red, yellow, cyan), audible speaker, QRS tone; in accordance with IEC 60601-1-8 (45-85 dB at 1 m) |
| Ports | 1 AC input, 1 RJ45 (100 BASE-TX, IEEE 802.3), 4 USB, 1 equipotential earth terminal, 1 RJ11 nurse call, DC output 15 V/1.2 A |
| Connectivity | LAN as standard, HL7 (EMR) standard, Bluetooth with Riester tymPRO and sensioPRO thermometers |
| Power supply | 100-240 V AC, 50/60 Hz |
| Battery | Rechargeable lithium-ion 10.8 V DC, 6,600 mAh; full charge in 6 h; approx. 11 h autonomy (automatic mode, 15 min intervals) |
| Memory | Internal for 5,000 measurements |
| Dimensions | 303 x 110 x 230 mm |
| Weight | 3,600 g (includes temperature module and printer) |
Included accessories
| Accessory | Detail |
|---|---|
| Adult SpO2 sensor | Included |
| SpO2 extension cable | Included |
| Oral temperature catheter | Included, with spare covers |
| NIBP extension tube | Included |
| NIBP cuffs | 2 cuffs with connector (adult and large adult) |
| User manual | GB, IT (FR, DE, ES, RU on request) |
4. Equivalences and Cross-References
Available references:
| SKU Cahnos | Reference | Riester reference | Description |
|---|---|---|---|
| GM33801 | 33801 | 1960-RRBPE | RVS-100 multiparameter monitor: NIBP + SpO2 + predictive temperature + printer (this product) |
| GM33800 | 33800 | 1960-RRXPE | RVS-100 multiparameter monitor: NIBP + SpO2 + printer (variant without thermometer) |
No direct equivalent reference from other manufacturers has been confirmed for the Riester RVS-100 monitor (connectors and protocols are specific to each manufacturer). As comparable references by category within the Cahnos vital signs monitor catalogue, the multiparameter monitor PC-3000 (GM35134) and the UP 7000 (GM35145) can be consulted, as well as the handheld monitor PC-300 (GM35162) for spot-check measurement. To equip the complete monitoring station with original accessories from the same RVS-100 family, Cahnos offers the paediatric SpO2 sensor (GM33805, ref. 13301), the replacement adult SpO2 sensor (GM33806, ref. 13302), the trolley with basket (GM33810, ref. 13317) and the paediatric Velcro cuff 35.5 x 10 cm (GM33813, ref. 129,006).
5. Selection tips and variants of interest
The 1960-RRBPE (GM33801) variant is the most complete configuration in the RVS-100 range as it adds the oral predictive thermometer with results in seconds; if you already have a separate thermometer or do not require integrated temperature measurement, the 1960-RRXPE version (GM33800, NIBP + SpO2 + printer) covers the essential parameters. Select the cuff size according to arm circumference: the device is supplied with adult and large adult cuffs, and supports the optional paediatric Velcro cuff (ref. 129,006) and the adult and paediatric SpO2 sensors from the same family. The triage mode with EWS/NEWS/MEWS scales makes it especially suitable for emergency departments and triage bays, while LAN connectivity (HL7) and the 5,000-measurement memory facilitate its integration into the centre’s electronic health record. For institutional orders, tenders or purchasing groups, contact the technical-commercial department of Cahnos.