We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

GE HealthCare Carescape PDM battery · Li-Ion 11.1 V 1.85 Ah · Manufacturer ref. 2031069-003 (previous 2016989-002) · Ref. Cahnos 88888754

448,00 €

Li-Ion battery 11.1 V / 1.85 Ah for the vital signs monitor and patient data module GE HealthCare Carescape PDM, corresponding to the original factory reference 2031069-003 (previous numbering of the same battery: 2016989-002, also documented for Solar 8000i, Mini Dash and Protransport). This spare part reproduces the specifications of the original part and restores the module’s full autonomy during intra-hospital transfers, ambulance transport or power supply cuts, with automatic recharging while the device remains connected to the mains. Lithium-ion chemistry, no memory effect and high energy density in a compact and lightweight format. Direct installation in the module compartment, without tools. Ref. Cahnos 88888754, price per unit.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888754

Description

1. Commercial Introduction

At Cahnos we offer the replacement 11.1 V / 1.85 Ah lithium-ion battery for the GE HealthCare Carescape PDM patient data module (Ref. Cahnos 88888754, original factory reference MFR 2031069-003). This battery reproduces the specifications of the original part and restores the module’s full autonomy when the equipment is disconnected from the mains: internal transfers, intra-hospital transport, mobile units and power cuts. Available with fast delivery for intensive care, anaesthesia, operating theatre, emergency services, medical electronics companies and monitoring equipment maintenance contracts. Price per unit.

2. Technical explanation of the equipment and the battery

The PDM (Patient Data Module) from the Carescape family is the device that centralises the acquisition of the patient’s vital signs (ECG, saturation, pulse rate, pressure and other parameters) and transmits them to the central station or bedside monitor. To ensure continuity of monitoring when the module is disconnected from the mains or moved with the patient, it incorporates an internal rechargeable battery that acts as a backup power source: while the module remains connected to the mains, the battery stays charged; if the power supply fails or the patient is transferred, the battery automatically takes over the power supply without interrupting monitoring.

This replacement is a lithium-ion (Li-Ion) battery that delivers a nominal voltage of 11.1 V and a capacity of 1.85 Ah (≈21 Wh), with high energy density, low self-discharge, no memory effect and a longer service life than nickel technologies. According to the official GE HealthCare catalogue (GE HealthCare Service Shop), reference 2031069-003 corresponds to the PDM battery used in patient monitoring and anaesthesia systems; authorised distribution and the manufacturer itself also associate it with the Solar 8000i, Mini Dash and Protransport equipment. Replacement is carried out directly in the module compartment, without tools or adaptations.

3. Technical Specifications

Data cross-checked against the official GE part data sheet 2031069-003 (GE HealthCare Service Shop) and authorised technical distribution sources for third-party cross-references.

Parameter Specification
Reference Cahnos (SKU) 88888754
Manufacturer reference (GE HealthCare) 2031069-003 (FRU PDM Battery)
Previous part number of the same battery 2016989-002
Battery type Rechargeable lithium-ion (Li-Ion) battery pack
Nominal voltage 11.1 V
Nominal capacity 1.85 Ah (1,850 mAh)
Approximate energy ≈21 Wh (11.1 V × 1.85 Ah)
Compatibility GE HealthCare Carescape PDM; documented for Solar 8000i, Mini Dash and Protransport (GE source and authorised distribution)
Approximate dimensions (distribution) ≈81 × 59 × 20 mm; verify with the battery removed
Approximate weight (distribution) ≈170 g
Recharge Automatic with the module connected to the mains
Installation Direct replacement in the module compartment, no tools required
Intended use Hospital, ICU, operating theatre, anaesthesia, emergency, mobile units and intra-hospital transport
Presentation 1 unit
Recycling Management in accordance with WEEE regulations

Compatibility note: confirm the exact model of your equipment and the reference printed on the removed battery before replacing. Batteries from other models in the CARESCAPE series are not interchangeable with this battery: the B450 uses ref. 2062895-001 (FLEX-3S2P, 10.8 V / 3.8 Ah) and the B650 / B850 uses ref. 2036984-001 (FLEX-3S3P, 11.1 V / 6 Ah).

4. Equivalences and Cross-References

Reference 2031069-003 is confirmed in the official GE HealthCare parts catalogue (GE HealthCare Service Shop) as a rechargeable 11.1 V / 1.85 Ah Li-Ion battery for the Carescape PDM patient data module, with the previous part number 2016989-002 of the same battery documented by the manufacturer and authorised distribution. GE HealthCare does not publish an official cross-reference table with third-party batteries; the market alternatives indicated have been cross-checked against battery manufacturer data sheets and authorised technical distribution, share Li-Ion chemistry and are considered comparable at category level, not 1:1 interchangeable. Before replacing, validation must be carried out field by field (voltage, capacity, dimensions, connector and SMBus protocol if applicable).

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
GE HealthCare (same manufacturer) PDM battery for the Carescape PDM (Li-Ion 11.1 V / 1.85 Ah) 2016989-002 Exact reference equivalence (same manufacturer) Previous numbering of the same original part documented by GE HealthCare and authorised distribution; identical chemistry, voltage and capacity. Confirm the batch label before ordering.
Cameron Sino (aftermarket replacement) Battery for GE Dash Mini / B650 / B850 / Carescape PDM CS-GMB650MD Comparable by category (not interchangeable 1:1) Li-Ion 11.1 V / 1,850 mAh, built to replace 2031069-003, 2016989-002, 2016989-003, M2820, AMED3709, 6291-A and DR203 (source: manufacturer’s data sheet and authorised distribution). Same chemistry, voltage and nominal capacity; check connector and compartment fit.
OSI Batteries (Unipower) Biomedical battery PDM Marquette / GE B11811 Comparable by category (not interchangeable 1:1) Li-Ion with nominal voltage of 10.8 V and capacity of 2.05 Ah; replaces OEM parts 2031069-003 and 2016989-002. Voltage and capacity slightly different from the original part; validate charging electronics, connector and dimensions.
R&D Batteries (aftermarket replacement) Battery for PDM, Solar 8000i and Mini Dash 6291-A / 6291-A-3 Comparable by category (not interchangeable 1:1) Li-Ion 11.1 V / 1.8 Ah, documented for 2031069-003 and 2016989-002; its cross-references include Anybattery 8388, Cables and Sensors 11144, Cameron Sino CS-GMB650MD, Interstate MED3709, NCE N1303 and OSI B11811. Same nominal specifications; validate connector and dimensions.
Energy+ Batteries / Fedco (smart series) SMBus battery for GE PDM, Solar 8000i and Protransport DR203 / SM203 Comparable by category (not interchangeable 1:1) Li-Ion 11.1 V / 2,600 mAh with smart battery SMBus protocol; replaces 2016989-002 and 2031069-003 (source: and Energy+ Batteries). Capacity higher than the original (up to ≈40% more autonomy); validate SMBus communications, connector and compartment fit.

There is no equivalence table validated by the manufacturer (GE HealthCare) that cross-references part number 2031069-003 with third-party batteries; consult the technical department before using in a tender.

5. Selection tips and variants of interest

Identify the module: this battery corresponds to the GE HealthCare Carescape PDM patient data module. If your device is from another series of the CARESCAPE family it is not interchangeable with this reference: the B450 uses battery 2062895-001 (FLEX-3S2P, 10.8 V / 3.8 Ah, Ref. Cahnos 88881157) and the B650 / B850 uses 2036984-001 (FLEX-3S3P, 11.1 V / 6 Ah, Ref. Cahnos 88888819).

Check the label: confirm the stamped reference (2031069-003 or the previous numbering 2016989-002), as well as voltage (11.1 V), capacity (1.85 Ah) and Li-Ion chemistry before replacing. Do not use batteries of another voltage even if the connector looks similar.

Safe replacement: carry out the change with the module switched off; after assembly, leave the device connected to the mains to complete the charge and check that the battery indicator reflects the new state before returning it to service.

Wear symptoms: clearly reduced autonomy, premature low-battery warnings or excessive charging times indicate that the Li-Ion battery has reached the end of its useful life (typically 500-800 cycles depending on use).

Other GE HealthCare family references in catalogue: we have spare parts for GE monitors, e.g. ref. 88888819 for CARESCAPE B650 (11.1 V / 6 Ah), ref. 88881157 for B450, ref. 88888214 for Dash 3000-4000, ref. 88881004 for Dash 2500 or ref. 88888116 for CardioCap 5. If you manage a mixed fleet, consult our catalogue of vital signs monitor batteries.

Environmental management: deliver the exhausted battery to a specialised collection point (WEEE); do not place it in the general waste container. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department indicating model, serial number and reference of the installed battery; we will confirm compatibility before formalising the order.

Additional information

Technology

Lithium-ion (Li-Ion), rechargeable

Nominal voltage

11.1 V

Capacity

1.85 Ah (1,850 mAh)

Approximate energy

≈21 Wh (11.1 V × 1.85 Ah)

Manufacturer reference

2031069-003 (GE HealthCare, FRU PDM Battery); previous part number of the same battery: 2016989-002

Other documented part numbers

2016989-002

Operating temperature

0 °C to 45 °C

Compatibility

GE HealthCare Carescape PDM; documented for Solar 8000i, Mini Dash and Protransport (GE source and authorised distribution)

Rechargeable

Yes; automatic recharging with the module connected to the mains

Regulatory standard

UL 1642, UL 60950-1, UL 2054, IEC 62133, RoHS (declared by GE HealthCare)

Installation

Direct replacement in the module compartment, no tools required

Intended use

Hospital, ICU, operating theatre, anaesthesia, emergency, mobile units and intra-hospital transport

Recycling

RAEE/WEEE

Equipment manufacturer

GE HealthCare

Product type

Internal rechargeable battery for patient data module / vital signs monitor

Dimensions

≈81 × 59 × 20 mm according to authorised distribution; verify with the battery removed

Approximate weight

≈170 g

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “GE HealthCare Carescape PDM battery · Li-Ion 11.1 V 1.85 Ah · Manufacturer ref. 2031069-003 (previous 2016989-002) · Ref. Cahnos 88888754”

Your email address will not be published. Required fields are marked *