Description
1. Product Presentation
The 3.5 x 1,800 mm fibre optic light cable (Ref. 30817) is the cold light transmission solution that your endoscopy department, operating theatre or practice needs for bright, stable, shadow-free illumination. This cable combines a protective armour with exceptional flexibility, keeping the optical properties intact even in the most demanding daily use.
This version is supplied without adapters: the cable is ready to be connected using the specific adapters of the family (Refs. 30830 to 30837) depending on the type of light source of your equipment, allowing you to configure the most suitable lighting set for each installation. High-quality product, manufactured in accordance with German MedGV standards and current international standards, with CE marking.
2. Technical explanation
In rigid and flexible endoscopy systems, light travels from the cold light source to the endoscope, the optics or the instrument through fibre optic (F.O.) cables. The light beam is transmitted through the fibres with minimal losses, ensuring optimal and homogeneous illumination of the field of view.
This cable uses high-quality fibre optics that guarantee maximum illumination and superior transmission. Its protective armour makes it resistant to bending, prevents burns and avoids loosening of the internal structure, while the silicone sleeve protects the cable from mechanical stress and facilitates handling. As it does not generate electrical interference, it is fully compatible with endoscopic surgery units and other electronic equipment in the operating theatre.
The surgical stainless steel connectors resist wear and corrosion, extending the service life of the assembly. In addition, the end of the cable intended for the light source withstands temperatures up to 134 °C, an essential requirement for its sterilisation in an autoclave.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Product type | High-transmission surgical fibre optic light cable (F.O.) |
| Manufacturer | GIMA |
| Manufacturer reference | 30817 |
| Diameter | 3.5 mm |
| Length | 1,800 mm (1.8 m) |
| Adapters | Without adapters (version «without adapters») |
| Frame | Shielded and highly flexible |
| Protection | Anti-tension silicone sleeve |
| Finishes | Surgical stainless steel connectors |
| Thermal resistance | Light source end resistant up to 134 °C |
| Sterilisation | Steam autoclavable (12-month warranty) |
| Resistance | Kink-resistant and burn-proof |
| Electromagnetic compatibility | Without electrical interference with endoscopic surgery units |
| Regulatory standard | Compliant with German MedGV standards and international standards, CE marking |
Product data
| Sales unit | 1 pc |
|---|---|
| Device type | Medical device |
| Device class | I |
| EAN | 8023279308174 |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| GM30817 | Fibre optic light cable 3.5 x 1,800 mm, without adapters (this product) | 1 pc |
4. Equivalences and Cross-References
This reference corresponds to code 30817, distributed by Cahnos under SKU GM30817 (EAN 8023279308174). No reliable sources document 1:1 equivalences of this cable with references from other manufacturers; it is recommended to use the original cable to guarantee optical quality and mechanical compatibility with the family adapters.
The version with adapters (same cable construction with already adapted stainless steel connectors) and the complementary accessories of the lighting family available from Cahnos are:
| SKU | Description |
|---|---|
| GM30830 | Cable/light source adapter (ref. 30830) |
| GM30831 | Cable/light source adapter STORZ – AESCULAP – MARTIN (ref. 30831) |
| GM30832 | Cable/light source adapter WOLF – HENKE SASS – DYONICS – MEDICON – COMEG (ref. 30832) |
| GM30833 | Cable/light source adapter OLYMPUS (ref. 30833) |
| GM30834 | Cable/light source adapter ACMI (ref. 30834) |
| GM30837 | Cable/light source adapter PENTAX (ref. 30837) |
| GM30840 / GM30841 / GM30842 | Terminal adapters for STORZ/LUT, WOLF and ACM/OLYMPUS-STRYKER optics |
| GM30803 | GIMALED LED light source for endoscopy and fibre optics |
5. Selection tips and variants of interest
This version without adapters is the ideal option when the cable will be part of a lighting system that already has the appropriate source adapters or when you wish to custom-configure the connection. Before placing your order, check the connector of your light source: if it is, select the adapter GM30830; for STORZ/AESCULAP/MARTIN, WOLF, OLYMPUS, ACMI or PENTAX sources, choose the corresponding adapter from the GM30831 to GM30837 series.
If you work with optics and endoscopes with STORZ/LUT, WOLF or ACM/OLYMPUS-STRYKER connection types, complete the assembly with the terminal adapters GM30840, GM30841 or GM30842. Always keep the coupling area clean and free of dust to preserve optical transmission. All products in this family are supplied: request availability and conditions from our technical-commercial team at Cahnos. For large orders you can request a quote.