We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

RIESTER RVS-100 multiparameter vital signs monitor (1960-RRBPE) – NIBP, SpO2, predictive temperature and printer | Ref. 33801

3.914,00 €

The RIESTER RVS-100 multiparameter monitor (1960-RRBPE) is a bedside device with an 8″ colour TFT touchscreen that integrates clinical-quality non-invasive blood pressure (NIBP), Oximax SpO2 pulse oximetry, predictive thermometer (Filac 3000), printer and history of up to 5,000 measurements. With 3 usage modes (monitoring, spot-check and triage) and early warning scores EWS, NEWS and MEWS for neonatal, paediatric and adult patients. Original Riester reference 1960-RRBPE (Ref. 33801). For large orders, you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33801

Description

1. RIESTER RVS-100 multiparameter monitor – 1960-RRBPE

The RIESTER RVS-100 multiparameter monitor is the bedside solution designed by the German manufacturer Rudolf Riester for fast and reliable vital signs monitoring in demanding healthcare environments. This 1960-RRBPE configuration incorporates non-invasive blood pressure (NIBP), pulse oximetry (SpO2), predictive thermometer (Filac 3000) and integrated printer, making it a complete monitoring station for emergency departments, triage, consultations, examination rooms and hospital wards. Its 8″ colour TFT touchscreen with intuitive interface and integrated help function allows easy operation and immediate reading of parameters. Distributed in the healthcare channel under reference 33801, it is sold individually. For large orders, you can request a quote.

2. Technical description of the equipment

The RVS-100 combines the main non-invasive measurement techniques in a single device. Blood pressure is determined by the automatic oscillometric method of clinical quality, with adult, paediatric and neonatal modes, averaging function (2-5 readings) and dual overpressure protection (hardware and software). Pulse oximetry uses Riester Oximax technology to measure oxygen saturation (SpO2) and pulse rate with configurable averaging times (4, 8 or 16 s). Temperature is obtained via the oral predictive thermometer with results in 3-10 seconds. The device offers 3 measurement modes (Monitor, Spot-check and Triage), programmable early warning scores EWS/NEWS/MEWS, 3-level visual and acoustic alarms in accordance with IEC 60601-1-8, internal memory for 5,000 measurements, LAN connectivity (HL7) for integration with the electronic health record, 4 USB ports, RJ11 nurse call output and a lithium-ion battery with up to 11 hours of autonomy.

3. Technical specifications and tables

Product data

Brand Riester
Manufacturer’s reference (Riester) 1960-RRBPE
Reference 33801
Sales unit 1 pc
Device type Medical device (Medical device)
Device class II B
CND Z1203020201

Non-invasive blood pressure monitoring (NIBP)

Parameter Adult Paediatric Neonatal
Systolic pressure (SYS) 30-270 mmHg 30-235 mmHg 30-135 mmHg
Diastolic pressure (DIA) 10-220 mmHg 10-220 mmHg 10-110 mmHg
Mean arterial pressure (MAP) 20-235 mmHg 20-225 mmHg 20-125 mmHg
Specification Value
Measurement method Automatic oscillometric
Cuff pressure range 0-280 mmHg (resolution 1 mmHg)
Pressure accuracy Static ±3 mmHg; clinical ±5 mmHg (standard deviation 8 mmHg)
Pulse rate range 40-240 bpm (accuracy 1 bpm)
Initial inflation pressure Adult 160 mmHg / Paediatric 130 mmHg / Neonatal 75 mmHg
Overpressure protection Dual (hardware and software): Adult 297±3 mmHg / Paediatric 252±3 mmHg / Neonatal 147±3 mmHg
Alarm range SYS, DIA, MAP: 0-300 mmHg

Pulse oximetry (SpO2) and pulse rate

Parameter Value
SpO2 measurement range 0-100 % (resolution 1 %)
SpO2 accuracy ±2 % (70-100 %); ±3 % (40-69 %); not specified (0-39 %)
SpO2 alarm range 0-100 %
Averaging time 4 s, 8 s, 16 s
Pulse rate range 20-250 bpm (resolution 1 bpm)
Pulse rate accuracy ±1 % or ±1 bpm (whichever is greater)

Predictive thermometer (Filac 3000)

Parameter Value
Oral fast mode (without fever) 3-5 seconds
Oral fast mode (with fever) 8-10 seconds
Oral standard mode 6-10 seconds
Accuracy 35.5-42 °C ± 0.1 °C (± 0.2 °F)

Monitor, connectivity and power supply

Specification Value
Display 8″ colour TFT touchscreen, high sensitivity, integrated help function
Displayed parameters SYS, DIA, MAP, pulse, temperature, plethysmogram
Early warning scores EWS, NEWS, MEWS and 5 customisable profiles
Alarms Visible LEDs (red, yellow, cyan), audible speaker, QRS tone; in accordance with IEC 60601-1-8 (45-85 dB at 1 m)
Ports 1 AC input, 1 RJ45 (100 BASE-TX, IEEE 802.3), 4 USB, 1 equipotential earth terminal, 1 RJ11 nurse call, DC output 15 V/1.2 A
Connectivity LAN as standard, HL7 (EMR) standard, Bluetooth with Riester tymPRO and sensioPRO thermometers
Power supply 100-240 V AC, 50/60 Hz
Battery Rechargeable lithium-ion 10.8 V DC, 6,600 mAh; full charge in 6 h; approx. 11 h autonomy (automatic mode, 15 min intervals)
Memory Internal for 5,000 measurements
Dimensions 303 x 110 x 230 mm
Weight 3,600 g (includes temperature module and printer)

Included accessories

Accessory Detail
Adult SpO2 sensor Included
SpO2 extension cable Included
Oral temperature catheter Included, with spare covers
NIBP extension tube Included
NIBP cuffs 2 cuffs with connector (adult and large adult)
User manual GB, IT (FR, DE, ES, RU on request)

4. Equivalences and Cross-References

Available references:

SKU Cahnos Reference Riester reference Description
GM33801 33801 1960-RRBPE RVS-100 multiparameter monitor: NIBP + SpO2 + predictive temperature + printer (this product)
GM33800 33800 1960-RRXPE RVS-100 multiparameter monitor: NIBP + SpO2 + printer (variant without thermometer)

No direct equivalent reference from other manufacturers has been confirmed for the Riester RVS-100 monitor (connectors and protocols are specific to each manufacturer). As comparable references by category within the Cahnos vital signs monitor catalogue, the multiparameter monitor PC-3000 (GM35134) and the UP 7000 (GM35145) can be consulted, as well as the handheld monitor PC-300 (GM35162) for spot-check measurement. To equip the complete monitoring station with original accessories from the same RVS-100 family, Cahnos offers the paediatric SpO2 sensor (GM33805, ref. 13301), the replacement adult SpO2 sensor (GM33806, ref. 13302), the trolley with basket (GM33810, ref. 13317) and the paediatric Velcro cuff 35.5 x 10 cm (GM33813, ref. 129,006).

5. Selection tips and variants of interest

The 1960-RRBPE (GM33801) variant is the most complete configuration in the RVS-100 range as it adds the oral predictive thermometer with results in seconds; if you already have a separate thermometer or do not require integrated temperature measurement, the 1960-RRXPE version (GM33800, NIBP + SpO2 + printer) covers the essential parameters. Select the cuff size according to arm circumference: the device is supplied with adult and large adult cuffs, and supports the optional paediatric Velcro cuff (ref. 129,006) and the adult and paediatric SpO2 sensors from the same family. The triage mode with EWS/NEWS/MEWS scales makes it especially suitable for emergency departments and triage bays, while LAN connectivity (HL7) and the 5,000-measurement memory facilitate its integration into the centre’s electronic health record. For institutional orders, tenders or purchasing groups, contact the technical-commercial department of Cahnos.

Additional information

Manufacturer reference

33801

Riester reference

1960-RRBPE

Device type

Medical device (Medical device)

CND code

Z1203020201

Parameters

NIBP, SpO2, predictive temperature, pulse rate

Display

8" colour TFT touchscreen, high sensitivity

Measurement modes

Monitor, Spot-check, Triage (adult, paediatric and neonatal)

Early warning scores

EWS, NEWS, MEWS (5 customisable profiles)

NIBP method

Automatic oscillometric of clinical quality with averaging (2-5 readings) and neonatal mode

Pressure range

SYS 30-270 mmHg; DIA 10-220 mmHg; MAP 20-235 mmHg (adult)

Overpressure protection

Dual protection (hardware and software)

SpO2 range

0-100 % (resolution 1 %)

Spo2 accuracy

±2 % (70-100 %); ±3 % (40-69 %)

SpO2 averaging time

4 s, 8 s, 16 s

Temperature

Oral predictive thermometer (Filac 3000); accuracy 35.5-42 °C ± 0.1 °C

Memory

Internal for 5,000 measurements

Connectivity

LAN (HL7), Bluetooth, 4 USB ports, RJ45, RJ11 nurse call

Power supply

100-240 V AC, 50/60 Hz

Battery

Rechargeable lithium-ion 10.8 V DC, 6,600 mAh; battery life approx. 11 h

Dimensions

303 x 110 x 230 mm

Weight

3,600 g

Printer

Integrated

Included accessories

Adult SpO2 sensor, SpO2 extension cable, oral catheter with covers, NIBP tube, 2 cuffs (adult and large adult), manual GB/IT

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityMultilingüe PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “RIESTER RVS-100 multiparameter vital signs monitor (1960-RRBPE) – NIBP, SpO2, predictive temperature and printer | Ref. 33801”

Your email address will not be published. Required fields are marked *