Description
1. PalmCare Pro handheld pulse oximeter: reliable SpO2 monitoring in any healthcare setting
The PalmCare Pro handheld pulse oximeter (ref. 40.50-2240) is a portable oxygen saturation and pulse rate monitor designed for professionals who need accurate, rapid, non-invasive readings: medical offices, primary care, emergency care, patient transport, hospitalisation and social-healthcare centres. Its 3″ colour TFT LCD screen provides clear display of all parameters, and its compact design of 154 x 72 x 26 mm and 273 g facilitates transport and one-handed operation. The device is supplied with a reusable adult SpO2 probe, 4 AA alkaline batteries, a protective case and user manual, and is backed by the 24-month warranty of Cahnos.
2. How it works and what it offers technically
Pulse oximetry is a non-invasive optical method that measures the functional oxygen saturation of arterial haemoglobin by differential absorption of red (660 nm) and infrared (905 nm) light through the capillary bed. The PalmCare Pro processes that signal and simultaneously displays the SpO2 value, pulse rate, pulse waveform (plethysmogram), alarm status and limits, perfusion index and battery status.
It incorporates perfusion index (PI), a parameter that quantifies the strength of pulsatile flow at the measurement point and allows assessment of signal quality, and 4 switchable screen modes. Its 20-day trend memory (at 10-second intervals) facilitates prolonged patient monitoring. The device supports adult, paediatric and neonatal patients simply by changing the type of SpO2 probe connected, making it a versatile solution for services with a mixed population.
3. Technical Specifications
General technical data sheet
| Reference (SKU) | 40.50-2240 |
| Model | PalmCare Pro (version with AA alkaline batteries included) |
| Set type | Handheld pulse oximeter for adults, children and babies |
| Display | 3″ colour TFT LCD (240 x 400 pixels) |
| Screen modes | 4 different switchable views |
| Age groups | Adults, paediatric and neonates |
| Perfusion index (PI) | Yes (range 0.05 % – 20 %) |
| Trend memory | 20 days at 10-second intervals |
| Alarms | Visual and acoustic, with adjustable limits (low SpO2, pulse rate, low battery, finger out) |
| Protection | IPX1 |
| Operating temperature | 5 °C – 35 °C |
Measurement accuracy
| Parameter | Specification |
| SpO2 range | 0 % – 100 % |
| SpO2 accuracy | ±2 digits between 70 % – 100 % (adults and paediatric); ±3 digits (neonates) |
| SpO2 resolution | 1 % |
| Pulse rate range | 30 – 250 ppm |
| Pulse rate accuracy | ±3 digits |
| Pulse rate resolution | 1 ppm |
| Sensor wavelengths | Red 660 nm / Infrared 905 nm |
Power supply, dimensions and contents
| Characteristic | Value |
| Alkaline batteries | 4 x AA (up to 10 hours battery life); included in this version |
| Rechargeable battery (compatible) | Lithium-ion (up to 8 hours; charging time approx. 6 hours) |
| Dimensions | 154 x 72 x 26 mm |
| Weight | Approx. 273 g |
| Included accessories | Adult reusable SpO2 catheter, 4 AA alkaline batteries, protective case and user manual |
| Optional accessories | Paediatric and neonate catheters (Y type), SoftTouch catheter, extension cable, forceps for infusion support |
4. Equivalences and Cross-References
The PalmCare Pro belongs to the category of handheld pulse oximeters with trend memory and perfusion index. There is no official equivalence table validated by the manufacturer that cross-references this code with specific codes from other brands; below are products that are comparable at category level (same clinical indication: monitoring of SpO2 and pulse in adult, paediatric and neonatal patients), with the warning that they are not interchangeable 1:1 and must be validated against each manufacturer’s technical data sheet before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Nonin Medical | PalmSAT 2500A (with alarms) | N-2500A (rechargeable base N-2500C-UNIV) | Comparable by category (not interchangeable 1:1) | Handheld monitor with alarms, 72-hour memory and PureSAT technology; red LED screen (without PI or colour display); powered by 4 AA batteries or base with rechargeable battery |
| Nonin Medical | Hand Held 8500 | N-8500 | Comparable by category (not interchangeable 1:1) | Version without alarms, very robust, up to 100 hours with AA batteries; without perfusion index or 20-day trend memory |
| Masimo | Rad-57 (pulse co-oximeter) | MA-9216 (distributor code) | Comparable by category (not interchangeable 1:1) | Includes perfusion index (PI) and SET technology for motion and low perfusion, but adds co-oximetry (SpCO and SpMet); aimed at emergency care, with more parameters and higher cost |
| Huntleigh | smartsigns MiniPulse | MP1 (rechargeable MP1R) | Comparable by category (not interchangeable 1:1) | Handheld pulse oximeter with large LED screen, 4 AA batteries and over 60 hours of use; includes pulsatility index display, without 20-day trend memory |
There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender or replacing the device with a model from another brand.
5. Selection tips and variants of interest
- Choose the probe according to the patient: the device is supplied with a reusable adult probe; for paediatrics and neonates the specific probe must be purchased (type Y for neonate, family 41.20-5264).
- No mains power required: with the 4 included AA batteries it has up to 10 hours of autonomy; the device also supports a rechargeable lithium-ion battery if you wish to upgrade the version.
- Mounting and placement: if you are going to mount the monitor on an infusion or bed stand, request the mounting clamp (ref. 41.50-2221) and the probe extension cable (ref. 41.50-2032) for greater versatility.
- Catalogue variants: the version with included rechargeable Li-Ion battery (ref. 40.50-2300) is the ideal alternative if your service requires continuous autonomy without depending on batteries. For occasional measurements at lower cost, the ME5 (40.22-5206), ME7 (40.21-5207) and ME10 (40.22-5205) finger pulse oximeter family are more economical options.
- Maintenance: clean the probe and device with appropriate wipes between patients, respect battery polarity and periodically check for visible damage that could compromise measurement safety.