Description
1. Commercial Introduction
The CO2 sampling nasal cannula (Ref. 33694) is the original single-use accessory designed for the portable capnograph-oximeter PC-900B (Ref. 33698). It is the indicated solution for continuously monitoring the ventilation of non-intubated, spontaneously breathing patients or during sedation and medical transport, without the need for an artificial airway. Manufactured and distributed by Cahnos, it is part of the consumables range for the PC-900B platform together with the sampling line (Ref. 33700), the airway adapter (Ref. 33701) and the water filter (Ref. 33699).
2. Technical explanation of the procedure
The PC-900B capnograph-oximeter uses a sidestream suction measurement system: the nasal cannula is placed in the patient’s nostrils and a small suction flow continuously extracts a sample of exhaled gas which is transported to the device’s analysis chamber. There, the sensor determines the carbon dioxide concentration at the end of expiration (EtCO2) and calculates the respiratory rate (RR), key data for assessing ventilation and for early detection of hypoventilation, obstruction or circuit disconnection.
As a single-use product, this cannula eliminates the risk of cross-contamination between patients and maintains measurement reliability in each monitoring session. It is the accessory of choice for non-intubated patients without an artificial airway, complementing the airway adapter (Ref. 33701), which is reserved for intubated patients or those connected to a face mask.
3. Technical Specifications
Single-use (disposable) CO2 sampling nasal cannula, compatible with the PC-900B capnograph-oximeter (Ref. 33698). The product data and the available references in the range are detailed below.
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 33694 |
| SKU Cahnos | GM33694 |
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | I |
| CND | R9099 |
| EAN | 6974774500216 |
Main characteristics
| Characteristic | Detail |
|---|---|
| Accessory type | CO2 sampling nasal cannula |
| Use | Single-use (disposable) |
| Compatibility | Capnograph-oximeter PC-900B (Ref. 33698) |
| Measurement method | Sidestream suction |
| Monitored parameters | End-tidal CO2 (EtCO2) and respiratory rate |
| Target population | Non-intubated patients |
Available references
| Reference | Product | Sales unit |
|---|---|---|
| 33694 (GM33694) | CO2 sampling nasal cannula for PC-900B capnograph (this product) | 1 pc |
| 33698 (GM33698) | Portable capnograph-oximeter PC-900B | 1 pc |
| 33699 (GM33699) | Disposable water filter for PC-900B | 1 pc |
| 33700 (GM33700) | Disposable sampling line for PC-900B | 1 pc |
| 33701 (GM33701) | Disposable airway adapter for PC-900B | 1 pc |
4. Equivalences and Cross-References
Reference 33694 (SKU Cahnos GM33694) is the original code for the CO2 sampling nasal cannula for the PC-900B capnograph-oximeter (Ref. 33698), as listed in the Product_DB catalogue. There is no official equivalence table validated by the manufacturer cross-referencing this consumable with third-party sampling nasal cannulas: the connector, the suction flow rate and the sidestream system are specific to the PC-900B platform and must not be replaced with accessories from other brands without prior technical validation.
Within the same catalogue, the airway and sampling range for capnography is completed with the disposable sampling line (Ref. 33700), the disposable airway adapter (Ref. 33701) and the water filter (Ref. 33699), all of which are complementary consumables for the same device. For any substitution in tenders, consult the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
For correct monitoring, use the CO2 sampling nasal cannula (Ref. 33694) in non-intubated patients and breathe normally during sample collection; for patients with an artificial airway, use the airway adapter (Ref. 33701) together with the sampling line (Ref. 33700). Replace the water filter (Ref. 33699) regularly to protect the device sensor from moisture and condensation.
As a single-use product, it is recommended to use a new cannula per patient to prevent cross-contamination and to maintain sufficient stock for replenishment programmes and fleet allocations. Always verify that you are ordering reference 33694 (SKU GM33694), specific to the PC-900B capnograph. For volumes, tenders or special conditions for healthcare facilities, request a quote from your technical-commercial advisor at Cahnos. For large orders you can request a quote.