Description
1. Commercial Introduction
This 5-lead ECG cable is the original spare part for the vital signs monitors in the PC-3000, UP-7000 and VITAL lines. Designed as a spare part, it allows you to quickly replace the patient cable on your monitor and keep cardiac monitoring running without interruption. It is the ideal maintenance solution for hospitals, emergency departments, ICUs, dressing rooms, cardiology clinics and diagnostic centres that want to always have a spare cable for their equipment.
2. Technical explanation of the equipment
The ECG patient cable is the element in the recording chain that connects the electrodes placed on the patient’s chest to the input of the vital signs monitor or the electrocardiograph. This model has 5 leads, the standard configuration for capturing the main limb and precordial leads during continuous monitoring, and has a length of 3.75 m, offering the flexibility required in working environments with stretchers and trolleys.
As a reusable accessory subject to mechanical stress and continuous handling on every shift, having an original replacement guarantees the stability of the electrocardiographic signal, reduces the risk of artefacts and avoids equipment downtime.
3. Technical specifications and tables
Data verified against the manufacturer’s catalogue (.):
| Parameter | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 35137 |
| Product type | Patient cable for electrocardiography (ECG) – replacement |
| Number of leads | 5-lead |
| Length | 3.75 m |
| Compatibility | Vital signs monitors PC-3000, UP-7000 and VITAL |
| Sales unit | 1 pc (unit) |
| Device type | Medical device |
| Device class | I |
| CND | Z1203020280 |
| EAN | 8023279351378 |
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table available to cross-reference this reference 35137 with codes from other manufacturers. The stated compatibility applies exclusively to the monitors in the PC-3000, UP-7000 and VITAL lines: always check the number of leads, the connector type and the cable length of your equipment before replacing it. In the Cahnos catalogue you will find other patient cables in the same family, such as the ECG cable for the 33316 monitor (Ref. 33317), the universal 10-lead cable (Ref. 33328) or the 3-lead, 3-pin version cable for ECG Palmare (Ref. 33248); each one is designed for specific equipment and they are not interchangeable with one another without prior technical verification.
5. Selection tips and variants of interest
Before replacing the cable, confirm that your monitor belongs to the PC-3000, UP-7000 or VITAL lines and that the number of leads matches this reference (5 leads, 3.75 m). Periodically check the condition of the terminals, the integrity of the insulation and the connection area to the equipment, and clean the cable according to the manufacturer’s instructions for use to maintain a stable signal transmission. It is recommended to keep a spare cable per monitor so as not to interrupt monitoring during maintenance. For volume orders, fleets or tenders, contact the technical-commercial department of Cahnos to confirm exact compatibility and request a tailored quote.