We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Uterine dynamics TOCO catheter (tocodynamometer) for BT-300 fetal monitor – medical ECONET – Original replacement, new version, water-resistant – Ref. 36.70-3035 (MEC36.70-3035)

199,00 €

Original replacement TOCO catheter for the fetal monitor BT-300 de medical ECONET. Designed for the non-invasive detection of uterine contractile activity (dynamics) during pregnancy and childbirth, it complements the monitoring of fetal heart rate and turns it into a complete CTG examination. Robust and water-resistant design for daily use in consultation, clinic, delivery room and midwifery care; quick and simple connection to the equipment, ideal as a spare or reserve catheter. Manufacturer reference 36.70-3035 (SKU Cahnos MEC36.70-3035). Not compatible with the first generation of the BT-300 (series BI100XXXX). B2B product, sold on quotation.

International shipping. Import duties and taxes are payable by the recipient.

Reference
MEC36.70-3035

Description

1. Commercial Introduction

The BT-300 Toco-Probe (nueva versión) is the original replacement TOCO catheter from medical ECONET for the BT-300 fetal monitor. It allows reliable and non-invasive recording of uterine contractile activity during pregnancy and childbirth, complementing the recording of fetal heart rate to complete a comprehensive cardiotocography (CTG). It is the ideal solution for hospitals, obstetric practices, clinics, midwives and nursing staff who need to replace or expand the equipment of their monitors, or who always want to have a spare catheter ready to use.

2. Technical Explanation

The TOCO catheter (tocodynamometer) is an external pressure transducer that detects mechanical changes produced in the abdominal wall during uterine contractions. These changes are converted into an electrical signal that the BT-300 monitor processes and represents on the uterine dynamics curve, allowing the frequency, duration and relative intensity of contractions to be assessed during prenatal care, labour and childbirth.

As an original accessory of the BT-300 system, this catheter is specifically optimised for this equipment, ensuring simple integration, stable TOCO measurement and easy incorporation into the examination workflow. Its water-resistant design facilitates hygienic cleaning in the daily clinical practice, and its robust construction is designed for continuous professional use, ensuring a long service life. It is indicated as a replacement or spare to keep the system always operational.

3. Technical specifications and available references

Field Specification
Product type TOCO catheter (tocodynamometer) for external measurement of uterine activity
Brand medical ECONET
Manufacturer / original distributor medical ECONET GmbH
Function Non-invasive detection of uterine contractions (dynamics) for CTG recording
Compatibility BT-300 systems from medical ECONET
Version New version; not suitable for the first generation with serial number BI100XXXX
Water resistance Yes, water-resistant design for hygiene and daily use
Intended use Pregnancy, prenatal care, labour and childbirth (clinical practice, hospital, midwives)
ECONET category of origin Fetal · Accessories (Zubehör)

Available references

Code Description
MEC36.70-3035 Reference Cahnos (SKU)
36.70-3035 Manufacturer’s reference (medical ECONET)

Compatibility note: this catheter corresponds to the new version of the BT-300 Toco-Probe and is not suitable for the first generation of the BT-300 with serial number BI100XXXX.

4. Equivalences and Cross-References

This article belongs to the line of original accessories of the CTG ecosystem from medical ECONET. It is marketed under the references MEC36.70-3035 (SKU Cahnos) and 36.70-3035 (manufacturer’s reference), which designate the same product: the BT-300 uterine dynamics TOCO catheter in its new version.

There is no validated equivalence table that authorises replacement with TOCO catheters from other manufacturers: as it is a specific transducer of the BT-300 system, the compatibility of the connector and the signal must always be verified with the specific monitor. It is recommended to use the original accessory from medical ECONET to guarantee the quality and reliability of the uterine dynamics recording.

5. Selection tips and variants of interest

Always verify the exact model and serial number of your equipment before purchasing the catheter: this Toco-Probe is designed for BT-300 systems from medical ECONET and is not compatible with the first generation (series BI100XXXX). If you need to replace or complete other elements of your BT-300 monitoring station, in the Cahnos catalogue you will find accessories from the same family, such as the ultrasound probe US-Probe for BT-300 (Ref. 36.70-3040), the original CTG recording paper for BT-300 (Ref. 70.70-3020) and the event marker compatible with the BT-300 series (Ref. MEC36.70-3482).

Always have a spare TOCO catheter or replace the damaged unit to ensure that your BT-300 remains operational at all times. For institutional orders, tenders or volume conditions, contact our technical-commercial department: this product is sold on quotation.

Additional information

Manufacturer reference

36.70-3035

Product type

TOCO catheter (tocodynamometer) for uterine dynamics

Manufacturer

medical ECONET GmbH

Function

Non-invasive detection of uterine contractile activity for CTG recording

Compatibility

BT-300 systems from medical ECONET

Version

New version; not suitable for the first generation (series BI100XXXX)

Water resistance

Yes

Intended use

Pregnancy, prenatal care, labour and childbirth

Source category

Fetal · Accessories (Zubehör)

Reviews

There are no reviews yet.

Be the first to review “Uterine dynamics TOCO catheter (tocodynamometer) for BT-300 fetal monitor – medical ECONET – Original replacement, new version, water-resistant – Ref. 36.70-3035 (MEC36.70-3035)”

Your email address will not be published. Required fields are marked *