We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Tympanometer/audiometer Maico TouchTymp MI 36 – Diagnostic tympanometry, acoustic reflexes, reflex decay, ETF and air and bone conduction audiometry with 10.4″ touchscreen and integrated printer | Ref. ABM-TIMPANOMETRO-AUDIOMETRO-TOUCHTYMP-MI-36

Price on request

Tympanometry and audiometry in a single desktop device with complete middle-ear diagnostics. The Maico TouchTymp MI 36 combines tympanometry (probe tones of 226, 678 and 800 Hz, with optional high-frequency 1 kHz for newborns), ipsilateral and contralateral acoustic reflexes, reflex decay, Eustachian tube function test (ETF) for intact and perforated eardrums, and air and bone conduction audiometry. Its fully touchscreen 10.4″ display, compact design and integrated printer streamline daily workflow, with data transmission to PC via the optional MAICO Sessions software (compatible with OtoAccess® and Noah). Product subject to quotation; consult B2B conditions.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ABM-TIMPANOMETRO-AUDIOMETRO-TOUCHTYMP-MI-36
Brand
Maico

Description

Tympanometry and audiometry in a single device

The Maico TouchTymp MI 36 combines diagnostic middle-ear analysis and clinical audiometry in a single, compact, space-saving desktop unit: the ENT, audiology, paediatrics or primary care specialist has all tests in one device, with a fully touchscreen interface of 10.4 inches that allows switching between tests without reorganising the workspace. Customisable to meet the individual needs of each department, it improves daily workflow without needing to change equipment or expand the desk.

Technical explanation of the equipment

The touchTymp MI 36 is an acoustic impedance analyser with integrated audiometry. It performs diagnostic tympanometry with probe tones of 226 Hz, 678 Hz and 800 Hz, with an optional high-frequency tone of 1 kHz ideal for obtaining reliable results in newborns. It incorporates detailed standard protocols for immediate operation of screening and diagnostic processes: tympanometry, tympanometry with automatic or fixed acoustic reflexes, reflex decay (ipsilateral and contralateral) and Eustachian tube function test (ETF) for both intact and perforated eardrums. The acoustic reflex stimuli cover 500 Hz, 1 kHz, 2 kHz and 4 kHz and broadband (BB), high-pass (HP) and low-pass (LP) noise, with ipsilateral and contralateral stimulation. Audiometry includes air conduction (AC) and bone conduction (BC).

The box probe incorporates a unique light bar that shows the impedance test progression in real time and can be attached to the patient’s clothing for controlled handling; the light indicator shows the ear being tested and the result. Reports are printed instantly with the integrated printer when the probe is placed in its holder, and results can be transferred to a PC for long-term storage, full-page printing or creation of PDF files that can be integrated into the electronic health record. The optional MAICO Sessions software connects with the OtoAccess® and Noah patient databases.

Technical specifications

Characteristic Specification
Brand / Model Maico TouchTymp MI 36 (touchTymp touch series)
Reference (SKU) ABM-TIMPANOMETRO-AUDIOMETRO-TOUCHTYMP-MI-36
Set type Tympanometer/audiometer: tympanometry, acoustic reflexes and audiometry in a single device
Display Fully touchscreen, high resolution, 10.4″ (approx. 26.4 cm), fast transitions
Probe tones 226 Hz, 678 Hz and 800 Hz; optional high-frequency 1 kHz probe (ideal for newborns)
Acoustic reflex stimuli 500 Hz, 1 kHz, 2 kHz and 4 kHz; broadband (BB), high-pass (HP) and low-pass (LP) noise; ipsilateral and contralateral
Available tests Diagnostic tympanometry, automatic or fixed acoustic reflexes, reflex decay and Eustachian tube function (ETF) for intact and perforated eardrums
Audiometry Air conduction (AC) and bone conduction (BC)
Catheter Box probe with real-time progress light bar and ear and result indicator; attaches to patient’s clothing
Printer Integrated; automatic printing when the probe is placed in its holder
Connectivity / software Data transfer to PC; optional MAICO Sessions software compatible with OtoAccess® and Noah patient databases
Configuration Customisable to meet the individual needs of the professional
Format Compact benchtop device
Scope of use ENT, audiology, paediatrics, primary care and audiological diagnostic services

Available references

Reference (SKU) Product Note
ABM-TIMPANOMETRO-AUDIOMETRO-TOUCHTYMP-MI-36 Tympanometer/audiometer Maico TouchTymp MI 36 Complete diagnostic configuration; see options (1 kHz probe tone and accessories)

Enquire about the installation of audiometric booths.

Equivalences and cross-references

The reference ABM-TIMPANOMETRO-AUDIOMETRO-TOUCHTYMP-MI-36 corresponds to the Cahnos distribution code for the Maico TouchTymp MI 36 tympanometer/audiometer (abmedica catalogue). There is no manufacturer-validated 1:1 equivalence table cross-referencing this code with third-party codes; it is recommended to consult the technical department before using it in tenders or stock substitutions. At a functional category level, impedance analysers with audiometry from manufacturers such as Interacoustics (Titan series), Inventis, GN Otometrics/Madsen, Grason-Stadler (GSI) or Amplivox cover similar clinical indications for middle-ear examination, although they are not 1:1 interchangeable: before any substitution, the probe tones (226/678/800 Hz), ipsi/contralateral reflex frequencies, presence of reflex decay and ETF test, air and bone conduction audiometry, printer and data management software must be verified field by field.

Selection tips and variants of interest

The TouchTymp MI 36 is the recommended option when your department needs the complete diagnostic package in a single unit: tympanometry with 678 Hz and 800 Hz tones, reflex decay, ETF for intact and perforated eardrums, and air and bone conduction audiometry. If you only need middle-ear screening, consider the TouchTymp MI 24 from the same family; if you combine tympanometry with air conduction audiometry (with optional bone conduction), the TouchTymp MI 26 is the most accessible alternative; and if you do not require audiometry but do need advanced middle-ear diagnostics, the TouchTymp MI 34 covers 678/800 Hz tones, decay and ETF. For examinations in the paediatric population, the RaceCar animation is available in the touchTymp line. For centralised patient management, activate the optional MAICO Sessions software with connection to OtoAccess® or Noah and request from your distributor the optional high-frequency probe tone of 1 kHz. For institutional orders, tenders or supply contracts, contact the technical-commercial department of Cahnos to confirm the exact configuration and obtain a formalised quotation under B2B conditions.

Additional information

Brand

Maico

Set type

Combined benchtop tympanometer/audiometer

Model

TouchTymp MI 36

Display

High-resolution touchscreen, 10.4″ (approx. 26.4 cm)

Probe tones

226 Hz, 678 Hz and 800 Hz; 1 kHz optional

Acoustic reflex stimuli

500 Hz, 1 kHz, 2 kHz, 4 kHz, BB, HP and LP noise (ipsilateral and contralateral)

Tests

Tympanometry, acoustic reflexes, reflex decay, ETF for intact and perforated tympanic membranes

Audiometry

Air conduction (AC) and bone conduction (BC)

Catheter

Box probe with illuminated progress bar and ear and result indicator

Printer

Integrated with automatic printing

Connectivity

Data transfer to PC; optional MAICO Sessions software, compatible with OtoAccess® and Noah

Configuration

Customisable

Format

Compact benchtop

Reviews

There are no reviews yet.

Be the first to review “Tympanometer/audiometer Maico TouchTymp MI 36 – Diagnostic tympanometry, acoustic reflexes, reflex decay, ETF and air and bone conduction audiometry with 10.4″ touchscreen and integrated printer | Ref. ABM-TIMPANOMETRO-AUDIOMETRO-TOUCHTYMP-MI-36”

Your email address will not be published. Required fields are marked *