Description
1. Reliable power for your Welch Allyn Propaq MFR monitor
The Welch Allyn Propaq MFR 501-00008-01 battery (ref. Cahnos 88888512) is the power replacement indicated for the portable vital signs monitors Welch Allyn Propaq MFR. It is the solution that restores full autonomy to the equipment when no mains power is available: patient transfers, emergencies, ambulances, intra-hospital transport or any interruption of supply where continuity of monitoring cannot tolerate pauses.
It is a rechargeable battery ready to install in the original compartment without modifications or tools, designed for medical electronics services, biomedical engineering, emergency departments, ICUs and hospital purchasing. A professional spare part with warranty to keep your fleet of monitors always operational.
2. How this battery works in your monitor
The Welch Allyn Propaq MFR monitors are compact bedside and transport devices that integrate a display, parametric modules (ECG, SpO2, non-invasive blood pressure, temperature) and signal processing electronics. To operate without depending on the mains, they incorporate an internal rechargeable nickel-metal hydride (Ni-MH) battery, a chemistry recognised for its robustness in continuous charge cycles and its predictable behaviour in medical devices of this generation.
This cell delivers a nominal voltage of 8 V with a capacity of 6.4 Ah (6,400 mAh), which represents a total energy of 51.2 Wh. Recharging is carried out automatically while the monitor remains connected to its charger or to the mains. When autonomy is appreciably reduced or the equipment warns of low battery after a few hours of charge, it is time to replace the battery. Always keep the spare cell in good condition and use the monitor’s original charger to respect the equipment’s charging parameters.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Application | Vital signs monitor Welch Allyn Propaq MFR |
| Original reference (OEM) | 501-00008-01 |
| Reference Cahnos (SKU) | 88888512 |
| Technology | Ni-MH (nickel-metal hydride) rechargeable |
| Nominal voltage | 8 V |
| Capacity | 6.4 Ah (6,400 mAh) |
| Energy | 51.2 Wh |
| Weight | Approximately 0.55 kg |
| Dimensions | 90 x 110 x 60 mm |
| Load | Automatic in the monitor (rechargeable) |
| Device manufacturer | Welch Allyn |
| Presentation | 1 unit |
| Recycling | WEEE |
Technical note: the voltage, capacity and energy indicated correspond to the declared specification for reference 501-00008-01. Always verify the label of the removed unit and the compartment of your monitor before replacement.
4. Equivalences and Cross-References
Reference 501-00008-01 appears in the internal register and in specialised distribution as the OEM code under which Welch Allyn identifies the internal battery of the Propaq MFR platform. It has not been independently located in the manufacturer’s public catalogues consulted during the preparation of this datasheet, so it is recommended to confirm it against the label of the unit in service before use in tendering.
There is no equivalence table validated by the manufacturer that authorises the direct cross-reference of the 501-00008-01 with third-party codes; aftermarket replacements for this application must be verified one by one —voltage, capacity, chemistry, connector, charging protocol and compartment dimensions— against the specific unit. Among the replacement families for vital signs monitors that usually cover this category are biomedical pack manufacturers such as OSI Batteries (Unipower), Cameron Sino or Cables and Sensors / Interstate Battery; no specific codes are listed here because they have not been verified against an official source.
Within the transport monitor range itself, they are not interchangeable: the Welch Allyn Propaq-LT platform uses its own battery (ref. 008-0857-00, ref. Cahnos 88888181) and the ZOLL Propaq M / MD monitor-defibrillators use the SurePower II battery (ref. 8000-0580-01, ref. Cahnos 88881047), with different voltages and chemistry. There is no equivalence table validated by the manufacturer; consult the technical department before using this reference in tendering or replacing the battery of a monitor in use.
5. Selection tips and variants of interest
Identify the exact model: this battery corresponds to the Welch Allyn Propaq MFR monitor associated with reference 501-00008-01. Confirm the label of the installed battery and do not exchange it for batteries from other models of the same brand (Propaq-LT, VSM300, VSM6000, Spot LXI, Connex Spot) without technical validation: each device accepts a specific voltage, capacity, chemistry and geometry.
Ni-MH battery care: avoid frequent deep discharges and keep the cell charged if the equipment is to remain idle for long periods; Ni-MH cells self-discharge slowly, so periodic recharging is recommended. Replace the battery when autonomy is appreciably reduced or the monitor indicates low battery, and use only the equipment’s original charger.
Variants of the same family at Cahnos: battery 8.4 V 1.9 Ah for Propaq-LT (ref. 88888181), battery 10.8 V 6.75 Ah for VSM6000 (ref. 88888849), battery 7.2 V 3.2 Ah for Connex Spot (ref. 88889217), battery 6.4 V 6 Ah for LXI (refs. 88881196 / 88889726) and SurePower II battery for ZOLL X Series / Propaq M (ref. 88881047). Do not interchange these references between models.
For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, lead times and a formalised quotation.





Reviews