Description
1. Introduction
The PalmCare Pro handheld pulse oximeter with rechargeable lithium-ion battery is the bedside tool for non-invasive monitoring of oxygen saturation (SpO2) and pulse rate in any care setting: clinics, primary care, emergency care, patient transport, hospitalisation and social healthcare centres. Its 3-inch colour TFT LCD screen provides a clear and detailed reading of patient parameters, and its dual power supply system (alkaline batteries or rechargeable battery) ensures continuity of monitoring even when mains power is not available.
2. Technical explanation of the equipment
Pulse oximetry is a non-invasive optical method that measures haemoglobin oxygen saturation through differential absorption of red (660 nm) and infrared (905 nm) light across the capillary bed. The PalmCare Pro processes this signal and simultaneously displays SpO2, pulse rate, pulse waveform (plethysmogram), alarm limits and status, perfusion index, battery status and trend memory. It incorporates perfusion index (PI), a parameter that quantifies the strength of pulsatile flow at the measurement site and helps assess signal quality, and 4 different screen modes to adapt the display to each clinical use. It supports adult, paediatric and neonatal patients simply by changing the type of SpO2 catheter connected to the device.
3. Technical Specifications
| Parameter | Value |
|---|---|
| Set type | Handheld pulse oximeter for adults, children and babies |
| Display | 3″ colour TFT LCD (240 x 400 pixels) |
| Screen modes | 4 different switchable views |
| Age groups | Adults, paediatric and neonates |
| Perfusion index (PI) | Yes (range 0.05 % – 20 %) |
| Trend memory | 20 days at 10-second intervals |
| Alarms | Visual and audible, with adjustable limits (low SpO2, pulse rate, low battery, probe off) |
| Protection | IPX1 |
| Operating temperature | 5 °C – 35 °C |
Measurement accuracy
| Parameter | Specification |
|---|---|
| SpO2 range | 0 % – 100 % |
| SpO2 accuracy | ±2 digits between 70 % – 100 % (adults and paediatric); ±3 digits (neonates) |
| SpO2 resolution | 1 % |
| Pulse rate range | 30 – 250 ppm |
| Pulse rate accuracy | ±3 digits |
| Pulse rate resolution | 1 ppm |
| Sensor wavelengths | Red 660 nm / Infrared 905 nm |
Power supply, dimensions and contents
| Characteristic | Value |
|---|---|
| Alkaline batteries | 4 x AA (battery life up to 10 hours) |
| Rechargeable battery | Lithium-ion (battery life up to 8 hours; charging time approx. 6 hours) |
| Power adapter | 100 – 240 V AC, 50 – 60 Hz (DC input +9 V) |
| Dimensions | 154 x 72 x 26 mm |
| Weight | Approx. 273 g (main unit, without power module) |
| Included accessories | Reusable adult SpO2 catheter, Li-Ion rechargeable battery, 4 AA batteries, protective case and user manual |
| Optional accessories | Paediatric and neonatal catheters (Y-type), SoftTouch catheter, extension cable, external mobile printer, PC monitoring software and forceps for infusion stand |
4. Equivalences and Cross-References
The PalmCare Pro belongs to the category of handheld pulse oximeters with colour screen, perfusion index and trend memory. There is no official equivalence table validated by the manufacturer that cross-references this model with specific codes from other brands; the following are products that can be matched at category level (same clinical indication: SpO2 and pulse monitoring in adults, paediatrics and neonates), with the warning that they are not interchangeable 1:1 and must be validated against each manufacturer’s technical data sheet before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Nonin Medical | PalmSAT 2500 / 2500A | N-2500 / N-2500A (base recargable N-2500C-UNIV) | Comparable by category (not interchangeable 1:1) | Handheld monitor with 72-hour memory, PureSAT technology, red LED screen (without PI or colour screen); powered by 4 AA batteries or base with rechargeable battery |
| Nonin Medical | Hand Held N-8500 | N-8500 | Comparable by category (not interchangeable 1:1) | Version without alarms, very robust, up to 100 hours on AA batteries; without perfusion index and without 20-day trend memory |
| Masimo | Radical RAD-57 (pulse co-oximeter) | MA-9216 (distributor code) | Comparable by category (not interchangeable 1:1) | Includes perfusion index (PI) and SET technology for motion/low perfusion, but adds co-oximetry (SpCO and SpMet); aimed at emergency care, with more parameters and higher cost |
There is no equivalence table validated by the manufacturer; consult the technical department before using this reference in tenders or replacing the device with a model from another brand.
5. Selection tips and variants of interest
Choose the version with rechargeable battery (ref. 40.50-2300) if your service needs continuous autonomy without relying on batteries: the lithium-ion battery offers up to 8 hours of operation and recharges in about 6 hours, as well as a lower replacement cost in the medium term. If use is occasional and with regular access to AA batteries, the basic PalmCare Pro variant (ref. 40.50-2240, without included Li-Ion battery) may be the most suitable option. Select the catheter according to the patient: the device is supplied with a reusable adult catheter; for paediatrics and neonates the specific catheter must be purchased (Y-type for neonate, reference from the 41.20-5264 family). If you are going to fix the monitor to an infusion stand or bed, request the securing forceps (ref. 41.50-2221) and the catheter extension cable (ref. 41.50-2032) for greater placement versatility. For data integration into the clinical record, consider the PC monitoring software available as an option.





Reviews
There are no reviews yet.