Description
1. Introduction
The Rosen ear suction cannula is the reference instrument for keeping the external auditory canal clean and clear during ENT examination. Manufactured in Italy, this version of Ø 3 mm (16.1 cm) offers a medium gauge that combines effective suction with comfortable and safe handling, ideal for daily use in ear, nose and throat (ENT) clinics, primary care centres and hearing diagnostic units.
By incorporating a Luer tip adapter and a thumb-operated control valve (thumb valve), the professional can modulate the suction intensity instantly and ergonomically, without releasing the instrument or interrupting the examination.
2. Technical explanation of the equipment
In the otological suction system, the cannula is connected to the vacuum circuit or to the practice’s suction unit via the Luer tip adapter. The conical geometry of the Luer connection ensures a firm and airtight coupling that prevents air leaks, so that the negative pressure generated by the suction unit is transmitted entirely to the cannula tip. The control valve (valvola a sfera) allows the professional to open or close the suction passage with the thumb, precisely regulating the force applied to the patient’s ear and avoiding excessive suction that could irritate the canal.
This is a reusable ENT instrument: after each use it must be cleaned and reprocessed following the usual sterilisation protocols for surgical instruments, always checking the correct condition of the tip and the control valve.
3. Technical Specifications
The verified data from the manufacturer’s catalogue are detailed below:
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 26798 |
| Reference Cahnos (SKU) | GM26798 |
| Diameter | Ø 3 mm |
| Length | 16.1 cm |
| Connection | Luer tip adapter |
| Suction control | Thumb-operated control valve (thumb valve) |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | I |
| CND | L030101 |
| GMDN | 36269 |
| EAN | 8023279267983 |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| 26798 | Rosen ear suction cannula Ø 3 mm (16.1 cm) with Luer tip adapter and control valve (this product) | 1 pc |
| 26797 | Rosen ear suction cannula Ø 1.5 mm (15.5 cm) with Luer tip adapter and control valve | 1 pc |
| 26807 | Suction cannula compatible with the Luer adapter (manufacturer’s code) | 1 pc |
| 26799 | Luer tip suction adapter for cannulas 26797/26798 and 26807 (replacement) | 1 pc |
4. Equivalences and Cross-References
This cannula corresponds to the manufacturer’s own coding (ref. 26798, EAN 8023279267983). No equivalence table validated by the manufacturer that cross-references this code with official codes from other manufacturers has been found in reliable sources, so no direct third-party substitutions are indicated.
Within the manufacturer’s own range, the Rosen ear suction cannula Ø 3 mm is part of the otological suction family, together with the Rosen cannula Ø 1.5 mm (ref. 26797), the cannula compatible with Luer adapter (ref. 26807) and the replacement Luer tip suction adapter (ref. 26799), all of which belong to the ENT instrument category. For any compatibility with instruments or suction equipment from other brands, it is recommended to validate the type of Luer connection in advance with the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
To set up a complete otological suction table, combine this Ø 3 mm cannula with the smaller gauge Rosen variant of Ø 1.5 mm (ref. 26797), recommended for narrower ear canals or paediatric patients. If the Luer tip adapter becomes damaged or lost, it can be replaced with the original replacement (ref. 26799) without needing to replace the entire cannula, provided you verify compatibility with your reference.
Periodically inspect the condition of the tip, the Luer adapter and the control valve, especially after each cleaning and sterilisation cycle, to ensure airtight, safe and durable suction. For large orders you can request a quote: contact your technical-commercial advisor at Cahnos for supply conditions and delivery times.





Reviews
There are no reviews yet.