We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Fetal ultrasound transducers compatible with Philips/HP and GE Corometrics | Replacement and spare parts for fetal CTG monitoring (Ameritus)

Price on request

Fetal ultrasound transducers compatible with the most common cardiotocography monitors on the market: HP®/PHILIPS® (series 8040 and series 1350) and GE®/Corometrics® (models 115, 116, 118, 120, 129, 145, 150, 151, 155, 170, 250, 259 and 340). Spare parts and expansion of equipment that ensure reliable performance and clinical safety during fetal well-being recording. Wide range at competitive prices, marketed on quotation for centres and tenders.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ABM-TRANSDUCTORES-FETALES-ULTRASONIDOS

Description

1. Commercial Introduction

The fetal ultrasound transducers from Ameritus are the ideal replacement and expansion solution for obstetrics and gynaecology departments that need to keep their fetal monitors operational with full warranty. This wide range is designed to be compatible with the most widely used hospital equipment: HP®/PHILIPS® monitors (series 8040 and series 1350) and GE®/Corometrics® monitors (models 115, 116, 118, 120, 129, 145, 150, 151, 155, 170, 250, 259 and 340).

Each transducer ensures the performance and clinical safety required to obtain quality cardiotocographic recordings, at competitive prices. It is the practical choice for replacing a damaged probe, expanding the equipment of a delivery room or having a backup sensor that prevents interruption of healthcare activity.

2. Technical explanation of the equipment

The fetal ultrasound transducer is the external sensor that enables non-invasive recording of fetal heart rate (FCF) during cardiotocographic monitoring (CTG). It uses Doppler ultrasound technology: the transducer emits ultrasound waves that, when reflected by the movement of the fetal cardiac structures, generate the signal that the monitor processes and displays on screen together with the recording of uterine dynamics (TOCO).

As they are compatible transducers, they reproduce the operating frequency and the sensitivity and penetration parameters specified for each monitor family, ensuring correct electrical and mechanical coupling. They are used on the maternal abdomen with ultrasound transmission gel, as indicated in the equipment manual.

3. Technical specifications and tables

These transducers are selected according to the installed monitor family. The compatibility verified in the catalogue is detailed below:

Compatible monitor family Series / Models
HP® / PHILIPS® Series 8040, series 1350
GE® / Corometrics® 115, 116, 118, 120, 129, 145, 150, 151, 155, 170, 250, 259, 340
Characteristic Detail
Product type Fetal ultrasound transducer (Doppler) for fetal monitoring
Application Non-invasive recording of fetal heart rate (FCF) in antepartum and intrapartum CTG monitoring
Brand Ameritus
Compatibility HP®/PHILIPS® series 8040 and 1350; GE®/Corometrics® models 115, 116, 118, 120, 129, 145, 150, 151, 155, 170, 250, 259 and 340
Manufacturer reference ABM-TRANSDUCTORES-FETALES-ULTRASONIDOS
Intended use Obstetrics and gynaecology clinics, labour and delivery rooms
Commercialisation On request, no public list price

4. Equivalences and Cross-References

These transducers cover the most common compatibility ranges on the market: the HP®/PHILIPS® family (series 8040 and 1350, typical of widely installed bedside cardiotocography monitors) and the GE®/Corometrics® family (models 115 to 340). There is no manufacturer-validated 1:1 equivalence table for replacement with transducers from other brands; before considering any third-party alternative, the connector, frequency, sensitivity and compatibility with the specific monitor model must be checked, always consulting our technical-commercial department.

In our catalogue, it can be cross-referenced with other fetal monitoring accessories, such as the SMART 5 ultrasound probe from medical ECONET (Ref. MEC80.10-7034) for the SMART series, or the portable Doppler detectors and cardiotocographs from the fetatrack family by AB Medica Group.

5. Selection tips and variants of interest

Identify your equipment first: verify the exact brand and model of your fetal monitor (HP®/PHILIPS® series 8040 or 1350, or GE®/Corometrics® 115 to 340) and confirm with our technical team the correct transducer reference, as each monitor family may require its specific probe.

Consumables and maintenance: always use ultrasound-specific transmission gel to optimise coupling and signal quality, and clean the transducer between patients according to the manufacturer’s instructions. To complete your monitoring system, combine these transducers with elastic fastening straps (e.g., disposable CTG band sets) and with the recording paper compatible with your printer.

For institutional orders, tenders or ongoing supply contracts, contact the technical-commercial department of Cahnos to confirm compatibility, lead times and quotation conditions.

Additional information

Brand

Ameritus

Manufacturer

AB Medica Group

Product type

Fetal ultrasound transducer (Doppler) for cardiotocographic monitoring (CTG)

Application

Non-invasive recording of fetal heart rate (FCF)

Technology

Doppler ultrasound

hp philips compatibility

Series 8040, series 1350

ge corometrics compatibility

115, 116, 118, 120, 129, 145, 150, 151, 155, 170, 250, 259, 340

Reference

ABM-TRANSDUCTORES-FETALES-ULTRASONIDOS

Intended use

Obstetrics and gynaecology clinics, labour and delivery rooms

Reviews

There are no reviews yet.

Be the first to review “Fetal ultrasound transducers compatible with Philips/HP and GE Corometrics | Replacement and spare parts for fetal CTG monitoring (Ameritus)”

Your email address will not be published. Required fields are marked *