We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Handheld pulse oximeter HS10A (Ref. BRLHS10A) | Portable SpO2 and heart rate monitor with reusable Nellcor-type catheter for adults, children and infants

372,44 €

Handheld pulse oximeter HS10A (ref. BRLHS10A) for non-invasive measurement of oxygen saturation (SpO2) and heart rate in adults, children and infants. Compact, lightweight and reliable, it incorporates a reusable silicone catheter with a 7-pin Nellcor-type connection, colour LCD screen, perfusion index (0.05–20 %) and visual and audible alarms with user-adjustable limits. Powered by AA batteries (lithium or alkaline) with up to 30 hours of autonomy; designed for hospital, medical emergencies, prehospital care, medical transport and outpatient consultation. For large orders you can request a quote: ask your technical-commercial team at Cahnos for conditions.

In stock

International shipping. Import duties and taxes are payable by the recipient.

Reference
BRLHS10A

Description

1. Handheld pulse oximeter HS10A: reliable monitoring of SpO2 and pulse in any healthcare setting

The handheld pulse oximeter HS10A (SKU Cahnos: BRLHS10A) is a portable meter for blood oxygen saturation (SpO2) and heart rate, designed for professionals who need an accurate, fast and non-invasive reading: hospital, medical emergencies, prehospital care, patient transport, outpatient clinic and health centres. Its compact and lightweight format (72 x 142 x 32 mm and less than 500 g complete, with batteries and protective cover) facilitates transport and one-handed operation, without giving up the features of a larger monitor: colour LCD screen, perfusion index and visual and audible alarms with user-adjustable limits.

2. Pulse oximetry technology with reusable Nellcor-type catheter

Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin by differential absorption of red and infrared light through the capillary bed. The HS10A uses a reusable silicone catheter with a 7-pin Nellcor-type connection, whose special technology allows accurate measurements to be obtained even during movement or in situations of low perfusion (reduced blood flow), a critical point in patients with poor peripheral circulation.

The device starts measurement approximately 5 seconds after power-on and simultaneously displays on its colour LCD screen the oxygen saturation (SpO2), heart rate, pulse intensity bar, battery charge status and signal strength. It incorporates pitch-tone technology (pulse tone) as an acoustic indicator of pulse intensity and alarms, and a perfusion index (Pi) with a range of 0.05 % to 20 % to assess signal quality at the measurement point.

3. Technical Specifications

Parameter Value
Manufacturer Boscarol
Model HS10A
SKU Cahnos BRLHS10A
Set type Handheld pulse oximeter for spot measurement and monitoring
Measured parameters Oxygen saturation (SpO2) and heart rate
Sensor connection 7-pin Nellcor© type
Catheter Reusable silicone
Measurement start Approx. 5 seconds
Accuracy of SpO2 and heart rate See user manual
Perfusion index (Pi) Range 0.05 – 20 %; resolution 0.01 %
Low perfusion performance Pi ≥ 0.075 %: SpO2 and pulse correctly detectable; Pi < 0.075 %: not specified
Alarm functions Audible and visual: extreme values, low SpO2, pulse rate, low battery
Alarm limits User-adjustable
Alarm thresholds SpO2 90 %; high heart rate 120 bpm; low 50 bpm
Field of application Adults, children and infants
Intended use Hospital, emergency care, prehospital, outpatient
Display Colour LCD with alphanumeric indications
On-screen indications SpO2, heart rate, pulse intensity bar, battery status, signal strength
Pitch-tone technology Acoustic indicator of pulse intensity and alarm
Power supply Compatible with lithium and alkaline AA batteries
Battery life 30 hours of continuous use with new batteries at 25 °C (alarms disabled and screen on standby)
Applied part (IEC 60601-1) Type BF
Insulation class (IEC 60601-1) II
Dimensions 72 x 142 x 32 mm
Net weight < 500 g complete with batteries and protective cover

Available references

Reference Description
HS10A Factory reference
BRLHS10A Management SKU Cahnos (this product)

4. Equivalences and Cross-References

The manufacturer does not publish an official equivalence table cross-referencing the HS10A model with specific codes from other brands. Below are listed products that can be homologated by category within the Cahnos catalogue (same clinical indication: portable monitoring of SpO2 and pulse rate with reusable catheter and alarms); they should not be treated as interchangeable 1:1 substitutes without first validating specifications, certifications and tender documents.

Brand / Model Reference Cahnos Equivalence level
PalmCare Pro (handheld pulse oximeter with reusable catheter and adjustable alarms) 40.50-2240 Comparable by category (not interchangeable 1:1)
PalmCare Pro with rechargeable lithium-ion battery 40.50-2300 Comparable by category (not interchangeable 1:1)

Consult the technical-commercial department of Cahnos before using this reference in public tenders or replacing the device with a model from another brand.

5. Selection tips and variants of interest

  • Population: the HS10A is indicated for adults, children and infants; as it accepts a reusable catheter with Nellcor-type connection, the same device can be adapted to different patients by changing the sensor.
  • Intended use: hospital, medical emergencies, prehospital care and outpatient clinic; the 30-hour battery life with AA batteries ensures continuity in services without mains power or during transfers.
  • Alarms: the limits are user-adjustable (factory values: SpO2 90 %, high heart rate 120 bpm and low 50 bpm), allowing the device to be adapted to the centre’s protocols.
  • Low perfusion: the specified performance from a perfusion index Pi ≥ 0.075 % is a differentiating value compared to conventional finger pulse oximeters in patients with poor peripheral perfusion.
  • Catalogue variants: for monitoring with trend memory and perfusion index on a colour screen, consider the PalmCare Pro family (refs. 40.50-2240 and 40.50-2300); for lower-cost spot measurement, the finger pulse oximeters ME5 (40.22-5206), ME7 (40.21-5207) and ME10 (40.22-5205).
  • Maintenance: use quality AA batteries (lithium or alkaline), respect polarity, replace the batteries when the low-battery warning appears and clean the catheter and the device with suitable cloths between patients.

Additional information

Model

HS10A

Manufacturer reference

HS10A

Set type

Handheld pulse oximeter for spot measurement and monitoring

Measured parameters

Oxygen saturation (SpO2) and heart rate

Sensor connection

7-pin Nellcor© type

Catheter

Reusable silicone

Perfusion index

Range 0.05 – 20 %; resolution 0.01 %

Low perfusion performance

Pi ≥ 0.075 %: SpO2 and pulse correctly detectable; Pi < 0.075 %: not specified

Alarms

Audible and visual (extreme values, low SpO2, pulse rate, low battery); user-adjustable limits

Alarm thresholds

SpO2 90 %; high heart rate 120 bpm; low 50 bpm

Display

Colour LCD with alphanumeric indications (SpO2, heart rate, pulse intensity, battery, signal)

Measurement start

Approx. 5 seconds

Population

Adults, children and infants

Intended use

Hospital, emergency care, prehospital, outpatient

Power supply

Lithium and alkaline AA batteries

Battery life

30 hours of continuous use with new batteries at 25 °C (alarms disabled and screen on standby)

Applied part

Type BF (IEC 60601-1)

Insulation class

II (IEC 60601-1)

Dimensions

72 x 142 x 32 mm

Weight

< 500 g complete with batteries and protective cover

Documentation

Reviews

There are no reviews yet.

Be the first to review “Handheld pulse oximeter HS10A (Ref. BRLHS10A) | Portable SpO2 and heart rate monitor with reusable Nellcor-type catheter for adults, children and infants”

Your email address will not be published. Required fields are marked *