Description
1. Reliable power for your Stryker 4115 surgical motor
At Cahnos we offer you the rechargeable battery for the Stryker 4115 surgical motor (Ref. Cahnos 88889207), corresponding to the original manufacturer reference 4115000000. It is a nickel-cadmium (Ni-Cd) rechargeable battery with 9.6 V and 1.3 Ah that allows you to work with complete freedom of movement in the operating theatre, without power cables or dependence on the mains power.
It is the ideal solution for medical electronics services, operating theatre maintenance, traumatology and hospital purchasing that need to replace the battery of their Stryker 4115 series drills with a reliable, traceable part at a very competitive cost compared to the official replacement.
2. Technical explanation
The Stryker 4115 belongs to the family of cordless surgical motors (Cordless Driver, STR-5000 series) from Stryker Instruments, commonly used in orthopaedic and large bone surgery (drilling, reaming and screwing) together with the System 4 and System 5 handpieces (4103, 4106, 4108, 4203, 4205, 4206 and 4208). The motor is powered by a rechargeable battery pack attached to the instrument body: while the battery is charged, the unit delivers constant torque and rotation speed without interfering with the surgeon’s ergonomics.
This battery uses nickel-cadmium (Ni-Cd) chemistry, 9.6 V nominal voltage and 1.3 Ah capacity, with a total energy of 12.48 Wh and an approximate weight of 0.5 kg. When the motor’s battery life is noticeably reduced or the unit does not maintain torque during long procedures, it is time to replace the battery with this reference. Installation is direct in the original motor compartment, without tools or adaptations, and it is compatible with the chargers of the Stryker 4115 family.
3. Technical Specifications
Replaces the original reference 4115000000 with the same performance and compatibility as the pack supplied with the new unit.
| Parameter | Specification |
|---|---|
| Application | Stryker 4115 cordless surgical motor / drill (STR-5000 series; System 4 and System 5 handpieces: 4103, 4106, 4108, 4203, 4205, 4206 and 4208) |
| Original manufacturer reference | 4115 / 4115000000 |
| Reference Cahnos (SKU) | 88889207 |
| Battery type | Rechargeable battery |
| Technology | Nickel-cadmium (Ni-Cd) |
| Nominal voltage | 9.6 V |
| Capacity | 1.3 Ah (1300 mAh) |
| Energy | 12.48 Wh |
| Approximate weight | 0.5 kg |
| Rechargeable | Yes (Stryker 4115 family chargers) |
| Use | Power supply for surgical drills and motors in the operating theatre |
| Presentation | 1 unit |
Note: reference 4115000000 corresponds to a single battery pack (unit). Always check the reference printed on the removed battery before placing the order.
4. Equivalences and Cross-References
The original reference 4115 (4115000000) is the Ni-Cd pack of 9.6 V / 1.3 Ah that Stryker installs in its 4115 series cordless motors (STR-5000), used with the System 4 and System 5 handpieces. The third-party alternatives listed below have been cross-checked against battery manufacturer data sheets and specialised distribution (R&D Batteries, OSI Batteries, NCE Empowering Safety, BatteryTex, PartsSource) and are classified as comparable by category, not 1:1 interchangeable: they share chemistry (Ni-Cd), voltage (9.6 V) and compatibility with the Stryker 4115, but come from independent manufacturers and may vary in declared capacity (1.25 Ah versus 1.3 Ah), format (full versus insert) or service conditions (reconstruction with previous core).
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| R&D Batteries | Stryker Instruments 4115 (STR-5000) – Rebuilt with housing | 5982-A (alias 5982) | Comparable by category (not interchangeable 1:1) | Replacement rebuilt/reprogrammed with new housing, Ni-Cd 9.6 V / 1.25 Ah (capacity slightly lower than the original); consistently documented in several specialised sources (R&D Batteries, BatteryTex, PartsSource) with cross-references Anybattery 7212 and OSI STR-5000. |
| OSI Batteries (Unipower) | Stryker 4115 Battery Equivalent | STR-5000 | Comparable by category (not interchangeable 1:1) | New biomedical replacement battery for Stryker 4115, Ni-Cd 9.6 V / 1.25 Ah (OEM part 4115); verify connector and compartment dimensions before replacing. |
| OSI Batteries (Unipower) | Stryker 4115 Battery Insert | B11064 | Comparable by category (not interchangeable 1:1) | Insert/cell only Ni-Cd 9.6 V / 1.25 Ah: requires reusing the original housing and connector (previous core) for assembly. It is not a complete 1:1 replacement. |
| NCE Empowering Safety | Stryker 4115 (STR-5000) – Rebuilt with housing | N4115RF | Comparable by category (not interchangeable 1:1) | Reconstruction with housing and reprogramming, Ni-Cd 9.6 V / 1.25 Ah (0.8 lb); appears with the alias 5982 in the battery manufacturer’s data sheet. |
There is no equivalence table validated by the device manufacturer (Stryker) that authorises third-party packs for reference 4115000000 or that cross-references this battery with motors from other manufacturers (e.g. De Soutter, Zimmer, Conmed); the above alternatives come from battery manufacturers and specialised distribution and are offered as comparable by category. Consult the technical department before use in tenders.
5. Selection tips and variants of interest
Identify the exact reference: check the code 4115 / 4115000000 on the label of the removed battery. Always order by reference (SKU Cahnos 88889207) to avoid confusion with other batteries in the Stryker family.
Do not confuse with other variants in the family: the Stryker batteries 4112 (9.6 V / 0.6 Ah Ni-Cd, Ref. Cahnos 88889208), 4212 (9.6 V / 0.6 Ah), 4126 (9.6 V / 1.2 Ah), 6126 (9.6 V / 2 Ah Ni-MH), 6212 (9.6 V / 1.3 Ah Li-Ion) or 7126/7222 (10.8 V Li-Ion) belong to other platforms, with different chemistry, capacity or voltage, and are not interchangeable with that of the 4115.
Ni-Cd battery maintenance: avoid repeated deep discharges, recharge the battery when the motor loses power and do not store it fully discharged to extend its service life.
Replace upon signs of wear: clearly reduced runtime or loss of torque during long procedures indicate that the battery has reached the end of its service life.
Mixed fleets and institutional orders: if you manage Stryker motor parks from several series or need volume pricing, contact our technical-commercial department to confirm compatibility and a formal quotation.