Keeping vital signs monitors always operational is a daily requirement in hospitals, health centres, emergency departments and critical care units. With the original Philips Viridia M3 battery (MFR M3046A) from reference Cahnos 88888266, medical electronics and maintenance services have the appropriate spare part for the monitor’s battery compartment, ensuring that the equipment continues to monitor the patient during intra-hospital transfers, ambulance transport or power supply interruptions. It is the reliable and proven solution your fleet of Philips Viridia monitors needs, with the warranty and technical advice from Cahnos.
2. Technical explanation of the equipment and the battery
The Philips Viridia M3 monitor is a multiparameter monitor from the Viridia platform (bedside and transport) that integrates ECG, SpO₂ pulse oximetry, non-invasive blood pressure and other vital signs monitoring functions. The equipment operates connected to the mains and, in portable mode, powered by its internal rechargeable battery: when disconnected from the mains or during a transfer, the pack takes over the power supply without interrupting monitoring.
The original reference M3046A corresponds to a rechargeable pack with Ni-MH (nickel-metal hydride) chemistry, with a nominal voltage of 12 V and a capacity of 3.85 Ah (3,850 mAh). It is a smart battery with a 5-position connector, automatically rechargeable by the monitor itself while it remains plugged in. Specialist distribution usually expresses this same pack as 4,000 mAh / 48 Wh: the small difference of tenths between 3.85 Ah and 4.00 Ah is common between batches and commercial roundings of the same Ni-MH cell format.
Technical note: although some commercial datasheets describe this pack as lithium-ion, the internal technical documentation and specialist distribution datasheets identify the M3046A as 12 V Ni-MH; it is advisable to always verify the chemistry indicated on the label of the removed pack before replacement.
3. Technical Specifications
| Parameter | Specification |
| Reference Cahnos (SKU) | 88888266 |
| Manufacturer reference | M3046A (MFR) |
| Battery type | Internal rechargeable battery for vital signs monitor |
| Technology | Ni-MH (nickel-metal hydride) |
| Nominal voltage | 12 V |
| Nominal capacity | 3.85 Ah (3,850 mAh); expressed as 4,000 mAh / 48 Wh by the specialist distribution of the M3046A pack |
| Energy | ≈ 48 Wh (according to specialist distribution of the M3046A pack) |
| Dimensions | 149 × 89 × 20.6 mm (specialist distribution reference) |
| Approximate weight | ≈ 0.59 kg (591 g) |
| Connector | 5 positions (smart battery) |
| Rechargeable | Yes, automatically with the monitor connected to the mains |
| Compatibility | Philips Viridia M3 (target); same platform in Viridia M2, M4 and models M3000A, M3015A, M3016A |
| Presentation | 1 unit |
4. Equivalences and Cross-References
Specialist medical battery distribution consistently identifies the M3046A pack from the Viridia platform with several alternative OEM codes from the same brand. The pack attributes (12 V, Ni-MH, 4,000 mAh, format 149 × 89 × 20.6 mm, 5-position connector) are verified identically in the sources that cross-reference these codes.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Philips | Viridia series (12 V Ni-MH pack) | M3056 | Exact reference equivalence (same manufacturer) | Alternative OEM code for the same pack from the Viridia platform; consistently cited as a replacement for the M3046A by specialist distribution. |
| Philips | Viridia series (12 V Ni-MH pack) | NJ1020HP | Exact reference equivalence (same manufacturer) | Same 12 V / 4,000 mAh Ni-MH pack; no documented differences versus the M3046A in distribution sources. |
| Philips | Viridia series (12 V Ni-MH pack) | NJ1020AVP | Exact reference equivalence (same manufacturer) | Same 12 V / 4,000 mAh Ni-MH pack; alternative code verified in the cross-reference of Viridia platform references. |
| Philips | Viridia series (12 V Ni-MH pack) | OM11180-IE | Exact reference equivalence (same manufacturer) | Same pack from the Viridia platform; cited alongside the M3046A in specialist distribution replacement tables. |
| Philips | Viridia series (12 V Ni-MH pack) | DR36AAS | Exact reference equivalence (same manufacturer) | Ni-MH 12 V / 3,800–4,000 mAh pack with smart electronics; code shared with other equipment (e.g. Mediana YM6000 monitor), verify mechanics and connector. |
| CS (replacement pack manufacturer) | Replacement pack for Viridia platform | CS-PHM200MD | Comparable by category (not interchangeable 1:1) | Ni-MH 12 V / 4,000 mAh pack with dimensions and connector equivalent to the OEM; it is not an original Philips part. It also appears as BP-PHM200MD. |
There is no equivalence table validated by the manufacturer (Philips) that officially cross-references these codes with each other; the cross-reference comes from specialist distribution (multiple independent and consistent sources) and must be confirmed with the technical department before use in tendering or scheduled replacement. The same M3046A pack is the one fitted in monitors from the Viridia family (M2, M3, M4) and equipment that uses that format, such as the Colin BP-S510 monitor.
5. Selection tips and variants of interest
- Confirm the exact model: this battery is the one indicated for the Philips Viridia M3 platform and its siblings M2 / M4 and M3000A / M3015A / M3016A. Before ordering, verify the reference and chemistry of the removed battery and the monitor model on its nameplate.
- Do not confuse Philips families: the IntelliVue MP20/MX40 monitors use the 04605A (10.8 V / 3.7 V, Li-ion) and the MP2 uses the M4607A (10.8 V, Li-ion): they are different batteries, not interchangeable with the M3046A, even though they are also Philips monitors.
- Replace upon signs of wear: clearly reduced battery life or low-battery warnings within a few hours of charging indicate the end of the pack’s useful life; preventive replacement every 2 years is the recommended practice in medical electronics.
- After installation: connect the monitor to the mains and allow a full charge cycle to complete before a prolonged session in portable mode; the Viridia’s management system characterises the new pack during the first cycle.
- Storage: if the equipment is to remain unused for more than two months, it is advisable to recharge the pack periodically to avoid the capacity degradation inherent to Ni-MH chemistry.
- Environmental management: deliver the exhausted Ni-MH pack to a collection point in accordance with WEEE regulations; never dispose of it in the general waste container.
- For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department indicating the model, serial number and reference of the installed battery; we will confirm compatibility and a formal quotation.