Description
1. Introduction
The SpO2 finger clip (ref. 35153) is the manufacturer’s official replacement part to restore pulse oximetry on the pulse oximeters Ref. 35152 and 35213. Designed for adult patients or children over 40 kg, it is the perfect solution for diagnostic services, emergency departments, consultations and vital signs monitoring that need to replace the original catheter without replacing the complete equipment.
Being an original quality replacement, it guarantees connector compatibility with your pulse oximeter and signal reliability in every measurement. For large orders you can request a quote: contact our technical-commercial team for B2B conditions and availability.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin (SpO2) and pulse rate by spectrophotometry. This finger clip integrates the emitter and photodetector in a single clip-type body that attaches to the patient’s finger: the emitter projects red and infrared light through the vascular bed and the detector quantifies the differential absorption according to the degree of blood oxygenation, transmitting the signal to the pulse oximeter, which processes and displays the values in real time.
Its clip design allows quick, stable and ergonomic placement, facilitating occasional or continuous monitoring in adult patients and in children over 40 kg, both in consultation and in home care and hospitalisation.
3. Technical Specifications
This part is supplied as a replacement (spare) for the original catheter of the pulse oximeter Ref. 35152 or 35213. Always check the reference of your equipment before requesting the replacement.
Product data
| Field | Value |
|---|---|
| Manufacturer | GIMA |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | C900301 |
| EAN | 6945040105664 |
Technical features
| Parameter | Specification |
|---|---|
| Manufacturer reference | 35153 |
| Catheter type | SpO2 finger clip (finger probe) |
| Patient population | Adults or children over 40 kg |
| Compatibility | Pulse oximeters Ref. 35152 and 35213 |
| Use | Replacement (spare) |
| Measured parameters | Oxygen saturation (SpO2) and pulse rate |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| GM35153 | Adult SpO2 finger clip for pulse oximeters Ref. 35152 and 35213 – Replacement (ref. 35153) | 1 pc |
4. Equivalences and Cross-References
Reference 35153 is a manufacturer’s own catalogue code for this replacement SpO2 finger clip. The manufacturer uses proprietary connectors per equipment family, so we do not have a manufacturer-validated equivalence table that cross-references this catheter with codes from other brands on a 1:1 interchangeable basis. Before replacing any pulse oximeter catheter, always check the compatibility of the connector and communication protocol with the exact brand and model of your equipment.
Within the range itself, the catheters designed for the same pulse oximeters 35152 and 35213 are the reusable paediatric catheter ref. 35215 (10-40 kg) and the neonatal catheter ref. 35216 (3-10 kg). These variants are similar by category and population, but not interchangeable with each other without verifying the connector and equipment model.
5. Selection tips and variants of interest
- Check your monitor: this clip is indicated for the pulse oximeters Ref. 35152 and 35213. Always provide the full reference of your equipment to confirm compatibility before placing the order.
- Choose the correct population: for adults or children over 40 kg this is the indicated catheter. For paediatric patients of 10-40 kg you have ref. 35215 and for neonates of 3-10 kg ref. 35216.
- Maintenance: clean the clip between patients with a soft cloth or compatible disinfectant solution, without submerging it, and keep the cable free of sharp bends to extend its service life.
- Stock management: as this is an official replacement part, we recommend keeping one replacement unit per device to avoid interruptions in patient monitoring.
- B2B conditions: Contact our technical-commercial department at Cahnos for conditions, lead times and availability.