Description
1. Reliable power for your circulatory assist system
The Maquet Cardiosave Hybrid battery (ref. Cahnos 88881205) is the recommended power replacement for the intra-aortic balloon pump (IABP) circulatory assist system Maquet Cardiosave Hybrid, replacing the original manufacturer reference 0146-00-0097. Designed for haemodynamics laboratories, cardiac operating theatres, ICU and intra-hospital transport, it allows counterpulsation to be maintained without depending on a mains supply: patient transfers, power interruptions or critical situations where the continuity of circulatory assist cannot tolerate pauses. It is a rechargeable lithium-ion cell, ready to install in the device’s battery bays and compatible with the original charger (charging station and Cardiosave console).
2. How this battery works
The Maquet Cardiosave Hybrid is an intra-aortic counterpulsation device that synchronises the inflation and deflation of the balloon with the cardiac cycle to improve coronary flow and reduce left ventricular afterload. To operate without depending on the mains supply, it incorporates two battery bays that accept two interchangeable lithium-ion packs: while one pack powers the device, the second remains charged as a reserve, and the system automatically switches between them. This cell delivers a nominal voltage of 15 V with a capacity of 14.3 Ah, which represents a total energy of 213.6 Wh. Its Li-ion chemistry offers a stable discharge curve and no memory effect. According to Getinge’s official documentation (operation manual and quick battery guide for the Cardiosave), the charging time is approximately 5 hours per pack up to 90% or more of capacity, and the manufacturer recommends replacing the accumulator after 200 complete discharge cycles, at intervals not exceeding 4 years, or when the battery life is less than 60 minutes at 120 beats per minute. The reference 0146-00-0097 is registered in the GUDID/FDA regulatory database in the name of Datascope Corp. (Getinge/Maquet group) as a reusable Li-ion battery pack for the intra-aortic balloon system.
3. Technical Specifications
| Characteristic | Specification |
| Application | Circulatory assist system (IABP) Maquet Cardiosave Hybrid |
| Original manufacturer reference | 0146-00-0097 (Datascope Corp. / Getinge, verified in GUDID) |
| Battery type | Lithium-ion (Li-ion), rechargeable |
| Nominal voltage | 15 V |
| Capacity | 14.3 Ah (14,300 mAh) |
| Energy | 213.6 Wh |
| Number of bays on the device | 2 (accepts two interchangeable packs) |
| Weight-bearing time | Approximately 5 hours per pack up to ≥90% (Getinge documentation) |
| Recommended replacement | After 200 full cycles, max. 4 years, or if battery life is less than 60 min at 120 BPM |
| Approximate dimensions (according to replacement manufacturer) | 185 x 81 x 63.35 mm (verify compartment) |
| Regulatory classification of the device | FDA Class II, DSP code (Intra-aortic balloon and control system), reg. 870.3535 |
| Presentation | Unit |
Note: the voltage, capacity and energy indicated correspond to the declared specification for reference 0146-00-0097. Always verify the compartment, connector and condition of the bay on your unit before replacement.
4. Equivalences and Cross-References
The reference 0146-00-0097 is the original factory code (Datascope Corp., Getinge group) of the Li-ion battery pack for the Maquet Cardiosave Hybrid, confirmed in the GUDID/FDA regulatory database (primary identifier 10607567111988) and in Getinge’s official documentation. The device manufacturer does not publish an official equivalence table authorising third-party batteries for the Cardiosave; the references listed below come from replacement battery manufacturers that declare they replace the 0146-00-0097 and are classified as comparable by category (not 1:1 interchangeable). Before replacement, each of the following must be verified one by one: voltage, capacity, chemistry (Li-ion), connector and compartment dimensions.
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
| Cameron Sino | Medical Series (Maquet Cardiosave) | CS-MAT097MD (also MED-CS-MAT097MD) | Comparable by category (not interchangeable 1:1) | Li-ion 14.3 V / 14,900 mAh; declared as a replacement for the 0146-00-0097 for Cardiosave Hybrid in specialised distribution catalogues; declared dimensions 185 x 81 x 63.35 mm and ≈1,468 g. Nominal voltage (14.3 V vs 15 V) and capacity (14,900 vs 14,300 mAh) differ: verify connector and compartment before replacing. |
| Kingsener | Medical series (Maquet Cardiosave Hybrid / Datascope) | Kingsener 0146-00-0097 | Comparable by category (not interchangeable 1:1) | Li-ion 15 V / 14.3 Ah (213.6 Wh), 100% new condition with declared warranty of 1 to 2 years. Replaces the 0146-00-0097 for the Cardiosave Hybrid (IABP); confirm pack dimensions and compatibility with the device’s original charging station. |
There is no manufacturer-validated equivalence table authorising third-party batteries for reference 0146-00-0097; the references indicated have been cross-checked against battery manufacturer datasheets and specialist distribution catalogues, but substitution must be validated field by field (voltage, capacity, chemistry, connector and dimensions) before use in tenders. Consult the technical department before using this reference in public tenders.
5. Selection tips and variants of interest
Identify the exact model: this battery corresponds to the Maquet Cardiosave Hybrid (IABP) circulatory assist system. Also check the label of the installed pack: the original reference may appear as 0146-00-0097 (Datascope Corp.) and the equipment accepts two interchangeable packs, so it is recommended to always keep a second unit charged as a reserve. Li-ion maintenance: keep the packs charged if the equipment is to remain idle for long periods, respect the charging time of 5 hours per pack and replace the accumulator when the runtime is less than 60 minutes at 120 BPM, after 200 complete cycles or at 4 years, according to Getinge’s official documentation. Do not exchange this battery for packs from other equipment of the same brand without technical validation: each device accepts a specific voltage, capacity and geometry. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, lead times and formalised quotation.





Reviews