Light source adapter for connecting fibre optic cable to PENTAX light sources (Ref. 30837)

Price on request

The adapter for PENTAX light sources (ref. 30837, SKU GM30837) allows you to connect fibre optic (F.O.) cables to the light sources of the PENTAX manufacturer with a precise mechanical coupling and no light loss. Original accessory, manufactured as Class I medical device and sold in units of 1 piece, designed to complete and optimise cold lighting systems in rigid endoscopy, imaging diagnostics and ENT examination. Ideal for making the most of your existing cable fleet with already installed PENTAX equipment, ensuring stable, homogeneous, high-quality illumination in every examination. For large orders you can request a quote.

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM30837

Description

1. Introduction

The light source adapter for PENTAX (ref. 30837) is the accessory that will allow you to connect your fibre optic cables to the light sources of the PENTAX manufacturer. It is an original reference. With this adapter you can integrate your cables into PENTAX cold lighting equipment, maintaining efficient light transmission and a secure mechanical fit in every examination, without having to replace the cable or modify the source.

2. Technical explanation

In rigid endoscopy and in fibre optic (F.O.) lighting systems, light is transported from the cold light source to the endoscope, the optic or the instrument via fibre optic cables. Each manufacturer uses its own connection standard at the light source output port, so it is not always possible to directly couple a cable from one brand to the source of another. This adapter is inserted between the fibre optic cable connector and the PENTAX light source socket, providing the correct mechanical fit and optical alignment. A precise coupling prevents light leaks, slack and misalignments that would reduce field brightness and worsen image quality, critical aspects in diagnostic and surgical procedures.

3. Technical Specifications

Interconnection adapter designed to connect fibre optic cables to PENTAX light sources. Class I medical device, sold in units of 1 piece.

Manufacturer GIMA
Manufacturer reference 30837
SKU Cahnos GM30837
Sales unit 1 pc
Device type Medical device
Device class I
EAN 8023279308372
Product type Light source adapter for fibre optic cable
Compatible with Fibre optic cables and PENTAX light sources

Available references

Reference Description Sales unit
GM30837 Adapter for connecting fibre optic cables to PENTAX light sources (this product) 1 pc

4. Equivalences and Cross-References

This adapter is an original manufacturer reference (code 30837), distributed by Cahnos under SKU GM30837 (EAN 8023279308372). No 1:1 equivalents with adapters from other manufacturers for connecting fibre optic cables are documented in reliable sources. It belongs to the GM30830 to GM30837 light source adapter series, which allows cables to be connected to cold light sources from virtually all manufacturers on the market (STORZ-AESCULAP-MARTIN, WOLF, OLYMPUS, PENTAX, ACMI, among others). On the endoscope or optic side, it offers terminal adapters for STORZ/LUT (ref. 30840, SKU GM30840), WOLF (ref. 30841, SKU GM30841) and ACM/OLYMPUS-STRYKER (ref. 30842, SKU GM30842) connections. For any replacement or tender, please consult our technical department.

5. Selection tips and variants of interest

Before ordering this adapter, verify that the connection standard of your light source corresponds to PENTAX: in that case, the correct reference is GM30837. If your light source is from another manufacturer, select the corresponding adapter from the GM30830-GM30837 series to complete the lighting set. Also check the connector of your optic or endoscope and, if necessary, combine this adapter with the appropriate terminal adapter from the GM30840-GM30842 series. It is recommended to keep the adapters clean and free of dust in the coupling area to preserve optical transmission and avoid loss of brightness. For large orders you can request a quote: contact our technical-commercial team to formalise your order.

Additional information

Manufacturer reference

30837

Product type

Light source adapter for fibre optic cable

Compatibility

Fibre optic cables with PENTAX light sources

EAN

8023279308372

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

I

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF