We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Li-ion Battery 10.8 V 6.6 Ah (71.28 Wh) for Spacelabs Medical mCare 300 / mCare 300D / ELS5 Vital Signs Monitor | Replaces 147-0127-00 and 146-0127-00 | Ref. 88888305

160,00 €

Li-ion battery 10.8 V and 6.6 Ah (71.28 Wh) for the Spacelabs Medical mCare 300 vital signs monitor, a direct replacement that substitutes the manufacturer’s original reference 147-0127-00 (also documented as 146-0127-00 for the same mCare 300 / ELS5 platform). Rechargeable battery that maintains monitoring of ECG, SpO2, non-invasive blood pressure and temperature during transfers, power cuts or continuous operation. Direct installation in the equipment compartment and automatic recharging with the monitor connected to the mains. Traceable and proven quality solution for medical electronics services, hospital maintenance and institutional purchasing. Ref. Cahnos 88888305. Price per unit.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888305

Description

1. Reliable power for your Spacelabs Medical mCare 300 monitor

At Cahnos we offer the replacement battery for the Spacelabs Medical mCare 300 vital signs monitor (Ref. Cahnos 88888305), corresponding to the original manufacturer reference 147-0127-00. This is a rechargeable lithium-ion (Li-ion) accumulator of 10.8 V and 6.6 Ah that restores full autonomy to the device for continuous patient monitoring, even when the monitor is not connected to the mains.

It is the ideal solution for biomedical engineering services, medical electronics maintenance and hospital purchasing departments looking for a traceable and quality-proven spare part at a highly competitive cost compared to the official replacement, without compromising the reliability required for patient monitoring in ICU, emergency, operating theatre, hospital ward and intrahospital transport. In the aftermarket, the same pack is also documented for the mCare 300D and ELS5 platforms.

2. Technical explanation: how this battery works

The Spacelabs Medical mCare 300 is a multiparameter vital signs monitor that records ECG, oxygen saturation (SpO2), non-invasive blood pressure (NIBP) and temperature. To ensure patient monitoring when the device is disconnected from the mains, during transfers or in the event of a power outage, the monitor incorporates an internal rechargeable battery that acts as a backup source: while plugged in, the accumulator recharges automatically; when disconnected or during a supply interruption, the battery takes over powering the control electronics, the display and the alarms without interrupting monitoring.

This battery uses lithium-ion (Li-ion) chemistry, free from memory effect and with good energy density, with a nominal voltage of 10.8 V and a capacity of 6.6 Ah (71.28 Wh). When runtime noticeably decreases or the monitor gives an early low-battery warning, it is time to replace the accumulator with this reference. Installation is straightforward in the original compartment of the device, with no tools or adapters required.

3. Technical Specifications

Parameter Specification
Reference Cahnos (SKU) 88888305
Original manufacturer reference (OEM) 147-0127-00
Other part numbers documented in the aftermarket 146-0127-00, DR202I, OM11568, B12023, 146-0130-00 (verify the label of the installed battery)
Accumulator type Lithium-ion (Li-ion), rechargeable
Nominal voltage 10.8 V
Nominal capacity 6.6 Ah (6,600 mAh)
Energy 71.28 Wh
Dimensions (according to the commercial datasheet) 120 x 70 x 40 mm (compare against the assembled part)
Approximate weight 0.5 kg
Recharge Automatic with the monitor connected to the mains
Compatibility Spacelabs Medical mCare 300 vital signs monitor; documented aftermarket spare parts for mCare 300D and ELS5
Application ICU, emergency department, operating theatre, hospital ward and in-hospital transport
Presentation 1 unit

Note: the dimensions and weight stated correspond to those declared in the commercial datasheet; as this is a spare part, it is recommended to compare dimensions, connector and cell configuration with the original battery before replacement.

4. Equivalences and Cross-References

Ref. Cahnos 88888305 corresponds to the 10.8 V / 6.6 Ah Li-ion battery for the Spacelabs Medical mCare 300 monitor, which replaces the original device reference 147-0127-00, a code that appears consistently in catalogues and specialist distribution linked to this monitor; in distribution sources the number 146-0127-00 is also documented for the same platform (mCare 300 / ELS5), so the reference marked on the label of the installed battery should be confirmed. Codes DR202I, OM11568, B12023 and 146-0130-00 appear consistently associated with this pack in aftermarket spares.

Spacelabs Medical does not publish an official equivalence table authorising third-party batteries for this reference; the alternatives listed below share chemistry (Li-ion) and capacity window and are classified as comparable by category, not interchangeable 1:1, and voltage, connector, dimensions and housing must be verified before replacement.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Cameron Sino Medical series for Spacelabs mCare300 / mCare300D / ELS5 CS-SPR300MD (also MED-CS-SPR300MD) Comparable by category (not interchangeable 1:1) Li-ion 10.8 V / 7,800 mAh (capacity higher than the 6,600 mAh of this reference), dimensions ≈148.5 x 88.5 x 20.0 mm and ≈610 g; declared as a replacement for 146-0127-00, DR202I, OM11568, B12023 and 146-0130-00 for mCare300, mCare300D and ELS5. Same chemistry and voltage; verify connector and compartment. Confirmed in the battery manufacturer’s datasheet and in authorised distribution.
PBS Battery (Battery Solution) Original pack documented for mCare 300 (Li202S series) Li202S-7800 / Li202S-78A Comparable by category (not interchangeable 1:1) Original pack part number documented for the Spacelabs mCare 300 monitor: Li-ion at 11.1 V (as opposed to 10.8 V for this reference) and capacities of 6,600 / 7,200 / 7,800 mAh, dimensions ≈148.5 x 89.0 x 19.4 mm. Verify the device’s charging electronics before replacement. Battery manufacturer datasheet consulted.
OSI Batteries (Unipower) Replacement for mCare 300 (VSM) 91220 (item B12023) Comparable by category (not interchangeable 1:1) Li-ion 7.8 Ah battery for the Spacelabs mCare 300 vital signs monitor, declared as a replacement for reference 146-0127-00; 5-position connector and smart battery fuel gauge. The distributor’s own datasheet declares 10.8 V in the description and 11.1 V in its specifications table: confirm voltage and housing before replacement. Specialist distributor datasheet consulted.

There is no equivalence table validated by Spacelabs Medical (the equipment manufacturer) that cross-references part number 147-0127-00 with third-party brands; the alternatives listed are comparable by category and must be verified against the technical data sheet and the equipment manual before use. It is recommended to consult the technical department before using this reference in tenders.

5. Selection tips and variants of interest

  • Identify the exact monitor: this 10.8 V / 6.6 Ah battery is the one indicated for the Spacelabs Medical mCare 300 family (and documented in aftermarket spare parts for mCare 300D and ELS5). Do not confuse it with batteries from other monitors of the same brand with different voltage, chemistry or capacity (e.g. the 11.1 V / 7.8 Ah for Qube or the 12 V / 2.7 Ah for UltraView 1030).
  • Verify the reference of the installed battery: check the codes 147-0127-00, 146-0127-00 or other numbering on the battery label before replacing. Always respect the voltage (10.8 V) and Li-ion chemistry; do not use batteries of other chemistry or voltage without validation from the technical service.
  • Replace upon signs of wear: clearly reduced battery life or low battery warnings within a few hours of charging indicate that the battery has reached the end of its useful life.
  • After replacement: leave the monitor connected to the mains to complete the charge and verify that the battery indicator reflects the new status before returning the equipment to clinical service.
  • Orders by reference: always indicate the code 88888305 or the original equipment reference (147-0127-00) to avoid confusion with other batteries in the Spacelabs family.
  • Waste management: deliver the depleted lithium battery to an authorised collection point in accordance with WEEE regulations; do not dispose of it in the general waste container.
  • For mixed fleets: consult our catalogue of batteries for vital signs monitors; we have spare parts for the Spacelabs, Philips, GE HealthCare, Mindray, Nihon Kohden and other families. If in doubt, contact our technical-commercial department indicating the model, serial number and reference of the installed battery.

Additional information

Accumulator type

Lithium-ion (Li-ion), rechargeable

Chemistry

Memory-effect-free Li-ion

Nominal voltage

10.8 V

Capacity

6.6 Ah (6,600 mAh)

Energy

71.28 Wh

Manufacturer reference

147-0127-00 (also documented as 146-0127-00)

Compatibility

Spacelabs Medical mCare 300 vital signs monitor; documented aftermarket spare parts for mCare 300D and ELS5

Dimensions

120 x 70 x 40 mm according to the commercial datasheet (compare against the assembled part)

Weight

≈ 0.5 kg

Rechargeable

Yes; automatic recharging with the monitor connected to the mains

Installation

Direct replacement in the equipment compartment, without tools

Application

ICU, emergency department, operating theatre, hospital ward and in-hospital transport

Maintenance

Maintenance-free; periodic inspection in medical electronics

Other part numbers

146-0127-00, DR202I, OM11568, B12023, 146-0130-00 (verify the label of the installed battery)

Technology

Lithium-ion (Li-ion), rechargeable

Nominal capacity

6.6 Ah (6,600 mAh)

Approximate weight

0.5 kg

Recharge

Automatic with the monitor connected to the mains

Recycling

WEEE (lithium battery)

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Li-ion Battery 10.8 V 6.6 Ah (71.28 Wh) for Spacelabs Medical mCare 300 / mCare 300D / ELS5 Vital Signs Monitor | Replaces 147-0127-00 and 146-0127-00 | Ref. 88888305”

Your email address will not be published. Required fields are marked *